{"id":4445,"date":"2025-12-11T15:08:25","date_gmt":"2025-12-11T07:08:25","guid":{"rendered":"https:\/\/www.leakagetester.com\/?page_id=4445"},"modified":"2025-12-11T15:28:48","modified_gmt":"2025-12-11T07:28:48","slug":"astm-e493","status":"publish","type":"page","link":"https:\/\/www.leakagetester.com\/da\/standards\/astm-e493\/","title":{"rendered":"ASTM E493"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"4445\" class=\"elementor elementor-4445\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-40854497 e-con-full e-flex e-con e-parent\" data-id=\"40854497\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-7b6e2650 e-con-full e-flex e-con e-child\" data-id=\"7b6e2650\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1ed62b75 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"1ed62b75\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ASTM E493<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-649c5ca3 e-con-full e-flex e-con e-child\" data-id=\"649c5ca3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-528d414f elementor-widget elementor-widget-heading\" data-id=\"528d414f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h5 class=\"elementor-heading-title elementor-size-default\">Standardpraksis for l\u00e6kager ved brug af massespektrometer-l\u00e6kagedetektor i Inside-Out-testtilstand<\/h5>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4227f1f3 elementor-tablet-align-center elementor-mobile-align-center elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-button\" data-id=\"4227f1f3\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:200}\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/da\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Anmod om et tilbud<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7f37671f e-flex e-con-boxed e-con e-parent\" data-id=\"7f37671f\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-7479e6a9 e-con-full e-flex e-con e-child\" data-id=\"7479e6a9\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c1f01b8 elementor-widget elementor-widget-heading\" data-id=\"2c1f01b8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Standardoversigt<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a7ff4e2 elementor-widget elementor-widget-text-editor\" data-id=\"a7ff4e2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"424\" data-end=\"1049\">ASTM E493 definerer en struktureret praksis for evaluering af l\u00e6kage i forseglede komponenter ved hj\u00e6lp af en massespektrometer-l\u00e6kagedetektor i inside-out-tilstand. Industrier som mikroelektronik, medicinsk udstyr og pr\u00e6cisionsinstrumentering er afh\u00e6ngige af denne metode for at bekr\u00e6fte integriteten af hermetiske pakker. Ved at anvende principperne i ASTM E493 f\u00e5r ingeni\u00f8rer mulighed for at identificere fine l\u00e6kager, beregne faktiske l\u00e6kagehastigheder og opretholde produktp\u00e5lidelighed.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-58d7dfdf e-con-full e-flex e-con e-child\" data-id=\"58d7dfdf\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4aba77f5 elementor-widget elementor-widget-image\" data-id=\"4aba77f5\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.astm.org\/d3078-02r21e01.html\" target=\"_blank\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"200\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp\" class=\"attachment-medium size-medium wp-image-4448\" alt=\"ASTM E493\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp 600w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493-18x6.webp 18w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-38d9a2dc e-flex e-con-boxed e-con e-parent\" data-id=\"38d9a2dc\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-22b1040c e-con-full e-flex e-con e-child\" data-id=\"22b1040c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c1b4a01 elementor-widget elementor-widget-heading\" data-id=\"2c1b4a01\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Standard beskrivelse<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2dbe846b elementor-widget elementor-widget-text-editor\" data-id=\"2dbe846b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1686\" data-end=\"2154\">ASTM E493 omhandler enheder, der er forseglet f\u00f8r testning, herunder halvledere, rel\u00e6er, pyrotekniske komponenter og sensorer med h\u00f8j p\u00e5lidelighed. Standarden kr\u00e6ver, at testartiklen indeholder helium ved et kendt eller beregneligt indre tryk under m\u00e5lingen. Hvis delen ikke kan fyldes f\u00f8r forsegling, introducerer metoden helium gennem en kontrolleret bombeproces. Denne tilgang sikrer, at selv den mindste vej gennem enhedens v\u00e6g kan detekteres.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-346b4bef e-con-full e-flex e-con e-child\" data-id=\"346b4bef\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8704851 elementor-widget elementor-widget-text-editor\" data-id=\"8704851\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2156\" data-end=\"2336\">Praksis beskriver to prim\u00e6re teknikker:<\/p><ul><li data-start=\"2156\" data-end=\"2336\"><strong data-start=\"2204\" data-end=\"2221\">Testmetode A<\/strong> bruger heliumbomber til at introducere sporingsgassen.<\/li><li data-start=\"2156\" data-end=\"2336\"><strong data-start=\"2273\" data-end=\"2290\">Testmetode B<\/strong> bruger forfyldning med helium f\u00f8r forsegling.<\/li><\/ul><p data-start=\"2338\" data-end=\"2533\">I begge tilf\u00e6lde kommer delen derefter ind i et evakueret kabinet, der er forbundet med en massespektrometer-l\u00e6kagedetektor. N\u00e5r der er en l\u00e6kage, m\u00e5ler detektoren heliumflowet og udsender en angivet hastighed.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3ae6b8a e-flex e-con-boxed e-con e-parent\" data-id=\"3ae6b8a\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-8f24e53 e-con-full e-flex e-con e-child\" data-id=\"8f24e53\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-6905cde e-con-full e-flex e-con e-child\" data-id=\"6905cde\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-61e733b elementor-widget elementor-widget-heading\" data-id=\"61e733b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testmetode A: Bombeprocedure<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5930041 elementor-widget elementor-widget-heading\" data-id=\"5930041\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">Forberedelse af testdel ved bombning<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a52d762 e-con-full e-flex e-con e-child\" data-id=\"a52d762\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6e9e0cd elementor-widget elementor-widget-text-editor\" data-id=\"6e9e0cd\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2578\" data-end=\"2923\">Bombning anvendes, n\u00e5r direkte intern gasp\u00e5fyldning ikke er mulig. De forseglede komponenter forbliver i et heliumtrykkammer i en forudbestemt periode. Bombetid, tryk og opholdstid har direkte indflydelse p\u00e5 f\u00f8lsomheden. Utilstr\u00e6kkelig kontrol kan f\u00f8re til inkonsekvente resultater, s\u00e5 bedste praksis indeb\u00e6rer standardisering af disse v\u00e6rdier p\u00e5 tv\u00e6rs af partier.<\/p><p data-start=\"2925\" data-end=\"3330\">Efter bombningen skal operat\u00f8rerne fjerne overfladehelium ved hj\u00e6lp af nitrogenskylning eller kontrolleret t\u00f8rring. Dette trin forhindrer sorberet helium i at producere baggrundssignaler p\u00e5 detektoren. N\u00e5r delene er rengjorte, placeres de i testkabinettet til m\u00e5ling. Ingeni\u00f8rer registrerer den angivne l\u00e6kagehastighed og den tid, der er g\u00e5et mellem bombning og testning, hvilket p\u00e5virker beregningen af den faktiske l\u00e6kagehastighed.<\/p><p data-start=\"3332\" data-end=\"3367\">Standarden indeholder en ligning:<\/p><p><img decoding=\"async\" class=\"size-full wp-image-4449 aligncenter\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493-Test-Method-A.webp\" alt=\"ASTM E493 Testmetode A\" width=\"302\" height=\"65\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493-Test-Method-A.webp 302w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493-Test-Method-A-18x4.webp 18w\" sizes=\"(max-width: 302px) 100vw, 302px\" \/><\/p><p data-start=\"3437\" data-end=\"3581\">Dette forhold sikrer, at den beregnede faktiske l\u00e6kagehastighed forbliver konservativ og indeholder en indbygget sikkerhedsfaktor for kritiske komponenter.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7b391d0 e-flex e-con-boxed e-con e-parent\" data-id=\"7b391d0\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-b327d60 e-con-full e-flex e-con e-child\" data-id=\"b327d60\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-91fcac1 elementor-widget elementor-widget-text-editor\" data-id=\"91fcac1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3631\" data-end=\"3932\">N\u00e5r enheden kan fyldes med helium f\u00f8r forseglingen, giver metode B en mere direkte arbejdsgang. Delen fyldes ved et kendt tryk, forsegles og testes under de samme inside-out-forhold som metode A. Da der ikke sker nogen bombning, fjerner beregningen den f\u00f8rste parentes i den foreg\u00e5ende ligning:<\/p>\n<p data-start=\"3631\" data-end=\"3932\"><img decoding=\"async\" class=\"size-full wp-image-4450 aligncenter\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E439-Method-B.webp\" alt=\"ASTM E439 Metode B\" width=\"150\" height=\"58\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E439-Method-B.webp 150w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E439-Method-B-18x7.webp 18w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/p>\n<p data-start=\"3974\" data-end=\"4085\">Fordi det interne tryk er kendt, underst\u00f8tter metode B ofte en strammere kvalitetskontrol og hurtigere cyklustider.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d9a5245 e-con-full e-flex e-con e-child\" data-id=\"d9a5245\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-6cf77b9 e-con-full e-flex e-con e-child\" data-id=\"6cf77b9\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-99feec5 elementor-widget elementor-widget-heading\" data-id=\"99feec5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testmetode B: Forfyldning med helium<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2a8993b elementor-widget elementor-widget-heading\" data-id=\"2a8993b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">est delforberedelse ved forudfyldning<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-897aaf5 e-flex e-con-boxed e-con e-parent\" data-id=\"897aaf5\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-23d08cc elementor-widget elementor-widget-heading\" data-id=\"23d08cc\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Betydning for kvalitet og p\u00e5lidelighed<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-48e4aa6 elementor-widget elementor-widget-text-editor\" data-id=\"48e4aa6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4138\" data-end=\"4459\">Producenter bruger ASTM E493 til at bekr\u00e6fte, at hermetisk forseglede enheder forhindrer langvarig indtr\u00e6ngen af luft, vanddamp og forurenende stoffer. Selv minimal l\u00e6kage kan nedbryde mikroelektronik eller f\u00f8lsomme medicinske komponenter over tid. Korrekt udf\u00f8relse af denne metode beskytter downstream-ydelsen og reducerer fejl i felten.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c6c9624 elementor-widget elementor-widget-heading\" data-id=\"c6c9624\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Forstyrrelser og god praksis<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-95095df elementor-widget elementor-widget-text-editor\" data-id=\"95095df\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4855\" data-end=\"5327\">Overfladebel\u00e6gninger, snavs, polymere materialer og ru teksturer kan fastholde helium under bombning. Uden afhj\u00e6lpning kan disse interferenskilder forh\u00f8je baggrundsm\u00e5lingerne og skjule \u00e6gte l\u00e6kager. Nitrogenvask eller kontrolleret opvarmning reducerer ofte dette problem. I tilf\u00e6lde af meget store l\u00e6kager eller ekstremt sm\u00e5 indre volumener kan heliumet slippe ud f\u00f8r testning, hvilket kr\u00e6ver bobletest eller alternative metoder til store l\u00e6kager umiddelbart efter fjernelse fra kammeret.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3a2b679a e-flex e-con-boxed e-con e-parent\" data-id=\"3a2b679a\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-38014124 elementor-widget elementor-widget-heading\" data-id=\"38014124\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Leder du efter p\u00e5lideligt udstyr til l\u00e6kages\u00f8gning?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-53b530f2 elementor-widget elementor-widget-text-editor\" data-id=\"53b530f2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0G\u00e5 ikke glip af chancen for at optimere dine kvalitetskontrolprocesser med state-of-the-art udstyr.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d0c06b6 elementor-mobile-align-center elementor-align-center elementor-widget elementor-widget-button\" data-id=\"5d0c06b6\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/da\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kontakt os<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ASTM E493 Standard Practice for Leaks Using the Mass Spectrometer Leak Detector in the Inside-Out Testing Mode Request a Quote Standard Summary ASTM E493 definerer en struktureret praksis for evaluering af l\u00e6kage i forseglede komponenter ved hj\u00e6lp af en massespektrometer-l\u00e6kagedetektor i inside-out-tilstand. Industrier som mikroelektronik, medicinsk udstyr og pr\u00e6cisionsinstrumentering er afh\u00e6ngige af [...].","protected":false},"author":2,"featured_media":0,"parent":2112,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-4445","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ASTM E493 - Helium &amp; Mass Spectrometer Leak Testing<\/title>\n<meta name=\"description\" content=\"ASTM E493 explains mass spectrometer inside-out leak testing for sealed devices. Learn methods, sensitivity, helium bombing, and how Cell Instruments supports precision leak testing.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.leakagetester.com\/da\/standards\/astm-e493\/\" \/>\n<meta property=\"og:locale\" content=\"da_DK\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ASTM E493 - Helium &amp; Mass Spectrometer Leak Testing\" \/>\n<meta property=\"og:description\" content=\"ASTM E493 explains mass spectrometer inside-out leak testing for sealed devices. Learn methods, sensitivity, helium bombing, and how Cell Instruments supports precision leak testing.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.leakagetester.com\/da\/standards\/astm-e493\/\" \/>\n<meta property=\"og:site_name\" content=\"Leakage Tester\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/cellinstruments\/\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-11T07:28:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"ASTM E493 - Helium &amp; Mass Spectrometer Leak Testing\" \/>\n<meta name=\"twitter:description\" content=\"ASTM E493 explains mass spectrometer inside-out leak testing for sealed devices. Learn methods, sensitivity, helium bombing, and how Cell Instruments supports precision leak testing.\" \/>\n<meta name=\"twitter:label1\" content=\"Estimeret l\u00e6setid\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/astm-e493\/\",\"url\":\"https:\/\/www.leakagetester.com\/standards\/astm-e493\/\",\"name\":\"ASTM E493 - Helium & Mass Spectrometer Leak Testing\",\"isPartOf\":{\"@id\":\"https:\/\/www.leakagetester.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp\",\"datePublished\":\"2025-12-11T07:08:25+00:00\",\"dateModified\":\"2025-12-11T07:28:48+00:00\",\"description\":\"ASTM E493 explains mass spectrometer inside-out leak testing for sealed devices. Learn methods, sensitivity, helium bombing, and how Cell Instruments supports precision leak testing.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#breadcrumb\"},\"inLanguage\":\"da-DK\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.leakagetester.com\/standards\/astm-e493\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"da-DK\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#primaryimage\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.leakagetester.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Standards\",\"item\":\"https:\/\/www.leakagetester.com\/standards\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ASTM E493\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.leakagetester.com\/#website\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"name\":\"Leakage Testing Solutions\",\"description\":\"CELL INSTRUMENTS CO., LTD.\",\"publisher\":{\"@id\":\"https:\/\/www.leakagetester.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.leakagetester.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"da-DK\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.leakagetester.com\/#organization\",\"name\":\"Cell Instruments Co., Ltd.\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"da-DK\",\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"width\":1269,\"height\":342,\"caption\":\"Cell Instruments Co., Ltd.\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/cellinstruments\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ASTM E493 - Helium- og massespektrometer-l\u00e6ktest","description":"ASTM E493 forklarer l\u00e6kagetest af massespektrometer indefra og ud for forseglede enheder. L\u00e6r om metoder, f\u00f8lsomhed, heliumbombning, og hvordan Cell Instruments underst\u00f8tter pr\u00e6cisionsl\u00e6kagetestning.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.leakagetester.com\/da\/standards\/astm-e493\/","og_locale":"da_DK","og_type":"article","og_title":"ASTM E493 - Helium & Mass Spectrometer Leak Testing","og_description":"ASTM E493 explains mass spectrometer inside-out leak testing for sealed devices. Learn methods, sensitivity, helium bombing, and how Cell Instruments supports precision leak testing.","og_url":"https:\/\/www.leakagetester.com\/da\/standards\/astm-e493\/","og_site_name":"Leakage Tester","article_publisher":"https:\/\/www.facebook.com\/cellinstruments\/","article_modified_time":"2025-12-11T07:28:48+00:00","og_image":[{"url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_title":"ASTM E493 - Helium & Mass Spectrometer Leak Testing","twitter_description":"ASTM E493 explains mass spectrometer inside-out leak testing for sealed devices. Learn methods, sensitivity, helium bombing, and how Cell Instruments supports precision leak testing.","twitter_misc":{"Estimeret l\u00e6setid":"4 minutter"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.leakagetester.com\/standards\/astm-e493\/","url":"https:\/\/www.leakagetester.com\/standards\/astm-e493\/","name":"ASTM E493 - Helium- og massespektrometer-l\u00e6ktest","isPartOf":{"@id":"https:\/\/www.leakagetester.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#primaryimage"},"image":{"@id":"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#primaryimage"},"thumbnailUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp","datePublished":"2025-12-11T07:08:25+00:00","dateModified":"2025-12-11T07:28:48+00:00","description":"ASTM E493 forklarer l\u00e6kagetest af massespektrometer indefra og ud for forseglede enheder. L\u00e6r om metoder, f\u00f8lsomhed, heliumbombning, og hvordan Cell Instruments underst\u00f8tter pr\u00e6cisionsl\u00e6kagetestning.","breadcrumb":{"@id":"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#breadcrumb"},"inLanguage":"da-DK","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.leakagetester.com\/standards\/astm-e493\/"]}]},{"@type":"ImageObject","inLanguage":"da-DK","@id":"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#primaryimage","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.leakagetester.com\/"},{"@type":"ListItem","position":2,"name":"Standards","item":"https:\/\/www.leakagetester.com\/standards\/"},{"@type":"ListItem","position":3,"name":"ASTM E493"}]},{"@type":"WebSite","@id":"https:\/\/www.leakagetester.com\/#website","url":"https:\/\/www.leakagetester.com\/","name":"L\u00e6kagetestl\u00f8sninger","description":"CELL INSTRUMENTS CO., LTD.","publisher":{"@id":"https:\/\/www.leakagetester.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.leakagetester.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"da-DK"},{"@type":"Organization","@id":"https:\/\/www.leakagetester.com\/#organization","name":"Cell Instruments Co., Ltd.","url":"https:\/\/www.leakagetester.com\/","logo":{"@type":"ImageObject","inLanguage":"da-DK","@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","width":1269,"height":342,"caption":"Cell Instruments Co., Ltd."},"image":{"@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/cellinstruments\/"]}]}},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"leakagetester","author_link":"https:\/\/www.leakagetester.com\/da\/author\/leakagetester\/"},"uagb_comment_info":0,"uagb_excerpt":"ASTM E493 Standard Practice for Leaks Using the Mass Spectrometer Leak Detector in the Inside-Out Testing Mode Request a Quote Standard Summary ASTM E493 defines a structured practice for evaluating leakage in sealed components using a mass spectrometer leak detector in the inside-out mode. Industries such as microelectronics, medical devices, and precision instrumentation rely on&hellip;","_links":{"self":[{"href":"https:\/\/www.leakagetester.com\/da\/wp-json\/wp\/v2\/pages\/4445","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.leakagetester.com\/da\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.leakagetester.com\/da\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/da\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/da\/wp-json\/wp\/v2\/comments?post=4445"}],"version-history":[{"count":0,"href":"https:\/\/www.leakagetester.com\/da\/wp-json\/wp\/v2\/pages\/4445\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/da\/wp-json\/wp\/v2\/pages\/2112"}],"wp:attachment":[{"href":"https:\/\/www.leakagetester.com\/da\/wp-json\/wp\/v2\/media?parent=4445"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}