{"id":4294,"date":"2025-07-11T14:31:00","date_gmt":"2025-07-11T06:31:00","guid":{"rendered":"https:\/\/www.leakagetester.com\/?p=4294"},"modified":"2025-07-17T17:12:37","modified_gmt":"2025-07-17T09:12:37","slug":"bubble-test-packaging","status":"publish","type":"post","link":"https:\/\/www.leakagetester.com\/eu\/bubble-test-packaging\/","title":{"rendered":"Burbuila-proba ontziratzea: malgu-paketeetan ihesak detektatzeko metodo fidagarria"},"content":{"rendered":"<h1 class=\"wp-block-heading\">Burbuila-proba ontziratzea - ASTM D3078<\/h1>\n\n\n\n<p><strong>Burbuila-probarako ontziratzea<\/strong> malgu ontzien ihes-erresistentzia ebaluatzeko zabalki onartutako teknika bat da, batez ere produktuaren osotasuna eta iraunkortasuna funtsezkoak diren industrietan. Janari-, farmazia-, mediku-gailu- eta kontsumo-ondasunetan ohikoa den metodo honek modu sinple baina eraginkorrean aukera ematen du ontzien akatsak begi-bistan antzemateko. Ontzien estandarrak gero eta zorrotzagoak direnez, ulertzea nola <strong>Ihesak probatzeko prozedura<\/strong> lanak\u2014batez ere definituta dauden moduan <strong><a href=\"https:\/\/www.leakagetester.com\/eu\/standards\/astm-d3078\/\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D3078<\/a><\/strong>\u2014kalitate ziurtapen taldeei beren ontzien baliozkotze prozesuak indartzen lagun dezake.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"LT-03 Cell Instruments huts-ihes-probagailua farmazeutiko botilak probatzeko\" width=\"1020\" height=\"574\" src=\"https:\/\/www.youtube.com\/embed\/z4wEZMIKR7Q?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Iragazpen-proba prozedura eta ASTM D3078 gida-jarraibideak<\/h2>\n\n\n\n<p>The <strong>Ihesak probatzeko prozedura<\/strong> atalean zehaztuta <a href=\"https:\/\/www.leakagetester.com\/eu\/standards\/astm-d3078\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>ASTM D3078<\/strong> <\/a>Ofizialki izenburua da <em>Ontzi malguetan ihesak burbuilen emisio bidez zehazteko proba-metodo estandarra<\/em>. Huts-ganbera bat eta likido-ingurune bat (ohikoena ura) erabiltzen ditu ihesak detektatzeko, burbuilen sorrera behatuz. Prozesuak proba-lagina ganberan murgiltzea, hutsa aplikatzea eta ihesak adierazten dituzten burbuila-korronteak zaintzea dakar.<\/p>\n\n\n\n<p>Gako urratsak <strong><a href=\"https:\/\/www.leakagetester.com\/eu\/standards\/astm-d3078\/\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D3078<\/a><\/strong> Ihes-probek honako hauek barne hartzen dituzte:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Urtarrez bete den hiru hereneko huts-ganbera garden batean pakete malgua murgiltzea.<\/li>\n\n\n\n<li>Paketea zabaltzen hasi arte hutsa aplikatzea.<\/li>\n\n\n\n<li>Hutsa denbora jakin batez mantentzea (adibidez, 30 segundotik 5 minutura).<\/li>\n\n\n\n<li>Zigiluen, izkinen edo zulaketaren bidezko burbuila-isurketa behatzea.<\/li>\n<\/ul>\n\n\n\n<p>Presentzia <strong>burbuila igorpena<\/strong> Istripuzko ihes baten existentzia baieztatzen du. Proba honek laguntzen du zehazten pakete-sistemak bere edukia airearen, hezetasunaren edo bakterioen sarreraren bezalako ingurumen-faktoreen aurka babestu dezakeen.<\/p>\n\n\n\n<p>Est\u00e1ndar hau maiz erabiltzen da ontziratzeko material berrietarako egokitasuna egiaztatzeko edo ontziratzeko zigilatze-prozesuak baliozkotzeko, arrisku handiko produktuekin, hala nola gailu mediko esterilekin edo hutsunean ontziratutako elikagaiekin.<\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-932ad273 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-3f5b6173\">\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/07\/LT-03\u6cc4\u9732\u6d4b\u8bd5\u4eea1.png\" alt=\"ASTM D3078 burbuila-probaren ontziratzea\" class=\"wp-image-4298\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/07\/LT-03\u6cc4\u9732\u6d4b\u8bd5\u4eea1.png 1024w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/07\/LT-03\u6cc4\u9732\u6d4b\u8bd5\u4eea1-400x400.png 400w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/07\/LT-03\u6cc4\u9732\u6d4b\u8bd5\u4eea1-800x800.png 800w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/07\/LT-03\u6cc4\u9732\u6d4b\u8bd5\u4eea1-280x280.png 280w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/07\/LT-03\u6cc4\u9732\u6d4b\u8bd5\u4eea1-768x768.png 768w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/07\/LT-03\u6cc4\u9732\u6d4b\u8bd5\u4eea1-12x12.png 12w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-d5151636\">\n<div class=\"wp-block-uagb-image uagb-block-4dc67cc5 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/07\/LT-03\u6cc4\u9732\u6d4b\u8bd5\u4eea2.png\" alt=\"\" width=\"1024\" height=\"1024\" title=\"\" role=\"img\" \/><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Zergatik erabili burbuila-testeko ontziratzea kalitate-kontrolan?<\/h2>\n\n\n\n<p><strong>Burbuila-probarako ontziratzea<\/strong> Sinpletasunagatik, kostu-eraginkortasunagatik eta ikusizko detekzio garbiagatik baloratzen da. Helio-ihesak detektatzeko edo huts-galera neurtzeko bezalako metodo teknikoagoekin alderatuta, burbuila-probak hainbat abantaila eskaintzen ditu eguneroko ekoizpen-inguruneetarako:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Azkar ikusizko baieztapena<\/strong> ihesaren presentziaren.<\/li>\n\n\n\n<li><strong>Lagin mota batzuetarako suntsiketarik gabekoa<\/strong>, huts-mailaren eta ontziratzeko materialaren arabera.<\/li>\n\n\n\n<li><strong>Ekipamendu-inbertsio txikia<\/strong> laborategientzat edo ekoizpen-lineetarako.<\/li>\n\n\n\n<li><strong>Sentsibilitate handia<\/strong> zulo txikietako ihesetara edo zigilatze akatsetara.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Ekipamenduaren ikuspegi orokorra: ihesak probatzeko profesionala den probagailu baten erabilera<\/h2>\n\n\n\n<p>Bitartean <strong>burbuila-probarako ontziratzea<\/strong> Metodoa oinarrizko ekipamendu erabiliz, espezializatutako bat erabiliz egin daiteke. <strong>Ihes-probatzailea<\/strong>\u2014hala nola unitate batetik <strong>Zelula-tresnak<\/strong>\u2014zehaztasuna, errepikagarritasuna eta segurtasuna hobetzen ditu. Ihesak probatzeko profesional batek normalean honako hauek ditu:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>A <strong>Gardena den huts-ganbera<\/strong> polikarbonato edo beira gogortu bezalako material iraunkorrez egina.<\/li>\n\n\n\n<li>A <strong>zehaztasun handiko huts-neurgailua<\/strong> Desiratutako presioa ezartzeko eta mantentzeko.<\/li>\n\n\n\n<li><strong>Sarrera- eta irteera-balbulak<\/strong> huts-erauzketa eta askapena kontrolatzeko.<\/li>\n\n\n\n<li>A <strong>plaka finkagailu gardena<\/strong> probak egiten diren bitartean laginaren flotazioa saihesteko eta posizio egonkorra bermatzeko ganberaren barruan.<\/li>\n\n\n\n<li><strong>Kontrol-interfaze digitala<\/strong> huts-maila eta denbora-tartea ezartzeko, operadorearen koherentzia hobetzeko.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Bubble Testingeko txostenak eta betetze-araudiak<\/h2>\n\n\n\n<p>Aran arabera <strong>ASTM D3078<\/strong>, ihes-proba txosten osatuak honako hauek barne hartu behar ditu:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Probak ASTM D3078 jarraitu zuela baieztatzea edo edozein aldaketaren xehetasunak.<\/li>\n\n\n\n<li>Materialaren eta laginaren identifikazioa.<\/li>\n\n\n\n<li>Huts-maila, fluido mota, proba iraupena eta laginaren hedapena behatu dira.<\/li>\n\n\n\n<li>Argi adierazpen bat <strong>ihesaren presentzia<\/strong>, kokapena ikusgai bada, kokapena barne.<\/li>\n\n\n\n<li>Probatutako lagin kopuru osoa eta hutsunen kopurua.<\/li>\n\n\n\n<li>Ontziratzeak onarpen-irizpideak bete dituen ala ez adierazten duen azken ebazpena.<\/li>\n<\/ul>\n\n\n\n<p>Xehetasun-maila honek bermatzen du proba-emaitzak erreproduzigarriak, jarraigarriak eta auditetan, kalitate-baliozkapenean edo oinarrizko kausa-ikerketaetan erabilgarriak izatea.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Ondorioa<\/h2>\n\n\n\n<p><strong>Burbuila-probarako ontziratzea<\/strong> Malgu ontziratzeko sistemetan ihesak detektatzeko zutabe nagusi izaten jarraitzen du. Ontziaren osotasuna egiaztatzeko modu sinple eta eraginkor bat eskaintzen du, mundu mailan onartutakoaren arabera gidatuta. <strong><a href=\"https:\/\/www.leakagetester.com\/eu\/standards\/astm-d3078\/\" target=\"_blank\" rel=\"noreferrer noopener\">ASTM D3078<\/a><\/strong> est\u00e1ndar. Hau ezarriz <strong>Ihesak probatzeko prozedura<\/strong> halako ekipamendu fidagarriak erabiliz <strong>Cell Instruments-en ihes-probagailua<\/strong>, enpresek produktuaren kalitatea hobetu, arauen betetzea ziurtatu eta marka-irudia babestu dezakete hainbat industrietan. Garapenean, baliozkotzean edo ekoizpen-lerroko lagin-hartzean erabili, burbuila-probak paketeen errendimenduari buruzko ekintzarako baliagarriak diren ezagutzak eskaintzen ditu.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Burbuila-proba ontziratzea \u2013 ASTM D3078  Burbuila-proba ontziratzea teknika zabal onartua da ontzi malguen ihes-erresistentzia ebaluatzeko, batez ere produktuaren osotasuna eta iraunkortasuna funtsezkoak diren industrietan. Elikagai-, farmazia-, mediku-gailu- eta kontsumo-ondasunetan ohikoa den metodo honek modu sinple baina eraginkorrean aukera ematen du ontzien akatsak begi-bistan antzemateko. [\u2026]","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-4294","post","type-post","status-publish","format-standard","hentry","category-test-method"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ASTM D3078 Bubble Leak Test Packaging Procedure Explained<\/title>\n<meta name=\"description\" content=\"\u200cMaster the ASTM D3078 Bubble Test for Flexible Packaging Seal Integrity with Cell Instruments&#039; Leak Testers\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.leakagetester.com\/eu\/bubble-test-packaging\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ASTM D3078 Bubble Leak Test Packaging Procedure Explained\" \/>\n<meta property=\"og:description\" content=\"\u200cMaster the ASTM D3078 Bubble Test for Flexible Packaging Seal Integrity with Cell Instruments&#039; Leak Testers\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.leakagetester.com\/eu\/bubble-test-packaging\/\" \/>\n<meta property=\"og:site_name\" content=\"Leakage Tester\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/cellinstruments\/\" \/>\n<meta property=\"article:published_time\" content=\"2025-07-11T06:31:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-17T09:12:37+00:00\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutua\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.leakagetester.com\/bubble-test-packaging\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.leakagetester.com\/bubble-test-packaging\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/person\/4723b9a20d5588ba757caeca19d25828\"},\"headline\":\"Bubble Test Packaging: Reliable Method for Leak Detection in Flexible Packs\",\"datePublished\":\"2025-07-11T06:31:00+00:00\",\"dateModified\":\"2025-07-17T09:12:37+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.leakagetester.com\/bubble-test-packaging\/\"},\"wordCount\":640,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.leakagetester.com\/#organization\"},\"articleSection\":[\"Test Method\"],\"inLanguage\":\"eu\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.leakagetester.com\/bubble-test-packaging\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.leakagetester.com\/bubble-test-packaging\/\",\"url\":\"https:\/\/www.leakagetester.com\/bubble-test-packaging\/\",\"name\":\"ASTM D3078 Bubble Leak Test Packaging Procedure Explained\",\"isPartOf\":{\"@id\":\"https:\/\/www.leakagetester.com\/#website\"},\"datePublished\":\"2025-07-11T06:31:00+00:00\",\"dateModified\":\"2025-07-17T09:12:37+00:00\",\"description\":\"\u200cMaster the ASTM D3078 Bubble Test for Flexible Packaging Seal Integrity with Cell Instruments' Leak Testers\",\"breadcrumb\":{\"@id\":\"https:\/\/www.leakagetester.com\/bubble-test-packaging\/#breadcrumb\"},\"inLanguage\":\"eu\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.leakagetester.com\/bubble-test-packaging\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.leakagetester.com\/bubble-test-packaging\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.leakagetester.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Bubble Test Packaging: Reliable Method for Leak Detection in Flexible Packs\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.leakagetester.com\/#website\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"name\":\"Leakage Testing Solutions\",\"description\":\"CELL INSTRUMENTS CO., LTD.\",\"publisher\":{\"@id\":\"https:\/\/www.leakagetester.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.leakagetester.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"eu\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.leakagetester.com\/#organization\",\"name\":\"Cell Instruments Co., Ltd.\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"eu\",\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"width\":1269,\"height\":342,\"caption\":\"Cell Instruments Co., Ltd.\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/cellinstruments\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/person\/4723b9a20d5588ba757caeca19d25828\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"eu\",\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/d3f8e85c3fec7fb8735942e6bc233d5c91b156505ef9cb87f4fd670fe1bb9008?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/d3f8e85c3fec7fb8735942e6bc233d5c91b156505ef9cb87f4fd670fe1bb9008?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"https:\/\/www.leakagetester.com\"],\"url\":\"https:\/\/www.leakagetester.com\/eu\/author\/admin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ASTM D3078 burbuila-ihes proba ontziratzeko prozedura azaldua","description":"Cell Instruments-eko ihes-probagailuekin ASTM D3078 burbuila-proba menderatu bilgarri malguen zigilu-osotasunerako","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.leakagetester.com\/eu\/bubble-test-packaging\/","og_locale":"en_US","og_type":"article","og_title":"ASTM D3078 Bubble Leak Test Packaging Procedure Explained","og_description":"\u200cMaster the ASTM D3078 Bubble Test for Flexible Packaging Seal Integrity with Cell Instruments' Leak Testers","og_url":"https:\/\/www.leakagetester.com\/eu\/bubble-test-packaging\/","og_site_name":"Leakage Tester","article_publisher":"https:\/\/www.facebook.com\/cellinstruments\/","article_published_time":"2025-07-11T06:31:00+00:00","article_modified_time":"2025-07-17T09:12:37+00:00","author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Est. reading time":"4 minutua"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.leakagetester.com\/bubble-test-packaging\/#article","isPartOf":{"@id":"https:\/\/www.leakagetester.com\/bubble-test-packaging\/"},"author":{"name":"admin","@id":"https:\/\/www.leakagetester.com\/#\/schema\/person\/4723b9a20d5588ba757caeca19d25828"},"headline":"Bubble Test Packaging: Reliable Method for Leak Detection in Flexible Packs","datePublished":"2025-07-11T06:31:00+00:00","dateModified":"2025-07-17T09:12:37+00:00","mainEntityOfPage":{"@id":"https:\/\/www.leakagetester.com\/bubble-test-packaging\/"},"wordCount":640,"commentCount":0,"publisher":{"@id":"https:\/\/www.leakagetester.com\/#organization"},"articleSection":["Test Method"],"inLanguage":"eu","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.leakagetester.com\/bubble-test-packaging\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.leakagetester.com\/bubble-test-packaging\/","url":"https:\/\/www.leakagetester.com\/bubble-test-packaging\/","name":"ASTM D3078 burbuila-ihes proba ontziratzeko prozedura azaldua","isPartOf":{"@id":"https:\/\/www.leakagetester.com\/#website"},"datePublished":"2025-07-11T06:31:00+00:00","dateModified":"2025-07-17T09:12:37+00:00","description":"Cell Instruments-eko ihes-probagailuekin ASTM D3078 burbuila-proba menderatu bilgarri malguen zigilu-osotasunerako","breadcrumb":{"@id":"https:\/\/www.leakagetester.com\/bubble-test-packaging\/#breadcrumb"},"inLanguage":"eu","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.leakagetester.com\/bubble-test-packaging\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.leakagetester.com\/bubble-test-packaging\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.leakagetester.com\/"},{"@type":"ListItem","position":2,"name":"Bubble Test Packaging: Reliable Method for Leak Detection in Flexible Packs"}]},{"@type":"WebSite","@id":"https:\/\/www.leakagetester.com\/#website","url":"https:\/\/www.leakagetester.com\/","name":"Ihesak probatzeko irtenbideak","description":"CELL INSTRUMENTS CO., LTD.","publisher":{"@id":"https:\/\/www.leakagetester.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.leakagetester.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"eu"},{"@type":"Organization","@id":"https:\/\/www.leakagetester.com\/#organization","name":"Cell Instruments Co., Ltd.","url":"https:\/\/www.leakagetester.com\/","logo":{"@type":"ImageObject","inLanguage":"eu","@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","width":1269,"height":342,"caption":"Cell Instruments Co., Ltd."},"image":{"@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/cellinstruments\/"]},{"@type":"Person","@id":"https:\/\/www.leakagetester.com\/#\/schema\/person\/4723b9a20d5588ba757caeca19d25828","name":"admin","image":{"@type":"ImageObject","inLanguage":"eu","@id":"https:\/\/www.leakagetester.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/d3f8e85c3fec7fb8735942e6bc233d5c91b156505ef9cb87f4fd670fe1bb9008?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d3f8e85c3fec7fb8735942e6bc233d5c91b156505ef9cb87f4fd670fe1bb9008?s=96&d=mm&r=g","caption":"admin"},"sameAs":["https:\/\/www.leakagetester.com"],"url":"https:\/\/www.leakagetester.com\/eu\/author\/admin\/"}]}},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"admin","author_link":"https:\/\/www.leakagetester.com\/eu\/author\/admin\/"},"uagb_comment_info":1,"uagb_excerpt":"Bubble Test Packaging- ASTM D3078 Bubble test packaging is a widely accepted technique for evaluating the leak resistance of flexible packaging, especially in industries where product integrity and shelf life are critical. Commonly used in food, pharmaceuticals, medical devices, and consumer goods, this method offers a simple yet effective way to visually detect packaging failures.&hellip;","_links":{"self":[{"href":"https:\/\/www.leakagetester.com\/eu\/wp-json\/wp\/v2\/posts\/4294","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.leakagetester.com\/eu\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.leakagetester.com\/eu\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/eu\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/eu\/wp-json\/wp\/v2\/comments?post=4294"}],"version-history":[{"count":0,"href":"https:\/\/www.leakagetester.com\/eu\/wp-json\/wp\/v2\/posts\/4294\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.leakagetester.com\/eu\/wp-json\/wp\/v2\/media?parent=4294"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.leakagetester.com\/eu\/wp-json\/wp\/v2\/categories?post=4294"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.leakagetester.com\/eu\/wp-json\/wp\/v2\/tags?post=4294"}],"curies":[{"name":"WordPress","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}