{"id":4067,"date":"2025-04-22T13:58:51","date_gmt":"2025-04-22T05:58:51","guid":{"rendered":"https:\/\/www.leakagetester.com\/?page_id=4067"},"modified":"2025-04-22T14:46:01","modified_gmt":"2025-04-22T06:46:01","slug":"iso-8871-5","status":"publish","type":"page","link":"https:\/\/www.leakagetester.com\/da\/standards\/iso-8871-5\/","title":{"rendered":"ISO 8871-5"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"4067\" class=\"elementor elementor-4067\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-40854497 e-con-full e-flex e-con e-parent\" data-id=\"40854497\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-7b6e2650 e-con-full e-flex e-con e-child\" data-id=\"7b6e2650\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1ed62b75 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"1ed62b75\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 8871-5<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-649c5ca3 e-con-full e-flex e-con e-child\" data-id=\"649c5ca3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-528d414f elementor-widget elementor-widget-heading\" data-id=\"528d414f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h5 class=\"elementor-heading-title elementor-size-default\">Elastomere dele til parenterale l\u00e6gemidler og til udstyr til farmaceutisk brug<br>Del 5: Funktionelle krav og afpr\u00f8vning<\/h5>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4227f1f3 elementor-tablet-align-center elementor-mobile-align-center elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-button\" data-id=\"4227f1f3\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:200}\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/da\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Anmod om et tilbud<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7f37671f e-flex e-con-boxed e-con e-parent\" data-id=\"7f37671f\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-7479e6a9 e-con-full e-flex e-con e-child\" data-id=\"7479e6a9\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c1f01b8 elementor-widget elementor-widget-heading\" data-id=\"2c1f01b8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Standardoversigt<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a7ff4e2 elementor-widget elementor-widget-text-editor\" data-id=\"a7ff4e2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Opretholdelse af steriliteten af parenterale l\u00e6gemidler er et kritisk problem i den farmaceutiske industri og industrien for medicinsk udstyr. <strong data-start=\"519\" data-end=\"533\">ISO 8871-5<\/strong> giver en struktureret testmetode til vurdering af den funktionelle integritet af elastomeriske lukninger, der bruges med injektionsh\u00e6tteglas. Specifikt beskriver den procedurer til at bestemme <strong data-start=\"713\" data-end=\"749\">h\u00e6tteglas gummilukning selvforseglende<\/strong> ydeevne og t\u00e6thed af lukke-vial-gr\u00e6nsefladen under simulerede stressforhold.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-58d7dfdf e-con-full e-flex e-con e-child\" data-id=\"58d7dfdf\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4aba77f5 elementor-widget elementor-widget-image\" data-id=\"4aba77f5\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.astm.org\/d3078-02r21e01.html\" target=\"_blank\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"200\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp\" class=\"attachment-medium size-medium wp-image-4076\" alt=\"ISO 8871-5\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp 600w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5-18x6.webp 18w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-38d9a2dc e-flex e-con-boxed e-con e-parent\" data-id=\"38d9a2dc\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-22b1040c e-con-full e-flex e-con e-child\" data-id=\"22b1040c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c1b4a01 elementor-widget elementor-widget-heading\" data-id=\"2c1b4a01\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Standard beskrivelse<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2dbe846b elementor-widget elementor-widget-text-editor\" data-id=\"2dbe846b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"1055\" data-end=\"1447\"><strong data-start=\"1055\" data-end=\"1069\">ISO 8871-5<\/strong>, med titlen <em data-start=\"1078\" data-end=\"1200\">\u201cElastomere dele til parenterale l\u00e6gemidler og til udstyr til farmaceutisk brug - Del 5: Funktionelle krav og pr\u00f8vning\u201d<\/em>, definerer kravene til ydeevne og testmetoder for gummipropper, der anvendes i sterile medicinske beholdere. Disse propper uds\u00e6ttes ofte for gentagne indstik af kanyler og skal bevare beholderens integritet ved at genforsegle effektivt.<\/p><p class=\"\" data-start=\"1449\" data-end=\"1719\">Fejl i <strong data-start=\"1460\" data-end=\"1478\">l\u00e6kagetest af h\u00e6tteglas<\/strong> resultater kan kompromittere steriliteten med risiko for kontaminering, forkert dosering eller forringet effekt. Derfor f\u00f8lger producenter og fagfolk inden for kvalitetskontrol denne standard n\u00f8je for at overholde lovgivningen og sikre patientsikkerheden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-346b4bef e-con-full e-flex e-con e-child\" data-id=\"346b4bef\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7704d43d elementor-widget elementor-widget-image\" data-id=\"7704d43d\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1020\" height=\"578\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/Bottle-Vacuum-Leak-Test--1400x793.webp\" class=\"attachment-large size-large wp-image-3757\" alt=\"Flaskevakuuml\u00e6kagetest\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/Bottle-Vacuum-Leak-Test--1400x793.webp 1400w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/Bottle-Vacuum-Leak-Test--706x400.webp 706w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/Bottle-Vacuum-Leak-Test--768x435.webp 768w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/Bottle-Vacuum-Leak-Test--1536x870.webp 1536w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/Bottle-Vacuum-Leak-Test--18x10.webp 18w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/Bottle-Vacuum-Leak-Test-.webp 1617w\" sizes=\"(max-width: 1020px) 100vw, 1020px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9ee25e2 e-flex e-con-boxed e-con e-parent\" data-id=\"9ee25e2\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-9a921cd e-con-full e-flex e-con e-child\" data-id=\"9a921cd\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5f08225 elementor-widget elementor-widget-heading\" data-id=\"5f08225\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">L\u00e6kagetest af h\u00e6tteglas, maskine til l\u00e6kagetest af h\u00e6tteglas og procedure forklaret<br>Test af selvforsegling og indtr\u00e6ngning af farvestof i h\u00e6tteglas med gummilukning<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9c9adad elementor-widget elementor-widget-text-editor\" data-id=\"9c9adad\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"1859\" data-end=\"2099\">Selvforseglingsevne er en af de mest kritiske egenskaber, der vurderes under ISO 8871-5. Den <strong data-start=\"1950\" data-end=\"1986\">h\u00e6tteglas gummilukning selvforseglende<\/strong> Testen simulerer gentagne n\u00e5lestik og evaluerer, om lukningen lukker effektivt igen under vakuumtryk.<\/p><p class=\"\" data-start=\"2101\" data-end=\"2189\">I <strong>Bilag C og D i ISO 8871-5<\/strong>, to prim\u00e6re <strong data-start=\"2145\" data-end=\"2174\">procedurer for l\u00e6kagetest af h\u00e6tteglas<\/strong> er specificeret:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6cb75bb e-n-tabs-mobile elementor-widget elementor-widget-n-tabs\" data-id=\"6cb75bb\" data-element_type=\"widget\" data-settings=\"{&quot;tabs_justify_horizontal&quot;:&quot;start&quot;,&quot;horizontal_scroll&quot;:&quot;disable&quot;}\" data-widget_type=\"nested-tabs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-tabs\" data-widget-number=\"113997243\" aria-label=\"Tabs. Open items with Enter or Space, close with Escape and navigate using the Arrow keys.\">\n\t\t\t<div class=\"e-n-tabs-heading\" role=\"tablist\">\n\t\t\t\t\t<button id=\"e-n-tab-title-1139972431\" class=\"e-n-tab-title\" aria-selected=\"true\" data-tab-index=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"e-n-tab-content-1139972431\" style=\"--n-tabs-title-order: 1;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tTestprocedure for selvforsegling:\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-1139972432\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-1139972432\" style=\"--n-tabs-title-order: 2;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tDye Solution Tightness Procedure (uden piercing):\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t\t<\/div>\n\t\t\t<div class=\"e-n-tabs-content\">\n\t\t\t\t<div id=\"e-n-tab-content-1139972431\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-1139972431\" data-tab-index=\"1\" style=\"--n-tabs-title-order: 1;\" class=\"e-active elementor-element elementor-element-4a09704 e-con-full e-flex e-con e-child\" data-id=\"4a09704\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5218dd8 elementor-widget elementor-widget-text-editor\" data-id=\"5218dd8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol data-start=\"2226\" data-end=\"2729\"><li class=\"\" data-start=\"2226\" data-end=\"2275\"><p class=\"\" data-start=\"2229\" data-end=\"2275\">Fyld hvert rent h\u00e6tteglas med partikelfrit vand.<\/p><\/li><li class=\"\" data-start=\"2276\" data-end=\"2336\"><p class=\"\" data-start=\"2279\" data-end=\"2336\">Forsegl h\u00e6tteglasset med lukninger og krympeh\u00e6tter i henhold til ISO 8362.<\/p><\/li><li class=\"\" data-start=\"2337\" data-end=\"2441\"><p class=\"\" data-start=\"2340\" data-end=\"2441\">Brug friske hypodermiske n\u00e5le til at stikke hul p\u00e5 hver gummiprop <strong data-start=\"2399\" data-end=\"2411\">10 gange<\/strong>, med forskellige positioner hver gang.<\/p><\/li><li class=\"\" data-start=\"2442\" data-end=\"2500\"><p class=\"\" data-start=\"2445\" data-end=\"2500\">Neds\u00e6nk h\u00e6tteglassene i <strong data-start=\"2466\" data-end=\"2499\">1 g\/L methylenbl\u00e5 opl\u00f8sning<\/strong>.<\/p><\/li><li class=\"\" data-start=\"2501\" data-end=\"2598\"><p class=\"\" data-start=\"2504\" data-end=\"2598\">Anbring de neds\u00e6nkede h\u00e6tteglas i en <strong data-start=\"2534\" data-end=\"2552\">Vakuumkammer<\/strong> og reducer trykket med 27 kPa i 10 minutter.<\/p><\/li><li class=\"\" data-start=\"2599\" data-end=\"2669\"><p class=\"\" data-start=\"2602\" data-end=\"2669\">Genopret det atmosf\u00e6riske tryk, og hold det neds\u00e6nket i yderligere 30 minutter.<\/p><\/li><li class=\"\" data-start=\"2670\" data-end=\"2729\"><p class=\"\" data-start=\"2673\" data-end=\"2729\">Skyl og inspic\u00e9r visuelt for bl\u00e5t farvestof inde i h\u00e6tteglasset.<\/p><\/li><\/ol><p class=\"\" data-start=\"2731\" data-end=\"2824\">Denne test afg\u00f8r, om lukningen bevarer sin selvforseglende evne efter gentagen brug.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-1139972432\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-1139972432\" data-tab-index=\"2\" style=\"--n-tabs-title-order: 2;\" class=\"elementor-element elementor-element-1f65e67 e-con-full e-flex e-con e-child\" data-id=\"1f65e67\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8d828dd elementor-widget elementor-widget-text-editor\" data-id=\"8d828dd\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"2885\" data-end=\"3080\">Dette evaluerer integriteten af <strong data-start=\"2921\" data-end=\"2944\">System til lukning af h\u00e6tteglas<\/strong> uden forudg\u00e5ende punktering. H\u00e6tteglas forberedes, forsegles, neds\u00e6nkes i farvestof og vakuumtrykkes p\u00e5 samme m\u00e5de, hvorefter de inspiceres for indtr\u00e6ngen af farvestof.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fed1035 e-flex e-con-boxed e-con e-parent\" data-id=\"fed1035\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-7873f87 e-con-full e-flex e-con e-child\" data-id=\"7873f87\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-918ea08 e-con-full e-flex e-con e-child\" data-id=\"918ea08\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3f376ab elementor-widget__width-initial elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"3f376ab\" data-element_type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><a href=\"https:\/\/www.leakagetester.com\/da\/lt-02-leak-tester\/\" target=\"_blank\" tabindex=\"-1\"><img decoding=\"async\" width=\"120\" height=\"92\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/10\/LT-02-Vacuum-Leak-Tester.webp\" class=\"attachment-full size-full wp-image-2099\" alt=\"\" \/><\/a><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\"><a href=\"https:\/\/www.leakagetester.com\/da\/lt-02-leak-tester\/\" target=\"_blank\">LT-02 L\u00e6kagetester<\/a><\/h3><p class=\"elementor-image-box-description\">Den f\u00f8rste generation af automatisk l\u00e6kagetester designet af CELL Instruments, som er de mest solgte enheder indtil videre.<\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b584e4d elementor-widget__width-initial elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"b584e4d\" data-element_type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><a href=\"https:\/\/www.leakagetester.com\/da\/lt-03-leak-tester\/\" target=\"_blank\" tabindex=\"-1\"><img loading=\"lazy\" decoding=\"async\" width=\"120\" height=\"94\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/10\/LT-03-leak-tester.webp\" class=\"attachment-full size-full wp-image-2095\" alt=\"LT-03 l\u00e6kagetester Lille\" \/><\/a><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\"><a href=\"https:\/\/www.leakagetester.com\/da\/lt-03-leak-tester\/\" target=\"_blank\">LT-03 L\u00e6kagetester<\/a><\/h3><p class=\"elementor-image-box-description\">Den seneste autol\u00e6kagetester, der stadig er under udvikling, med avanceret kontrolsystem, display og valgfri udskrivning og softwarefunktioner.<\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3384222 e-con-full e-flex e-con e-child\" data-id=\"3384222\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-705671e elementor-widget elementor-widget-heading\" data-id=\"705671e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test udstyr<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d765a06 elementor-widget elementor-widget-text-editor\" data-id=\"d765a06\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"3140\" data-end=\"3378\">N\u00f8jagtig udf\u00f8relse af ISO 8871-5 kr\u00e6ver konsekvent trykregulering, pr\u00e6cis timing og p\u00e5lidelig forsegling. Cell Instruments anbefaler<strong data-start=\"3283\" data-end=\"3311\">\u00a0L\u00e6kagetester til h\u00e6tteglas<\/strong>, designet specielt til at opfylde ISO-standarder, herunder ISO 8871-5.<\/p><p class=\"\" data-start=\"3380\" data-end=\"3393\"><strong>Vigtige funktioner:<\/strong><\/p><ul><li data-start=\"3396\" data-end=\"3449\">Automatisk trykregulering (27 kPa under atmosf\u00e6risk)<\/li><li data-start=\"3396\" data-end=\"3449\">Pr\u00e6cise tidsfunktioner<\/li><li data-start=\"3396\" data-end=\"3449\">Kompatibel med 13 mm og 20 mm h\u00e6tteglas-lukkesystemer<\/li><li data-start=\"3396\" data-end=\"3449\">Velegnet til b\u00e5de selvforseglende og farveindtr\u00e6ngende metoder<\/li><\/ul><p class=\"\" data-start=\"3591\" data-end=\"3775\">Med automatisering og konsekvens kan dette <strong data-start=\"3629\" data-end=\"3658\">maskine til l\u00e6kagetest af h\u00e6tteglas<\/strong> reducerer operat\u00f8rfejl og sikrer repeterbarhed - n\u00f8glen til at overholde lovgivningen og sikre produktsikkerheden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-897aaf5 e-flex e-con-boxed e-con e-parent\" data-id=\"897aaf5\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-23d08cc elementor-widget elementor-widget-heading\" data-id=\"23d08cc\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Anvendelser p\u00e5 tv\u00e6rs af medicinske og farmaceutiske industrier<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-48e4aa6 elementor-widget elementor-widget-text-editor\" data-id=\"48e4aa6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"3844\" data-end=\"3899\">De <strong data-start=\"3848\" data-end=\"3866\">l\u00e6kagetest af h\u00e6tteglas<\/strong> under ISO 8871-5 er afg\u00f8rende for:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-32a66fc e-con-full e-flex e-con e-child\" data-id=\"32a66fc\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bc8b02f elementor-widget__width-initial elementor-widget elementor-widget-heading\" data-id=\"bc8b02f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Injicerbare l\u00e6gemidler med flere doser<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cf25ff0 elementor-widget__width-initial elementor-widget elementor-widget-heading\" data-id=\"cf25ff0\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Beholdere til vacciner<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0ca050f elementor-widget__width-initial elementor-widget elementor-widget-heading\" data-id=\"0ca050f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Indpakning af IV-medicin<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6aebdd4 elementor-widget__width-initial elementor-widget elementor-widget-heading\" data-id=\"6aebdd4\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Diagnostiske h\u00e6tteglas<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8c1e6fc elementor-widget elementor-widget-text-editor\" data-id=\"8c1e6fc\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"3997\" data-end=\"4155\"><strong data-start=\"3997\" data-end=\"4026\">Ingeni\u00f8rer i kvalitetskontrol<\/strong>, <strong data-start=\"4028\" data-end=\"4046\">R&amp;D-forskere<\/strong>, og <strong data-start=\"4052\" data-end=\"4072\">regulatoriske teams<\/strong> er afh\u00e6ngige af disse tests for at validere beholderens integritet, f\u00f8r den kommer p\u00e5 markedet.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-75d00f67 e-con-full e-flex e-con e-parent\" data-id=\"75d00f67\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6d8146b5 elementor-widget__width-inherit elementor-widget elementor-widget-heading\" data-id=\"6d8146b5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Bedste praksis for implementering af ISO 8871-5<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-68472fc8 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"68472fc8\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">For at v\u00e6re helt p\u00e5 linje med ISO 8871-5:<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4781572a animated-slow elementor-widget-divider--view-line elementor-invisible elementor-widget elementor-widget-divider\" data-id=\"4781572a\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;}\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d671e1c elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"d671e1c\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul data-start=\"4241\" data-end=\"4547\"><li class=\"\" data-start=\"4241\" data-end=\"4299\"><p class=\"\" data-start=\"4243\" data-end=\"4299\">Brug ISO 8362-kompatible h\u00e6tteglas, lukninger og krympeforseglinger.<\/p><\/li><li class=\"\" data-start=\"4300\" data-end=\"4354\"><p class=\"\" data-start=\"4302\" data-end=\"4354\">S\u00f8rg for rene og partikelfrie testmilj\u00f8er.<\/p><\/li><li class=\"\" data-start=\"4355\" data-end=\"4432\"><p class=\"\" data-start=\"4357\" data-end=\"4432\">Undg\u00e5 overfladeaktive stoffer i methylenbl\u00e5-opl\u00f8sning for at undg\u00e5 misvisende resultater.<\/p><\/li><li class=\"\" data-start=\"4433\" data-end=\"4471\"><p class=\"\" data-start=\"4435\" data-end=\"4471\">Kalibr\u00e9r vakuumkamre regelm\u00e6ssigt.<\/p><\/li><li class=\"\" data-start=\"4472\" data-end=\"4547\"><p class=\"\" data-start=\"4474\" data-end=\"4547\">Registrer alle inspektionsdata i henhold til standardens dokumentationskrav.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4828799 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"4828799\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Cell Instruments leverer ikke kun udstyr, men ogs\u00e5 <strong data-start=\"4603\" data-end=\"4625\">teknisk tr\u00e6ning<\/strong>, <strong data-start=\"4627\" data-end=\"4655\">Tilpassede testl\u00f8sninger<\/strong>, og <strong data-start=\"4661\" data-end=\"4684\">Automatiseringstjenester<\/strong> for at hj\u00e6lpe laboratorier og producenter med at udf\u00f8re ISO-kompatible tests effektivt.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-563ef868 e-con-full e-flex e-con e-parent\" data-id=\"563ef868\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6a7ad6cf elementor-widget elementor-widget-heading\" data-id=\"6a7ad6cf\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Ofte stillede sp\u00f8rgsm\u00e5l om ISO 8871-5<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7333fe2d e-con-full e-flex e-con e-child\" data-id=\"7333fe2d\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dd759c2 elementor-widget elementor-widget-n-accordion\" data-id=\"dd759c2\" data-element_type=\"widget\" data-settings=\"{&quot;max_items_expended&quot;:&quot;multiple&quot;,&quot;default_state&quot;:&quot;expanded&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accordeon. \u00c5bn links med Enter eller Space, luk med Escape, og naviger med piletasterne.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2320\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-2320\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><h3 class=\"e-n-accordion-item-title-text\"> 1. Hvad tester ISO 8871-5 for? <\/h3><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2320\" class=\"elementor-element elementor-element-e471aee e-con-full e-flex e-con e-child\" data-id=\"e471aee\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7b578c7 elementor-widget elementor-widget-text-editor\" data-id=\"7b578c7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"5395\" data-end=\"5545\">ISO 8871-5 evaluerer selvforseglingen og forseglingsintegriteten af elastomeriske lukninger, der anvendes i farmaceutiske h\u00e6tteglas.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2321\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2321\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><h3 class=\"e-n-accordion-item-title-text\"> 2. Hvordan fungerer proceduren for l\u00e6kagetest af h\u00e6tteglas? <\/h3><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2321\" class=\"elementor-element elementor-element-7ce5868 e-con-full e-flex e-con e-child\" data-id=\"7ce5868\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c9878c6 elementor-widget elementor-widget-text-editor\" data-id=\"c9878c6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"5547\" data-end=\"5731\">Det indeb\u00e6rer gentagne n\u00e5lestik i lukninger, neds\u00e6nkning i farvestof og uds\u00e6ttelse for vakuum for at opdage l\u00e6kager gennem visuel inspektion.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2322\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2322\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><h3 class=\"e-n-accordion-item-title-text\"> 3. Hvorfor er det vigtigt, at h\u00e6tteglassets gummilukning er selvforseglende? <\/h3><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2322\" class=\"elementor-element elementor-element-dcfefc8 e-con-full e-flex e-con e-child\" data-id=\"dcfefc8\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-72b4879 elementor-widget elementor-widget-text-editor\" data-id=\"72b4879\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"5733\" data-end=\"5900\">Det sikrer, at h\u00e6tteglasset forbliver sterilt efter flere punkteringer, is\u00e6r i flerdosisbeholdere.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2323\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2323\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><h3 class=\"e-n-accordion-item-title-text\"> 4. Hvilket udstyr er n\u00f8dvendigt for at udf\u00f8re test i henhold til ISO 8871-5? <\/h3><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2323\" class=\"elementor-element elementor-element-0bfbdd9 e-flex e-con-boxed e-con e-child\" data-id=\"0bfbdd9\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-34a8313 elementor-widget elementor-widget-text-editor\" data-id=\"34a8313\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"5902\" data-end=\"6160\">Du skal bruge ISO 8362-kompatible h\u00e6tteglas og propper, metylenbl\u00e5t farvestof, kanyler og et vakuumkammer. A <strong data-start=\"6090\" data-end=\"6119\">maskine til l\u00e6kagetest af h\u00e6tteglas<\/strong> som LSSD-01 forenkler processen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2324\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2324\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><h3 class=\"e-n-accordion-item-title-text\"> 5. Kan Cell Instruments hj\u00e6lpe med automatisering og tr\u00e6ning til disse tests? <\/h3><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2324\" class=\"elementor-element elementor-element-d9b9e08 e-flex e-con-boxed e-con e-child\" data-id=\"d9b9e08\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ccffa35 elementor-widget elementor-widget-text-editor\" data-id=\"ccffa35\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"flex max-w-full flex-col grow\"><div class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+&amp;]:mt-5\" dir=\"auto\" data-message-author-role=\"assistant\" data-message-id=\"ac04b2fb-b909-4342-bffc-6922592acb69\" data-message-model-slug=\"gpt-4o\"><div class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[3px]\"><div class=\"markdown prose dark:prose-invert w-full break-words light\"><p class=\"\" data-start=\"6162\" data-end=\"6381\">Ja, det g\u00f8r vi. Cell Instruments tilbyder systemer, der kan tilpasses, automatiseringsopgraderinger og ekspertuddannelse for at hj\u00e6lpe kunder med at opfylde ISO-testkrav.<\/p><\/div><\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3a2b679a e-flex e-con-boxed e-con e-parent\" data-id=\"3a2b679a\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-38014124 elementor-widget elementor-widget-heading\" data-id=\"38014124\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Leder du efter p\u00e5lideligt ISO 8871-5 udstyr til l\u00e6kagesporing af h\u00e6tteglas?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-53b530f2 elementor-widget elementor-widget-text-editor\" data-id=\"53b530f2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0G\u00e5 ikke glip af chancen for at optimere dine kvalitetskontrolprocesser med state-of-the-art udstyr.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d0c06b6 elementor-mobile-align-center elementor-align-center elementor-widget elementor-widget-button\" data-id=\"5d0c06b6\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/da\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kontakt os<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6021db4e e-flex e-con-boxed e-con e-parent\" data-id=\"6021db4e\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-474e3b4e elementor-widget elementor-widget-heading\" data-id=\"474e3b4e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Relateret information<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ba2452d elementor-posts__hover-none elementor-grid-2 elementor-grid-tablet-2 elementor-grid-mobile-1 elementor-posts--thumbnail-top elementor-widget elementor-widget-posts\" data-id=\"6ba2452d\" data-element_type=\"widget\" data-settings=\"{&quot;cards_row_gap&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:80,&quot;sizes&quot;:[]},&quot;cards_row_gap_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:71,&quot;sizes&quot;:[]},&quot;cards_row_gap_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:30,&quot;sizes&quot;:[]},&quot;cards_columns&quot;:&quot;2&quot;,&quot;cards_columns_tablet&quot;:&quot;2&quot;,&quot;cards_columns_mobile&quot;:&quot;1&quot;}\" data-widget_type=\"posts.cards\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-posts-container elementor-posts elementor-posts--skin-cards elementor-grid\">\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-2253 post type-post status-publish format-standard hentry category-vacuum-leak-test tag-astm-d3078 tag-astm-d4991 tag-vacuum-leak-tester\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h4 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/www.leakagetester.com\/da\/lt-02-leak-tester\/\" >\n\t\t\t\tLT-02 L\u00e6kagetester\t\t\t<\/a>\n\t\t<\/h4>\n\t\t\t\t<div class=\"elementor-post__excerpt\">\n\t\t\t<p> De <strong>LT-02 L\u00e6kagetester<\/strong> er en h\u00f8jtydende, automatisk vakuumtestl\u00f8sning, der er specielt designet til at detektere l\u00e6kager i fleksibel emballage, is\u00e6r i applikationer, hvor headspace-gas er til stede. Dette udstyr bruges almindeligvis i f\u00f8devare-, drikkevare-, farmaceutiske og andre industrier, hvor emballagep\u00e5lidelighed er afg\u00f8rende for at opretholde produktkvaliteten.<\/p>\n\t\t<\/div>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/www.leakagetester.com\/da\/lt-02-leak-tester\/\" aria-label=\"Read more about LT-02 Leak Tester\" tabindex=\"-1\" >\n\t\t\tL\u00e6s mere\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-2179 post type-post status-publish format-standard hentry category-vacuum-leak-test tag-astm-d3078 tag-astm-d4991 tag-vacuum-leak-tester\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h4 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/www.leakagetester.com\/da\/lt-03-leak-tester\/\" >\n\t\t\t\tLT-03 L\u00e6kagetester\t\t\t<\/a>\n\t\t<\/h4>\n\t\t\t\t<div class=\"elementor-post__excerpt\">\n\t\t\t<p>LT-03 L\u00e6kagetesteren er en avanceret enhed, der er udviklet til streng vurdering af emballageforseglingsintegritet p\u00e5 tv\u00e6rs af forskellige industrier. Dette udstyr er afg\u00f8rende for at verificere, at emballagen bevarer sine beskyttende egenskaber, og derved sikre produktkvalitet og sikkerhed. LT-03 er s\u00e6rligt velegnet til applikationer, der involverer fleksibel emballage, men kan ogs\u00e5 tilpasses til at teste ikke-fleksible og stive materialer gennem sit tilpassede design.<\/p>\n\t\t<\/div>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/www.leakagetester.com\/da\/lt-03-leak-tester\/\" aria-label=\"Read more about LT-03 Leak Tester\" tabindex=\"-1\" >\n\t\t\tL\u00e6s mere\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<\/div>\n\t\t\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 8871-5 Elastomeric parts for parenterals and for devices for pharmaceutical usePart 5:Functional requirements and testing Request a Quote Standard Summary Maintaining the sterility of parenteral drugs is a critical concern in the pharmaceutical and medical device industries. ISO 8871-5 provides a structured testing approach for assessing the functional integrity of elastomeric closures used with [&#8230;]","protected":false},"author":2,"featured_media":0,"parent":2112,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-4067","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ISO 8871-5 Vial Leak Test for Vial Rubber Closure Self-Sealing - Leakage Tester<\/title>\n<meta name=\"description\" content=\"Understand ISO 8871-5 for evaluating vial rubber closure self-sealing using the vial leak test procedure. Discover reliable testing methods with Cell Instruments\u2019 vial leak testing machines.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.leakagetester.com\/da\/standards\/iso-8871-5\/\" \/>\n<meta property=\"og:locale\" content=\"da_DK\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ISO 8871-5 Vial Leak Test for Vial Rubber Closure Self-Sealing Measurement\" \/>\n<meta property=\"og:description\" content=\"Understand ISO 8871-5 for evaluating vial rubber closure self-sealing using the vial leak test procedure. Discover reliable testing methods with Cell Instruments\u2019 vial leak testing machines.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.leakagetester.com\/da\/standards\/iso-8871-5\/\" \/>\n<meta property=\"og:site_name\" content=\"Leakage Tester\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/cellinstruments\/\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-22T06:46:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"ISO 8871-5 Vial Leak Test for Vial Rubber Closure Self-Sealing Measurement\" \/>\n<meta name=\"twitter:description\" content=\"Understand ISO 8871-5 for evaluating vial rubber closure self-sealing using the vial leak test procedure. Discover reliable testing methods with Cell Instruments\u2019 vial leak testing machines.\" \/>\n<meta name=\"twitter:label1\" content=\"Estimeret l\u00e6setid\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/\",\"url\":\"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/\",\"name\":\"ISO 8871-5 Vial Leak Test for Vial Rubber Closure Self-Sealing - Leakage Tester\",\"isPartOf\":{\"@id\":\"https:\/\/www.leakagetester.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp\",\"datePublished\":\"2025-04-22T05:58:51+00:00\",\"dateModified\":\"2025-04-22T06:46:01+00:00\",\"description\":\"Understand ISO 8871-5 for evaluating vial rubber closure self-sealing using the vial leak test procedure. Discover reliable testing methods with Cell Instruments\u2019 vial leak testing machines.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#breadcrumb\"},\"inLanguage\":\"da-DK\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"da-DK\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#primaryimage\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.leakagetester.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Standards\",\"item\":\"https:\/\/www.leakagetester.com\/standards\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ISO 8871-5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.leakagetester.com\/#website\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"name\":\"Leakage Testing Solutions\",\"description\":\"CELL INSTRUMENTS CO., LTD.\",\"publisher\":{\"@id\":\"https:\/\/www.leakagetester.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.leakagetester.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"da-DK\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.leakagetester.com\/#organization\",\"name\":\"Cell Instruments Co., Ltd.\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"da-DK\",\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"width\":1269,\"height\":342,\"caption\":\"Cell Instruments Co., Ltd.\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/cellinstruments\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ISO 8871-5 L\u00e6kagetest af h\u00e6tteglas med selvforseglende gummilukning - l\u00e6kagetester","description":"Forst\u00e5 ISO 8871-5 til evaluering af h\u00e6tteglasgummilukkers selvforsegling ved hj\u00e6lp af h\u00e6tteglasl\u00e6kagetestproceduren. Oplev p\u00e5lidelige testmetoder med Cell Instruments\u2019 maskiner til l\u00e6kagetest af h\u00e6tteglas.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.leakagetester.com\/da\/standards\/iso-8871-5\/","og_locale":"da_DK","og_type":"article","og_title":"ISO 8871-5 Vial Leak Test for Vial Rubber Closure Self-Sealing Measurement","og_description":"Understand ISO 8871-5 for evaluating vial rubber closure self-sealing using the vial leak test procedure. Discover reliable testing methods with Cell Instruments\u2019 vial leak testing machines.","og_url":"https:\/\/www.leakagetester.com\/da\/standards\/iso-8871-5\/","og_site_name":"Leakage Tester","article_publisher":"https:\/\/www.facebook.com\/cellinstruments\/","article_modified_time":"2025-04-22T06:46:01+00:00","og_image":[{"width":600,"height":200,"url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_title":"ISO 8871-5 Vial Leak Test for Vial Rubber Closure Self-Sealing Measurement","twitter_description":"Understand ISO 8871-5 for evaluating vial rubber closure self-sealing using the vial leak test procedure. Discover reliable testing methods with Cell Instruments\u2019 vial leak testing machines.","twitter_misc":{"Estimeret l\u00e6setid":"6 minutter"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/","url":"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/","name":"ISO 8871-5 L\u00e6kagetest af h\u00e6tteglas med selvforseglende gummilukning - l\u00e6kagetester","isPartOf":{"@id":"https:\/\/www.leakagetester.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#primaryimage"},"image":{"@id":"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#primaryimage"},"thumbnailUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp","datePublished":"2025-04-22T05:58:51+00:00","dateModified":"2025-04-22T06:46:01+00:00","description":"Forst\u00e5 ISO 8871-5 til evaluering af h\u00e6tteglasgummilukkers selvforsegling ved hj\u00e6lp af h\u00e6tteglasl\u00e6kagetestproceduren. Oplev p\u00e5lidelige testmetoder med Cell Instruments\u2019 maskiner til l\u00e6kagetest af h\u00e6tteglas.","breadcrumb":{"@id":"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#breadcrumb"},"inLanguage":"da-DK","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/"]}]},{"@type":"ImageObject","inLanguage":"da-DK","@id":"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#primaryimage","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.leakagetester.com\/"},{"@type":"ListItem","position":2,"name":"Standards","item":"https:\/\/www.leakagetester.com\/standards\/"},{"@type":"ListItem","position":3,"name":"ISO 8871-5"}]},{"@type":"WebSite","@id":"https:\/\/www.leakagetester.com\/#website","url":"https:\/\/www.leakagetester.com\/","name":"L\u00e6kagetestl\u00f8sninger","description":"CELL INSTRUMENTS CO., LTD.","publisher":{"@id":"https:\/\/www.leakagetester.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.leakagetester.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"da-DK"},{"@type":"Organization","@id":"https:\/\/www.leakagetester.com\/#organization","name":"Cell Instruments Co., Ltd.","url":"https:\/\/www.leakagetester.com\/","logo":{"@type":"ImageObject","inLanguage":"da-DK","@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","width":1269,"height":342,"caption":"Cell Instruments Co., Ltd."},"image":{"@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/cellinstruments\/"]}]}},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"leakagetester","author_link":"https:\/\/www.leakagetester.com\/da\/author\/leakagetester\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 8871-5 Elastomeric parts for parenterals and for devices for pharmaceutical usePart 5:Functional requirements and testing Request a Quote Standard Summary Maintaining the sterility of parenteral drugs is a critical concern in the pharmaceutical and medical device industries. ISO 8871-5 provides a structured testing approach for assessing the functional integrity of elastomeric closures used with&hellip;","_links":{"self":[{"href":"https:\/\/www.leakagetester.com\/da\/wp-json\/wp\/v2\/pages\/4067","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.leakagetester.com\/da\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.leakagetester.com\/da\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/da\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/da\/wp-json\/wp\/v2\/comments?post=4067"}],"version-history":[{"count":0,"href":"https:\/\/www.leakagetester.com\/da\/wp-json\/wp\/v2\/pages\/4067\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/da\/wp-json\/wp\/v2\/pages\/2112"}],"wp:attachment":[{"href":"https:\/\/www.leakagetester.com\/da\/wp-json\/wp\/v2\/media?parent=4067"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}