{"id":4605,"date":"2026-04-28T13:36:06","date_gmt":"2026-04-28T05:36:06","guid":{"rendered":"https:\/\/www.leakagetester.com\/?page_id=4605"},"modified":"2026-04-28T13:37:42","modified_gmt":"2026-04-28T05:37:42","slug":"usp-381","status":"publish","type":"page","link":"https:\/\/www.leakagetester.com\/de\/standards\/usp-381\/","title":{"rendered":"USP 381"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"4605\" class=\"elementor elementor-4605\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-40854497 e-con-full e-flex e-con e-parent\" data-id=\"40854497\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-7b6e2650 e-con-full e-flex e-con e-child\" data-id=\"7b6e2650\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1ed62b75 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"1ed62b75\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">USP 381<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-649c5ca3 e-con-full e-flex e-con e-child\" data-id=\"649c5ca3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-528d414f elementor-widget elementor-widget-heading\" data-id=\"528d414f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h5 class=\"elementor-heading-title elementor-size-default\"> Elastomer-Verschluss f\u00fcr Injektionen<br>Test der Selbstdichtungskapazit\u00e4t<\/h5>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4227f1f3 elementor-tablet-align-center elementor-mobile-align-center elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-button\" data-id=\"4227f1f3\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:200}\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/de\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Angebot anfordern<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7f37671f e-flex e-con-boxed e-con e-parent\" data-id=\"7f37671f\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-7479e6a9 e-con-full e-flex e-con e-child\" data-id=\"7479e6a9\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c1f01b8 elementor-widget elementor-widget-heading\" data-id=\"2c1f01b8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Standardzusammenfassung<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7de8c97 elementor-widget elementor-widget-text-editor\" data-id=\"7de8c97\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"440\" data-end=\"718\"><strong data-start=\"440\" data-end=\"451\">USP 381<\/strong> definiert die kritischen Leistungsanforderungen f\u00fcr Elastomerverschl\u00fcsse, die in injizierbaren pharmazeutischen Verpackungen verwendet werden. Diese Verschl\u00fcsse - in der Regel Fl\u00e4schchenverschl\u00fcsse - m\u00fcssen folgende Eigenschaften aufweisen <strong data-start=\"620\" data-end=\"657\">Integrit\u00e4t des Beh\u00e4lterverschlusses (CCI)<\/strong> w\u00e4hrend der Lagerung, des Transports und der wiederholten Einstiche.<\/p>\n<p data-start=\"720\" data-end=\"973\">Der Schwerpunkt der Norm liegt auf <strong data-start=\"744\" data-end=\"770\">Funktionssicherheit<\/strong>, Dadurch wird sichergestellt, dass die Verschl\u00fcsse Kontamination und Auslaufen verhindern und gleichzeitig die Wiederverschlie\u00dfbarkeit erhalten bleibt. F\u00fcr Qualit\u00e4tskontrollteams dient die USP 381 als Ma\u00dfstab f\u00fcr die Validierung von Verschlusssystemen unter realen Bedingungen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-58d7dfdf e-con-full e-flex e-con e-child\" data-id=\"58d7dfdf\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4aba77f5 elementor-widget elementor-widget-image\" data-id=\"4aba77f5\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.astm.org\/d3078-02r21e01.html\" target=\"_blank\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"100\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2026\/04\/USP-381.webp\" class=\"attachment-medium size-medium wp-image-4608\" alt=\"USP 381\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2026\/04\/USP-381.webp 300w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2026\/04\/USP-381-18x6.webp 18w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a7ff4e2 elementor-widget elementor-widget-text-editor\" data-id=\"a7ff4e2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"6004\" data-end=\"6554\">USP 381 definiert Leistungsanforderungen f\u00fcr Elastomerverschl\u00fcsse, die in Verpackungen f\u00fcr injizierbare Arzneimittel verwendet werden, wobei der Schwerpunkt auf Integrit\u00e4t, Wiederverschlie\u00dfbarkeit und Auslaufsicherheit liegt. Zu den wichtigsten Tests geh\u00f6ren die Selbstabdichtung nach mehreren Durchstichen und das Eindringen von Methylenblau unter Vakuumbedingungen. Diese Pr\u00fcfungen stellen sicher, dass die Verschl\u00fcsse eine Kontamination verhindern und die Sterilit\u00e4t w\u00e4hrend des gesamten Produktlebenszyklus aufrechterhalten. Zuverl\u00e4ssige Pr\u00fcfmethoden, wie die vakuumbasierte Leckerkennung, verbessern die Genauigkeit und die Einhaltung der Vorschriften und unterst\u00fctzen die pharmazeutische Qualit\u00e4tssicherung und die beh\u00f6rdliche Zulassung.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-38d9a2dc e-flex e-con-boxed e-con e-parent\" data-id=\"38d9a2dc\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-22b1040c e-con-full e-flex e-con e-child\" data-id=\"22b1040c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c1b4a01 elementor-widget elementor-widget-heading\" data-id=\"2c1b4a01\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Funktionspr\u00fcfung von Elastomer-Verschl\u00fcssen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2dbe846b elementor-widget elementor-widget-text-editor\" data-id=\"2dbe846b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1024\" data-end=\"1211\">Der <strong data-start=\"1028\" data-end=\"1071\">Funktionspr\u00fcfung von Elastomerverschl\u00fcssen<\/strong> bewertet, ob Verschl\u00fcsse einer wiederholten Verwendung standhalten k\u00f6nnen, ohne die Sterilit\u00e4t zu beeintr\u00e4chtigen. Es umfasst mehrere \u00dcberpr\u00fcfungsans\u00e4tze wie z. B.:<\/p>\n<ul data-start=\"1213\" data-end=\"1342\">\n<li data-section-id=\"tiqte5\" data-start=\"1213\" data-end=\"1246\">Widerstandsf\u00e4higkeit gegen Nadeleinstiche<\/li>\n<li data-section-id=\"snooyk\" data-start=\"1247\" data-end=\"1286\">F\u00e4higkeit zur Wiederversiegelung nach dem Eindringen<\/li>\n<li data-section-id=\"1q1oeiv\" data-start=\"1287\" data-end=\"1342\">Dichtes Verhalten bei Druckunterschieden<\/li>\n<\/ul>\n<p data-start=\"1344\" data-end=\"1534\">Diese Tests simulieren den klinischen Gebrauch, bei dem die Fl\u00e4schchen mehrfach entnommen werden. Ein nachgiebiger Verschluss gew\u00e4hrleistet <strong data-start=\"1450\" data-end=\"1502\">kein Eindringen von Schadstoffen oder Austreten von Inhalten<\/strong>, auch nach wiederholten Einstichen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3ae6b8a e-flex e-con-boxed e-con e-parent\" data-id=\"3ae6b8a\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-6905cde e-con-full e-flex e-con e-child\" data-id=\"6905cde\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-61e733b elementor-widget elementor-widget-heading\" data-id=\"61e733b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test der Selbstdichtigkeit des Fl\u00e4schchenstopfens<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8704851 elementor-widget elementor-widget-text-editor\" data-id=\"8704851\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1576\" data-end=\"1725\">Der <strong data-start=\"1580\" data-end=\"1614\">Pr\u00fcfung der Selbstdichtigkeit des Fl\u00e4schchenstopfens<\/strong> ist ein zentraler Bestandteil der USP 381. Sie misst direkt die F\u00e4higkeit des Verschlusses, sich nach mehreren Durchstichen wieder zu verschlie\u00dfen.<\/p>\n<h3 data-section-id=\"k0lh0e\" data-start=\"1727\" data-end=\"1754\">\u00dcbersicht \u00fcber das Testverfahren<\/h3>\n<ul data-start=\"1755\" data-end=\"2089\">\n<li data-section-id=\"gicv2d\" data-start=\"1755\" data-end=\"1801\">10 K\u00fcvetten bis zum Nennvolumen mit Wasser f\u00fcllen<\/li>\n<li data-section-id=\"atyex9\" data-start=\"1802\" data-end=\"1839\">Verschl\u00fcsse anbringen und mit Kappen versiegeln<\/li>\n<li data-section-id=\"eg20aj\" data-start=\"1840\" data-end=\"1934\">Jeden Verschluss durchstechen <strong data-start=\"1862\" data-end=\"1904\">10 Mal mit einer neuen Injektionsnadel<\/strong>, unterschiedliche Einstichstellen<\/li>\n<li data-section-id=\"1tlazes\" data-start=\"1935\" data-end=\"1988\">Fl\u00e4schchen eintauchen in <strong data-start=\"1954\" data-end=\"1986\">0,1% Methylenblau-L\u00f6sung<\/strong><\/li>\n<li data-section-id=\"1htyiwy\" data-start=\"1989\" data-end=\"2030\">Anlegen eines Vakuums (~27 kPa) f\u00fcr 10 Minuten<\/li>\n<li data-section-id=\"c9yk9j\" data-start=\"2031\" data-end=\"2089\">Den Druck wiederherstellen und das Eintauchen f\u00fcr 30 Minuten beibehalten<\/li>\n<\/ul>\n<h3 data-section-id=\"1r9v1uk\" data-start=\"2091\" data-end=\"2114\">Kriterien f\u00fcr die Akzeptanz<\/h3>\n<blockquote data-start=\"2115\" data-end=\"2157\">\n<p data-start=\"2117\" data-end=\"2157\"><strong data-start=\"2117\" data-end=\"2157\">Keine Spur von blauem Farbstoff in einem Fl\u00e4schchen<\/strong><\/p>\n<\/blockquote>\n<p data-start=\"2159\" data-end=\"2249\">Diese Anforderung best\u00e4tigt, dass die Verschl\u00fcsse auch nach wiederholten Durchstichen intakt bleiben.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fed1035 e-flex e-con-boxed e-con e-parent\" data-id=\"fed1035\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-3384222 e-con-full e-flex e-con e-child\" data-id=\"3384222\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-705671e elementor-widget elementor-widget-heading\" data-id=\"705671e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Integrit\u00e4tstest f\u00fcr Elastomer-Verschl\u00fcsse<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d765a06 elementor-widget elementor-widget-text-editor\" data-id=\"d765a06\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2824\" data-end=\"2960\">Der <strong data-start=\"2828\" data-end=\"2867\">Integrit\u00e4tstest f\u00fcr Elastomerverschl\u00fcsse<\/strong> pr\u00fcft, ob das Verschlusssystem unter Stressbedingungen Leckagen und Verunreinigungen verhindert.<\/p>\n<p data-start=\"2962\" data-end=\"3006\">Zu den g\u00e4ngigen Methoden der Integrit\u00e4tsbewertung geh\u00f6ren:<\/p>\n<ul data-start=\"3007\" data-end=\"3059\">\n<li data-section-id=\"jhzx6z\" data-start=\"3007\" data-end=\"3023\">Vakuumzerfall<\/li>\n<li data-section-id=\"1dkpu5j\" data-start=\"3024\" data-end=\"3039\">Eindringen von Farbstoff<\/li>\n<li data-section-id=\"s7pmyn\" data-start=\"3040\" data-end=\"3059\">Blasenbildung<\/li>\n<\/ul>\n<p data-start=\"3061\" data-end=\"3197\">Die visuellen vakuumbasierten Methoden bieten unter anderem <strong data-start=\"3110\" data-end=\"3149\">direkte und intuitive Lecksuche<\/strong>, wodurch sie in den QC-Labors weit verbreitet sind.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fd99181 e-con-full e-flex e-con e-child\" data-id=\"fd99181\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7de0ebd elementor-widget elementor-widget-heading\" data-id=\"7de0ebd\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Fl\u00e4schchen Elastomer-Verschl\u00fcsse Dichtigkeit<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-49e4be9 elementor-widget elementor-widget-text-editor\" data-id=\"49e4be9\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2300\" data-end=\"2441\">Der <strong data-start=\"2304\" data-end=\"2347\">Elastomerverschl\u00fcsse f\u00fcr Fl\u00e4schchen Dichtigkeit<\/strong> spiegelt die F\u00e4higkeit des Verschlusses wider, unter mechanischer und druckbedingter Belastung eine dichte Abdichtung aufrechtzuerhalten.<\/p>\n<p data-start=\"2443\" data-end=\"2468\">Die St\u00e4rke der Dichtung ist abh\u00e4ngig von:<\/p>\n<ul data-start=\"2469\" data-end=\"2578\">\n<li data-section-id=\"2ej4cq\" data-start=\"2469\" data-end=\"2509\">Elastomerformulierung und Elastizit\u00e4t<\/li>\n<li data-section-id=\"stp8qh\" data-start=\"2510\" data-end=\"2557\">Kompression zwischen Stopfen und Fl\u00e4schchenabschluss<\/li>\n<li data-section-id=\"kjdc80\" data-start=\"2558\" data-end=\"2578\">Qualit\u00e4t der Verpressung<\/li>\n<\/ul>\n<p data-start=\"2580\" data-end=\"2777\">Eine robuste Dichtung gew\u00e4hrleistet <strong data-start=\"2602\" data-end=\"2646\">Langzeitstabilit\u00e4t und Transportsicherheit<\/strong>, insbesondere bei empfindlichen injizierbaren Arzneimitteln. Eine unzureichende Versiegelung kann zu Mikrolecks f\u00fchren, die das Niveau der Sterilit\u00e4tssicherung (SAL) beeintr\u00e4chtigen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-54762f0 e-flex e-con-boxed e-con e-parent\" data-id=\"54762f0\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-170208e e-con-full e-flex e-con e-child\" data-id=\"170208e\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-7812630 e-con-full e-flex e-con e-child\" data-id=\"7812630\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0cd2f44 elementor-widget elementor-widget-heading\" data-id=\"0cd2f44\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Integrit\u00e4t des Verschlusses nach Nadeleinstich<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-53d0c6d elementor-widget elementor-widget-text-editor\" data-id=\"53d0c6d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3248\" data-end=\"3415\"><strong data-start=\"3248\" data-end=\"3291\">Unversehrtheit des Verschlusses nach Nadeleinstich<\/strong> ist eine entscheidende Anforderung der USP 381. Jede Punktion stellt einen potenziellen Leckagepfad dar. Daher m\u00fcssen die Verschl\u00fcsse Folgendes aufweisen:<\/p>\n<ul data-start=\"3417\" data-end=\"3528\">\n<li data-section-id=\"114z2j3\" data-start=\"3417\" data-end=\"3455\">Elastische Erholung nach der Penetration<\/li>\n<li data-section-id=\"1pvmj81\" data-start=\"3456\" data-end=\"3491\">Widerstandsf\u00e4higkeit gegen Einrei\u00dfen oder Entkernen<\/li>\n<li data-section-id=\"q588ho\" data-start=\"3492\" data-end=\"3528\">Konsistente Wiederversiegelungsleistung<\/li>\n<\/ul>\n<p data-start=\"3530\" data-end=\"3679\">Wiederholte Punktionstests simulieren klinische Szenarien wie die Verwendung von Mehrfachdosis-Fl\u00e4schchen. Ein Fehlschlag in dieser Phase deutet auf ein hohes Kontaminationsrisiko hin.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4cbe13a elementor-widget elementor-widget-heading\" data-id=\"4cbe13a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Methylenblau-Lecktest<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60e9ebd elementor-widget elementor-widget-text-editor\" data-id=\"60e9ebd\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3715\" data-end=\"3824\">Der <strong data-start=\"3719\" data-end=\"3747\">Methylenblau-Lecktest<\/strong> ist eine weithin anerkannte Methode zur Erkennung von Leckagen in Fl\u00e4schchenverschlusssystemen.<\/p>\n<h3 data-section-id=\"1p9gofk\" data-start=\"3826\" data-end=\"3839\">Grundsatz<\/h3>\n<p data-start=\"3840\" data-end=\"3996\">Ein Druckunterschied dr\u00fcckt die Farbstoffl\u00f6sung in eventuell vorhandene Leckstellen. Wenn der Verschluss versagt, dringt der Farbstoff in das Fl\u00e4schchen ein und wird visuell nachweisbar.<\/p>\n<h3 data-section-id=\"1l3n95q\" data-start=\"3998\" data-end=\"4012\">Vorteile<\/h3>\n<ul data-start=\"4013\" data-end=\"4124\">\n<li data-section-id=\"1jgfk3b\" data-start=\"4013\" data-end=\"4048\">Hohe Empfindlichkeit gegen\u00fcber Mikrolecks<\/li>\n<li data-section-id=\"nxbsm0\" data-start=\"4049\" data-end=\"4081\">Einfache visuelle Interpretation<\/li>\n<li data-section-id=\"1p1j563\" data-start=\"4082\" data-end=\"4124\">Kosteng\u00fcnstig und weitgehend standardisiert<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-de8bc87 elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"de8bc87\" data-element_type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><a href=\"https:\/\/www.leakagetester.com\/de\/lt-03-leak-tester\/\" tabindex=\"-1\"><img fetchpriority=\"high\" decoding=\"async\" width=\"568\" height=\"694\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/LT-02-Leak-Tester-for-ASTM-D4991.webp\" class=\"attachment-full size-full wp-image-3720\" alt=\"LT-02 Dichtheitspr\u00fcfger\u00e4t f\u00fcr ASTM D4991\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/LT-02-Leak-Tester-for-ASTM-D4991.webp 568w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/LT-02-Leak-Tester-for-ASTM-D4991-327x400.webp 327w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/LT-02-Leak-Tester-for-ASTM-D4991-10x12.webp 10w\" sizes=\"(max-width: 568px) 100vw, 568px\" \/><\/a><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\"><a href=\"https:\/\/www.leakagetester.com\/de\/lt-03-leak-tester\/\">Praktische Umsetzung mit LT-03<\/a><\/h3><p class=\"elementor-image-box-description\">Der <b>Cell Instruments LT-03 Dichtheitspr\u00fcfger\u00e4t<\/b> verbessert die Methylenblau-Dichtheitspr\u00fcfung durch kontrollierte Vakuumbedingungen und klare Visualisierung.<br><h4>Die wichtigsten Vorteile sind:<\/h4>\n- Stabile Vakuumerzeugung bis zu -90 kPa<br>\n- Transparente Kammer f\u00fcr <b>Blasenbeobachtung in Echtzeit<\/b><br>\n- PLC-gesteuertes System f\u00fcr wiederholbare Pr\u00fcfungen<br>\n- Anpassbare Kammergr\u00f6\u00dfen f\u00fcr verschiedene Fl\u00e4schchenformate<br>\nIm Gegensatz zu manuellen Einstellungen gew\u00e4hrleistet der LT-03<b> einheitliche Testbedingungen<\/b>, Dadurch werden die Wiederholbarkeit und die \u00dcbereinstimmung mit USP 381 verbessert.<\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-df11fd3 e-flex e-con-boxed e-con e-parent\" data-id=\"df11fd3\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f88a6af elementor-widget elementor-widget-heading\" data-id=\"f88a6af\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Warum die Pr\u00fcfung nach USP 381 f\u00fcr die Qualit\u00e4tssicherung wichtig ist<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef8d4ef elementor-widget elementor-widget-text-editor\" data-id=\"ef8d4ef\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4735\" data-end=\"4785\">Die Pr\u00fcfung nach USP 381 gew\u00e4hrleistet, dass Elastomerverschl\u00fcsse:<\/p>\n<ul data-start=\"4786\" data-end=\"4911\">\n<li data-section-id=\"qlbuko\" data-start=\"4786\" data-end=\"4837\">Aufrechterhaltung der Sterilit\u00e4t w\u00e4hrend des gesamten Produktlebenszyklus<\/li>\n<li data-section-id=\"1kjrby4\" data-start=\"4838\" data-end=\"4873\">Widersteht wiederholter klinischer Anwendung<\/li>\n<li data-section-id=\"wytn3h\" data-start=\"4874\" data-end=\"4911\">Verunreinigung und Auslaufen verhindern<\/li>\n<\/ul>\n<p data-start=\"4913\" data-end=\"5032\">F\u00fcr pharmazeutische Hersteller und Verpackungslieferanten bedeutet die Einhaltung der Vorschriften <strong data-start=\"4989\" data-end=\"5031\">Vertrauen in die Regulierung und in den Markt<\/strong>.<\/p>\n<p data-start=\"5034\" data-end=\"5095\">Die Integration von standardisierten Ger\u00e4ten wie dem LT-03 erm\u00f6glicht:<\/p>\n<ul data-start=\"5096\" data-end=\"5198\">\n<li data-section-id=\"x1arb\" data-start=\"5096\" data-end=\"5127\">Verbesserte Testeffizienz<\/li>\n<li data-section-id=\"pexswy\" data-start=\"5128\" data-end=\"5160\">Geringere Variabilit\u00e4t der Bediener<\/li>\n<li data-section-id=\"1iblxk7\" data-start=\"5161\" data-end=\"5198\">Zuverl\u00e4ssige Dokumentation f\u00fcr Audits<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e54e744 e-flex e-con-boxed e-con e-parent\" data-id=\"e54e744\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2dbd503 elementor-widget elementor-widget-heading\" data-id=\"2dbd503\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQs<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-281f7fe elementor-widget elementor-widget-n-accordion\" data-id=\"281f7fe\" data-element_type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;multiple&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Akkordeon. \u00d6ffnen Sie Links mit Enter oder Space, schlie\u00dfen Sie sie mit Escape und navigieren Sie mit den Pfeiltasten.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4200\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4200\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 1. Was ist der Hauptzweck von USP 381? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4200\" class=\"elementor-element elementor-element-576265d e-con-full e-flex e-con e-child\" data-id=\"576265d\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-828db97 elementor-widget elementor-widget-text-editor\" data-id=\"828db97\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"5236\" data-end=\"5404\">USP 381 stellt sicher, dass Elastomerverschl\u00fcsse die Integrit\u00e4t, Wiederverschlie\u00dfbarkeit und Auslaufsicherheit von Verpackungen f\u00fcr Injektionsmittel gew\u00e4hrleisten.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4201\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4201\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 2. Wie viele Einstiche sind f\u00fcr den Selbstverschlusstest erforderlich? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4201\" class=\"elementor-element elementor-element-2aa4b9e e-con-full e-flex e-con e-child\" data-id=\"2aa4b9e\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2fbc638 elementor-widget elementor-widget-text-editor\" data-id=\"2fbc638\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"5406\" data-end=\"5557\">Jeder Verschluss muss standhalten <strong data-start=\"5501\" data-end=\"5540\">10 Einstiche an verschiedenen Stellen<\/strong> ohne Leckage.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4202\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4202\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 3. Warum wird Methylenblau bei der Dichtheitspr\u00fcfung verwendet? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4202\" class=\"elementor-element elementor-element-1f3dbb9 e-con-full e-flex e-con e-child\" data-id=\"1f3dbb9\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0c307be elementor-widget elementor-widget-text-editor\" data-id=\"0c307be\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"5559\" data-end=\"5683\">Durch den starken Farbkontrast sind selbst kleine Leckagen optisch erkennbar.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4203\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4203\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 4. Ist der Methylenblautest destruktiv? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4203\" class=\"elementor-element elementor-element-8728722 e-flex e-con-boxed e-con e-child\" data-id=\"8728722\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1e96c57 elementor-widget elementor-widget-text-editor\" data-id=\"1e96c57\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"5685\" data-end=\"5828\">Sie kann sein <strong data-start=\"5744\" data-end=\"5778\">nicht destruktiv oder destruktiv<\/strong>, je nach Testaufbau und Abnahmekriterien.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4204\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4204\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 5. Was sind die Ursachen f\u00fcr das Scheitern von Verschlussintegrit\u00e4tstests? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4204\" class=\"elementor-element elementor-element-52cee8b e-flex e-con-boxed e-con e-child\" data-id=\"52cee8b\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-09340ec elementor-widget elementor-widget-text-editor\" data-id=\"09340ec\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"5830\" data-end=\"5976\">H\u00e4ufige Ursachen sind mangelnde Elastizit\u00e4t des Elastomers, unsachgem\u00e4\u00dfe Verpressung und Materialfehler.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3a2b679a e-flex e-con-boxed e-con e-parent\" data-id=\"3a2b679a\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-38014124 elementor-widget elementor-widget-heading\" data-id=\"38014124\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Sie suchen zuverl\u00e4ssige Lecksuchger\u00e4te nach USP 381?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-53b530f2 elementor-widget elementor-widget-text-editor\" data-id=\"53b530f2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"6568\" data-end=\"7016\">Stellen Sie sicher, dass Ihre Fl\u00e4schchenverschl\u00fcsse die USP 381-Normen erf\u00fcllen - mit zuverl\u00e4ssigen und wiederholbaren Tests. Der LT-03 Leak Tester bietet eine pr\u00e4zise Vakuumkontrolle und eine klare visuelle Leckerkennung, wodurch die Methylenblau-Pr\u00fcfung effizienter und konformer wird. Optimieren Sie Ihren Arbeitsablauf in der Qualit\u00e4tskontrolle, reduzieren Sie die Variabilit\u00e4t und validieren Sie zuverl\u00e4ssig die Unversehrtheit der Verschl\u00fcsse nach der Nadelpunktion. Wenden Sie sich noch heute an Cell Instruments, um Ihre Pr\u00fcfm\u00f6glichkeiten f\u00fcr Elastomerverschl\u00fcsse zu verbessern.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d0c06b6 elementor-mobile-align-center elementor-align-center elementor-widget elementor-widget-button\" data-id=\"5d0c06b6\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/de\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kontaktieren Sie uns<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6021db4e e-flex e-con-boxed e-con e-parent\" data-id=\"6021db4e\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-474e3b4e elementor-widget elementor-widget-heading\" data-id=\"474e3b4e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Zugeh\u00f6rige Informationen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ba2452d elementor-posts__hover-none elementor-grid-2 elementor-grid-tablet-2 elementor-grid-mobile-1 elementor-posts--thumbnail-top elementor-widget elementor-widget-posts\" data-id=\"6ba2452d\" data-element_type=\"widget\" data-settings=\"{&quot;cards_row_gap&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:80,&quot;sizes&quot;:[]},&quot;cards_row_gap_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:71,&quot;sizes&quot;:[]},&quot;cards_row_gap_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:30,&quot;sizes&quot;:[]},&quot;cards_columns&quot;:&quot;2&quot;,&quot;cards_columns_tablet&quot;:&quot;2&quot;,&quot;cards_columns_mobile&quot;:&quot;1&quot;}\" data-widget_type=\"posts.cards\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-posts-container elementor-posts elementor-posts--skin-cards elementor-grid\">\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-2253 post type-post status-publish format-standard hentry category-vacuum-leak-test tag-astm-d3078 tag-astm-d4991 tag-vacuum-leak-tester\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h4 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/www.leakagetester.com\/de\/lt-02-leak-tester\/\" >\n\t\t\t\tLT-02 Dichtheitspr\u00fcfger\u00e4t\t\t\t<\/a>\n\t\t<\/h4>\n\t\t\t\t<div class=\"elementor-post__excerpt\">\n\t\t\t<p> Der <strong>LT-02 Dichtheitspr\u00fcfger\u00e4t<\/strong> ist eine leistungsstarke, automatische Vakuumtestl\u00f6sung, die speziell f\u00fcr die Erkennung von Lecks in flexiblen Verpackungen entwickelt wurde, insbesondere in Anwendungen, in denen Gas im Kopfraum vorhanden ist. Dieses Ger\u00e4t wird h\u00e4ufig in der Lebensmittel-, Getr\u00e4nke-, Pharma- und anderen Branchen eingesetzt, in denen die Zuverl\u00e4ssigkeit der Verpackung f\u00fcr die Aufrechterhaltung der Produktqualit\u00e4t von entscheidender Bedeutung ist.<\/p>\n\t\t<\/div>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/www.leakagetester.com\/de\/lt-02-leak-tester\/\" aria-label=\"Lesen Sie mehr \u00fcber LT-02 Lecktester\" tabindex=\"-1\" >\n\t\t\tMehr lesen\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-2179 post type-post status-publish format-standard hentry category-vacuum-leak-test tag-astm-d3078 tag-astm-d4991 tag-vacuum-leak-tester\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h4 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/www.leakagetester.com\/de\/lt-03-leak-tester\/\" >\n\t\t\t\tLT-03 Dichtheitspr\u00fcfger\u00e4t\t\t\t<\/a>\n\t\t<\/h4>\n\t\t\t\t<div class=\"elementor-post__excerpt\">\n\t\t\t<p>Der Dichtheitstester LT-03 ist ein hochmodernes Ger\u00e4t, das f\u00fcr die strenge Pr\u00fcfung der Integrit\u00e4t von Verpackungssiegeln in verschiedenen Branchen entwickelt wurde. Dieses Ger\u00e4t ist entscheidend, um zu \u00fcberpr\u00fcfen, ob die Verpackung ihre Schutzfunktionen beibeh\u00e4lt, und so die Produktqualit\u00e4t und -sicherheit zu gew\u00e4hrleisten. Der LT-03 eignet sich besonders f\u00fcr Anwendungen mit flexiblen Verpackungen, kann aber durch sein anpassbares Design auch zum Testen von nicht flexiblen und starren Materialien angepasst werden.<\/p>\n\t\t<\/div>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/www.leakagetester.com\/de\/lt-03-leak-tester\/\" aria-label=\"Lesen Sie mehr \u00fcber LT-03 Lecktester\" tabindex=\"-1\" >\n\t\t\tMehr lesen\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<\/div>\n\t\t\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>USP 381 Elastomerverschl\u00fcsse f\u00fcr InjektionenSelbstabdichtungstest Angebot anfordern Zusammenfassung der Norm USP 381 definiert die kritischen Leistungsanforderungen f\u00fcr Elastomerverschl\u00fcsse, die in injizierbaren pharmazeutischen Verpackungen verwendet werden. Diese Verschl\u00fcsse - in der Regel Fl\u00e4schchenverschl\u00fcsse - m\u00fcssen die Integrit\u00e4t des Beh\u00e4lterverschlusses (CCI) w\u00e4hrend der Lagerung, des Transports und wiederholter Nadelstiche aufrechterhalten. Der Schwerpunkt der Norm liegt auf der funktionalen Zuverl\u00e4ssigkeit, die sicherstellt, dass die Verschl\u00fcsse eine Kontamination verhindern und [...]","protected":false},"author":2,"featured_media":0,"parent":2112,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-4605","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>USP 381 | Self-Sealing Capacity Test for Elastomeric Closures<\/title>\n<meta name=\"description\" content=\"USP 381 defines performance requirements for elastomeric closures used in injectable packaging, focusing on integrity, resealability, and resistance to leakage\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.leakagetester.com\/de\/standards\/usp-381\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"USP 381 | Self-Sealing Capacity Test for Elastomeric Closures\" \/>\n<meta property=\"og:description\" content=\"USP 381 defines performance requirements for elastomeric closures used in injectable packaging, focusing on integrity, resealability, and resistance to leakage\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.leakagetester.com\/de\/standards\/usp-381\/\" \/>\n<meta property=\"og:site_name\" content=\"Leakage Tester\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/cellinstruments\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-28T05:37:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2026\/04\/USP-381.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t<meta property=\"og:image:height\" content=\"100\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"5\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/usp-381\/\",\"url\":\"https:\/\/www.leakagetester.com\/standards\/usp-381\/\",\"name\":\"USP 381 | Self-Sealing Capacity Test for Elastomeric Closures\",\"isPartOf\":{\"@id\":\"https:\/\/www.leakagetester.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/usp-381\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/usp-381\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2026\/04\/USP-381.webp\",\"datePublished\":\"2026-04-28T05:36:06+00:00\",\"dateModified\":\"2026-04-28T05:37:42+00:00\",\"description\":\"USP 381 defines performance requirements for elastomeric closures used in injectable packaging, focusing on integrity, resealability, and resistance to leakage\",\"breadcrumb\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/usp-381\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.leakagetester.com\/standards\/usp-381\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/usp-381\/#primaryimage\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2026\/04\/USP-381.webp\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2026\/04\/USP-381.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/usp-381\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.leakagetester.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Standards\",\"item\":\"https:\/\/www.leakagetester.com\/standards\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"USP 381\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.leakagetester.com\/#website\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"name\":\"Leakage Testing Solutions\",\"description\":\"CELL INSTRUMENTS CO., LTD.\",\"publisher\":{\"@id\":\"https:\/\/www.leakagetester.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.leakagetester.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.leakagetester.com\/#organization\",\"name\":\"Cell Instruments Co., Ltd.\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"width\":1269,\"height\":342,\"caption\":\"Cell Instruments Co., Ltd.\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/cellinstruments\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"USP 381 | Pr\u00fcfung der Selbstdichtungskapazit\u00e4t von Elastomerverschl\u00fcssen","description":"USP 381 definiert Leistungsanforderungen f\u00fcr Elastomerverschl\u00fcsse, die in Verpackungen f\u00fcr injizierbare Arzneimittel verwendet werden, wobei der Schwerpunkt auf der Integrit\u00e4t, der Wiederverschlie\u00dfbarkeit und dem Widerstand gegen Auslaufen liegt.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.leakagetester.com\/de\/standards\/usp-381\/","og_locale":"de_DE","og_type":"article","og_title":"USP 381 | Self-Sealing Capacity Test for Elastomeric Closures","og_description":"USP 381 defines performance requirements for elastomeric closures used in injectable packaging, focusing on integrity, resealability, and resistance to leakage","og_url":"https:\/\/www.leakagetester.com\/de\/standards\/usp-381\/","og_site_name":"Leakage Tester","article_publisher":"https:\/\/www.facebook.com\/cellinstruments\/","article_modified_time":"2026-04-28T05:37:42+00:00","og_image":[{"width":300,"height":100,"url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2026\/04\/USP-381.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"5\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.leakagetester.com\/standards\/usp-381\/","url":"https:\/\/www.leakagetester.com\/standards\/usp-381\/","name":"USP 381 | Pr\u00fcfung der Selbstdichtungskapazit\u00e4t von Elastomerverschl\u00fcssen","isPartOf":{"@id":"https:\/\/www.leakagetester.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.leakagetester.com\/standards\/usp-381\/#primaryimage"},"image":{"@id":"https:\/\/www.leakagetester.com\/standards\/usp-381\/#primaryimage"},"thumbnailUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2026\/04\/USP-381.webp","datePublished":"2026-04-28T05:36:06+00:00","dateModified":"2026-04-28T05:37:42+00:00","description":"USP 381 definiert Leistungsanforderungen f\u00fcr Elastomerverschl\u00fcsse, die in Verpackungen f\u00fcr injizierbare Arzneimittel verwendet werden, wobei der Schwerpunkt auf der Integrit\u00e4t, der Wiederverschlie\u00dfbarkeit und dem Widerstand gegen Auslaufen liegt.","breadcrumb":{"@id":"https:\/\/www.leakagetester.com\/standards\/usp-381\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.leakagetester.com\/standards\/usp-381\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.leakagetester.com\/standards\/usp-381\/#primaryimage","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2026\/04\/USP-381.webp","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2026\/04\/USP-381.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.leakagetester.com\/standards\/usp-381\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.leakagetester.com\/"},{"@type":"ListItem","position":2,"name":"Standards","item":"https:\/\/www.leakagetester.com\/standards\/"},{"@type":"ListItem","position":3,"name":"USP 381"}]},{"@type":"WebSite","@id":"https:\/\/www.leakagetester.com\/#website","url":"https:\/\/www.leakagetester.com\/","name":"L\u00f6sungen zur Dichtheitspr\u00fcfung","description":"CELL INSTRUMENTS CO., LTD.","publisher":{"@id":"https:\/\/www.leakagetester.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.leakagetester.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.leakagetester.com\/#organization","name":"Cell Instruments Co., Ltd.","url":"https:\/\/www.leakagetester.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","width":1269,"height":342,"caption":"Cell Instruments Co., Ltd."},"image":{"@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/cellinstruments\/"]}]}},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"leakagetester","author_link":"https:\/\/www.leakagetester.com\/de\/author\/leakagetester\/"},"uagb_comment_info":0,"uagb_excerpt":"USP 381 Elastomeric Closure for InjectionsSelf-Sealing Capacity Test Request a Quote Standard Summary USP 381 defines the critical performance requirements for elastomeric closures used in injectable pharmaceutical packaging. These closures\u2014commonly vial stoppers\u2014must maintain container closure integrity (CCI) throughout storage, transport, and repeated needle puncture. The standard focuses on functional reliability, ensuring closures prevent contamination and&hellip;","_links":{"self":[{"href":"https:\/\/www.leakagetester.com\/de\/wp-json\/wp\/v2\/pages\/4605","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.leakagetester.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.leakagetester.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/de\/wp-json\/wp\/v2\/comments?post=4605"}],"version-history":[{"count":5,"href":"https:\/\/www.leakagetester.com\/de\/wp-json\/wp\/v2\/pages\/4605\/revisions"}],"predecessor-version":[{"id":4618,"href":"https:\/\/www.leakagetester.com\/de\/wp-json\/wp\/v2\/pages\/4605\/revisions\/4618"}],"up":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/de\/wp-json\/wp\/v2\/pages\/2112"}],"wp:attachment":[{"href":"https:\/\/www.leakagetester.com\/de\/wp-json\/wp\/v2\/media?parent=4605"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}