{"id":4067,"date":"2025-04-22T13:58:51","date_gmt":"2025-04-22T05:58:51","guid":{"rendered":"https:\/\/www.leakagetester.com\/?page_id=4067"},"modified":"2025-04-22T14:46:01","modified_gmt":"2025-04-22T06:46:01","slug":"iso-8871-5","status":"publish","type":"page","link":"https:\/\/www.leakagetester.com\/fr\/standards\/iso-8871-5\/","title":{"rendered":"ISO 8871-5"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"4067\" class=\"elementor elementor-4067\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-40854497 e-con-full e-flex e-con e-parent\" data-id=\"40854497\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-7b6e2650 e-con-full e-flex e-con e-child\" data-id=\"7b6e2650\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1ed62b75 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"1ed62b75\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 8871-5<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-649c5ca3 e-con-full e-flex e-con e-child\" data-id=\"649c5ca3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-528d414f elementor-widget elementor-widget-heading\" data-id=\"528d414f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h5 class=\"elementor-heading-title elementor-size-default\">Pi\u00e8ces en \u00e9lastom\u00e8re pour produits parent\u00e9raux et pour dispositifs \u00e0 usage pharmaceutique<br>Partie 5 : Exigences fonctionnelles et essais<\/h5>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4227f1f3 elementor-tablet-align-center elementor-mobile-align-center elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-button\" data-id=\"4227f1f3\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:200}\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/fr\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Demander un devis<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7f37671f e-flex e-con-boxed e-con e-parent\" data-id=\"7f37671f\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-7479e6a9 e-con-full e-flex e-con e-child\" data-id=\"7479e6a9\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c1f01b8 elementor-widget elementor-widget-heading\" data-id=\"2c1f01b8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">R\u00e9sum\u00e9 standard<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a7ff4e2 elementor-widget elementor-widget-text-editor\" data-id=\"a7ff4e2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le maintien de la st\u00e9rilit\u00e9 des m\u00e9dicaments administr\u00e9s par voie parent\u00e9rale est une pr\u00e9occupation essentielle des industries pharmaceutiques et des dispositifs m\u00e9dicaux. <strong data-start=\"519\" data-end=\"533\">ISO 8871-5<\/strong> fournit une approche de test structur\u00e9e pour \u00e9valuer l'int\u00e9grit\u00e9 fonctionnelle des fermetures en \u00e9lastom\u00e8re utilis\u00e9es avec les flacons d'injection. Plus pr\u00e9cis\u00e9ment, il d\u00e9crit les proc\u00e9dures permettant de d\u00e9terminer <strong data-start=\"713\" data-end=\"749\">flacon fermeture en caoutchouc auto-obturant<\/strong> et l'\u00e9tanch\u00e9it\u00e9 de l'interface entre la fermeture et la cuvette dans des conditions de stress simul\u00e9es.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-58d7dfdf e-con-full e-flex e-con e-child\" data-id=\"58d7dfdf\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4aba77f5 elementor-widget elementor-widget-image\" data-id=\"4aba77f5\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.astm.org\/d3078-02r21e01.html\" target=\"_blank\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"200\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp\" class=\"attachment-medium size-medium wp-image-4076\" alt=\"ISO 8871-5\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp 600w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5-18x6.webp 18w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-38d9a2dc e-flex e-con-boxed e-con e-parent\" data-id=\"38d9a2dc\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-22b1040c e-con-full e-flex e-con e-child\" data-id=\"22b1040c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c1b4a01 elementor-widget elementor-widget-heading\" data-id=\"2c1b4a01\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Description standard<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2dbe846b elementor-widget elementor-widget-text-editor\" data-id=\"2dbe846b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"1055\" data-end=\"1447\"><strong data-start=\"1055\" data-end=\"1069\">ISO 8871-5<\/strong>, intitul\u00e9 <em data-start=\"1078\" data-end=\"1200\">\u201cPi\u00e8ces en \u00e9lastom\u00e8re pour produits parent\u00e9raux et pour dispositifs \u00e0 usage pharmaceutique - Partie 5 : Exigences fonctionnelles et essais\u201d<\/em>, d\u00e9finit les exigences de performance et les m\u00e9thodes d'essai pour les bouchons en caoutchouc utilis\u00e9s dans les r\u00e9cipients m\u00e9dicaux st\u00e9riles. Ces fermetures sont souvent perc\u00e9es par des aiguilles hypodermiques et doivent pr\u00e9server l'int\u00e9grit\u00e9 du r\u00e9cipient en le refermant efficacement.<\/p><p class=\"\" data-start=\"1449\" data-end=\"1719\">\u00c9chec en <strong data-start=\"1460\" data-end=\"1478\">test d'\u00e9tanch\u00e9it\u00e9 des flacons<\/strong> peuvent compromettre la st\u00e9rilit\u00e9, entra\u00eenant un risque de contamination, de mauvais dosage ou de d\u00e9gradation de l'efficacit\u00e9. C'est pourquoi les fabricants et les professionnels du contr\u00f4le de la qualit\u00e9 suivent de pr\u00e8s cette norme pour assurer la conformit\u00e9 r\u00e9glementaire et la s\u00e9curit\u00e9 des patients.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-346b4bef e-con-full e-flex e-con e-child\" data-id=\"346b4bef\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7704d43d elementor-widget elementor-widget-image\" data-id=\"7704d43d\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1020\" height=\"578\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/Bottle-Vacuum-Leak-Test--1400x793.webp\" class=\"attachment-large size-large wp-image-3757\" alt=\"Test de fuite sous vide de la bouteille\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/Bottle-Vacuum-Leak-Test--1400x793.webp 1400w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/Bottle-Vacuum-Leak-Test--706x400.webp 706w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/Bottle-Vacuum-Leak-Test--768x435.webp 768w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/Bottle-Vacuum-Leak-Test--1536x870.webp 1536w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/Bottle-Vacuum-Leak-Test--18x10.webp 18w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/Bottle-Vacuum-Leak-Test-.webp 1617w\" sizes=\"(max-width: 1020px) 100vw, 1020px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9ee25e2 e-flex e-con-boxed e-con e-parent\" data-id=\"9ee25e2\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-9a921cd e-con-full e-flex e-con e-child\" data-id=\"9a921cd\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5f08225 elementor-widget elementor-widget-heading\" data-id=\"5f08225\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test d'\u00e9tanch\u00e9it\u00e9 des flacons, machine de test d'\u00e9tanch\u00e9it\u00e9 des flacons et proc\u00e9dure expliqu\u00e9e<br>Test d'\u00e9tanch\u00e9it\u00e9 et de p\u00e9n\u00e9tration de colorant pour les bouchons en caoutchouc des flacons<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9c9adad elementor-widget elementor-widget-text-editor\" data-id=\"9c9adad\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"1859\" data-end=\"2099\">La capacit\u00e9 d'auto-\u00e9tanch\u00e9it\u00e9 est l'une des propri\u00e9t\u00e9s les plus critiques \u00e9valu\u00e9es dans le cadre de la norme ISO 8871-5. Les <strong data-start=\"1950\" data-end=\"1986\">flacon fermeture en caoutchouc auto-obturant<\/strong> simule des piq\u00fbres d'aiguille r\u00e9p\u00e9t\u00e9es et \u00e9value si le bouchon se referme efficacement sous la pression du vide.<\/p><p class=\"\" data-start=\"2101\" data-end=\"2189\">En <strong>Annexes C et D de la norme ISO 8871-5<\/strong>, deux <strong data-start=\"2145\" data-end=\"2174\">proc\u00e9dures de test d'\u00e9tanch\u00e9it\u00e9 des flacons<\/strong> sont sp\u00e9cifi\u00e9s :<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6cb75bb e-n-tabs-mobile elementor-widget elementor-widget-n-tabs\" data-id=\"6cb75bb\" data-element_type=\"widget\" data-settings=\"{&quot;tabs_justify_horizontal&quot;:&quot;start&quot;,&quot;horizontal_scroll&quot;:&quot;disable&quot;}\" data-widget_type=\"nested-tabs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-tabs\" data-widget-number=\"113997243\" aria-label=\"Onglets. Ouvrez des \u00e9l\u00e9ments avec Entrer ou Espace, fermez-les avec Echape et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t<div class=\"e-n-tabs-heading\" role=\"tablist\">\n\t\t\t\t\t<button id=\"e-n-tab-title-1139972431\" class=\"e-n-tab-title\" aria-selected=\"true\" data-tab-index=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"e-n-tab-content-1139972431\" style=\"--n-tabs-title-order: 1;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tProc\u00e9dure d'essai d'auto-\u00e9tanch\u00e9it\u00e9 :\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t<button id=\"e-n-tab-title-1139972432\" class=\"e-n-tab-title\" aria-selected=\"false\" data-tab-index=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"e-n-tab-content-1139972432\" style=\"--n-tabs-title-order: 2;\">\n\t\t\t\t\t\t<span class=\"e-n-tab-title-text\">\n\t\t\t\tSolution de teinture Proc\u00e9dure d'\u00e9tanch\u00e9it\u00e9 (sans piercing) :\t\t\t<\/span>\n\t\t<\/button>\n\t\t\t\t\t<\/div>\n\t\t\t<div class=\"e-n-tabs-content\">\n\t\t\t\t<div id=\"e-n-tab-content-1139972431\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-1139972431\" data-tab-index=\"1\" style=\"--n-tabs-title-order: 1;\" class=\"e-active elementor-element elementor-element-4a09704 e-con-full e-flex e-con e-child\" data-id=\"4a09704\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5218dd8 elementor-widget elementor-widget-text-editor\" data-id=\"5218dd8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol data-start=\"2226\" data-end=\"2729\"><li class=\"\" data-start=\"2226\" data-end=\"2275\"><p class=\"\" data-start=\"2229\" data-end=\"2275\">Remplir chaque flacon propre avec de l'eau exempte de particules.<\/p><\/li><li class=\"\" data-start=\"2276\" data-end=\"2336\"><p class=\"\" data-start=\"2279\" data-end=\"2336\">Sceller le flacon \u00e0 l'aide de bouchons et de capsules \u00e0 sertir conform\u00e9ment \u00e0 la norme ISO 8362.<\/p><\/li><li class=\"\" data-start=\"2337\" data-end=\"2441\"><p class=\"\" data-start=\"2340\" data-end=\"2441\">\u00c0 l'aide d'aiguilles hypodermiques neuves, percer chaque bouchon en caoutchouc. <strong data-start=\"2399\" data-end=\"2411\">10 fois<\/strong>, en variant les positions \u00e0 chaque fois.<\/p><\/li><li class=\"\" data-start=\"2442\" data-end=\"2500\"><p class=\"\" data-start=\"2445\" data-end=\"2500\">Immerger les flacons dans <strong data-start=\"2466\" data-end=\"2499\">1 g\/L de solution de bleu de m\u00e9thyl\u00e8ne<\/strong>.<\/p><\/li><li class=\"\" data-start=\"2501\" data-end=\"2598\"><p class=\"\" data-start=\"2504\" data-end=\"2598\">Placer les flacons immerg\u00e9s dans un <strong data-start=\"2534\" data-end=\"2552\">chambre \u00e0 vide<\/strong> et r\u00e9duire la pression de 27 kPa pendant 10 minutes.<\/p><\/li><li class=\"\" data-start=\"2599\" data-end=\"2669\"><p class=\"\" data-start=\"2602\" data-end=\"2669\">R\u00e9tablir la pression atmosph\u00e9rique, maintenir l'immersion pendant encore 30 minutes.<\/p><\/li><li class=\"\" data-start=\"2670\" data-end=\"2729\"><p class=\"\" data-start=\"2673\" data-end=\"2729\">Rincer et v\u00e9rifier visuellement la pr\u00e9sence de colorant bleu \u00e0 l'int\u00e9rieur du flacon.<\/p><\/li><\/ol><p class=\"\" data-start=\"2731\" data-end=\"2824\">Ce test permet de d\u00e9terminer si le bouchon conserve sa capacit\u00e9 d'auto-obturation apr\u00e8s une utilisation r\u00e9p\u00e9t\u00e9e.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div id=\"e-n-tab-content-1139972432\" role=\"tabpanel\" aria-labelledby=\"e-n-tab-title-1139972432\" data-tab-index=\"2\" style=\"--n-tabs-title-order: 2;\" class=\"elementor-element elementor-element-1f65e67 e-con-full e-flex e-con e-child\" data-id=\"1f65e67\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8d828dd elementor-widget elementor-widget-text-editor\" data-id=\"8d828dd\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"2885\" data-end=\"3080\">Il s'agit d'\u00e9valuer l'int\u00e9grit\u00e9 de la <strong data-start=\"2921\" data-end=\"2944\">syst\u00e8me de fermeture des flacons<\/strong> sans perforation pr\u00e9alable. Les flacons sont pr\u00e9par\u00e9s, scell\u00e9s, immerg\u00e9s dans le colorant et mis sous vide de la m\u00eame mani\u00e8re, puis inspect\u00e9s pour v\u00e9rifier que le colorant n'a pas p\u00e9n\u00e9tr\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fed1035 e-flex e-con-boxed e-con e-parent\" data-id=\"fed1035\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-7873f87 e-con-full e-flex e-con e-child\" data-id=\"7873f87\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-918ea08 e-con-full e-flex e-con e-child\" data-id=\"918ea08\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3f376ab elementor-widget__width-initial elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"3f376ab\" data-element_type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><a href=\"https:\/\/www.leakagetester.com\/fr\/lt-02-leak-tester\/\" target=\"_blank\" tabindex=\"-1\"><img decoding=\"async\" width=\"120\" height=\"92\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/10\/LT-02-Vacuum-Leak-Tester.webp\" class=\"attachment-full size-full wp-image-2099\" alt=\"\" \/><\/a><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\"><a href=\"https:\/\/www.leakagetester.com\/fr\/lt-02-leak-tester\/\" target=\"_blank\">Testeur de fuites LT-02<\/a><\/h3><p class=\"elementor-image-box-description\">La premi\u00e8re g\u00e9n\u00e9ration de testeur de fuite automatique con\u00e7u par CELL Instruments, qui est l&#039;unit\u00e9 la plus vendue \u00e0 ce jour.<\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b584e4d elementor-widget__width-initial elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"b584e4d\" data-element_type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><a href=\"https:\/\/www.leakagetester.com\/fr\/lt-03-leak-tester\/\" target=\"_blank\" tabindex=\"-1\"><img loading=\"lazy\" decoding=\"async\" width=\"120\" height=\"94\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/10\/LT-03-leak-tester.webp\" class=\"attachment-full size-full wp-image-2095\" alt=\"Testeur de fuite LT-03 Petit\" \/><\/a><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\"><a href=\"https:\/\/www.leakagetester.com\/fr\/lt-03-leak-tester\/\" target=\"_blank\">Testeur de fuites LT-03<\/a><\/h3><p class=\"elementor-image-box-description\">Le dernier testeur de fuite automatique qui \u00e9volue toujours, avec un syst\u00e8me de contr\u00f4le avanc\u00e9, un affichage et des fonctionnalit\u00e9s d&#039;impression et de logiciel en option.<\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3384222 e-con-full e-flex e-con e-child\" data-id=\"3384222\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-705671e elementor-widget elementor-widget-heading\" data-id=\"705671e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Equipement d&#039;essai<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d765a06 elementor-widget elementor-widget-text-editor\" data-id=\"d765a06\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"3140\" data-end=\"3378\">L'ex\u00e9cution pr\u00e9cise de la norme ISO 8871-5 exige une r\u00e9gulation coh\u00e9rente de la pression, une synchronisation pr\u00e9cise et une \u00e9tanch\u00e9it\u00e9 fiable. Cell Instruments recommande l'utilisation du<strong data-start=\"3283\" data-end=\"3311\">\u00a0Testeur d'\u00e9tanch\u00e9it\u00e9 de flacon<\/strong>, Le syst\u00e8me est con\u00e7u sp\u00e9cifiquement pour r\u00e9pondre aux normes ISO, y compris la norme ISO 8871-5.<\/p><p class=\"\" data-start=\"3380\" data-end=\"3393\"><strong>Caract\u00e9ristiques principales :<\/strong><\/p><ul><li data-start=\"3396\" data-end=\"3449\">Contr\u00f4le automatis\u00e9 de la pression (27 kPa en dessous de la pression atmosph\u00e9rique)<\/li><li data-start=\"3396\" data-end=\"3449\">Fonctions de synchronisation pr\u00e9cises<\/li><li data-start=\"3396\" data-end=\"3449\">Compatible avec les syst\u00e8mes de fermeture de flacons de 13 mm et 20 mm<\/li><li data-start=\"3396\" data-end=\"3449\">Convient \u00e0 la fois aux m\u00e9thodes d'auto-\u00e9tanch\u00e9it\u00e9 et de p\u00e9n\u00e9tration des colorants<\/li><\/ul><p class=\"\" data-start=\"3591\" data-end=\"3775\">Gr\u00e2ce \u00e0 l'automatisation et \u00e0 la coh\u00e9rence, cette <strong data-start=\"3629\" data-end=\"3658\">machine de test d'\u00e9tanch\u00e9it\u00e9 des flacons<\/strong> r\u00e9duit les erreurs de l'op\u00e9rateur et garantit la r\u00e9p\u00e9tabilit\u00e9, ce qui est essentiel pour assurer la conformit\u00e9 aux r\u00e9glementations et la s\u00e9curit\u00e9 des produits.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-897aaf5 e-flex e-con-boxed e-con e-parent\" data-id=\"897aaf5\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-23d08cc elementor-widget elementor-widget-heading\" data-id=\"23d08cc\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Applications dans les industries m\u00e9dicales et pharmaceutiques<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-48e4aa6 elementor-widget elementor-widget-text-editor\" data-id=\"48e4aa6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"3844\" data-end=\"3899\">Le <strong data-start=\"3848\" data-end=\"3866\">test d'\u00e9tanch\u00e9it\u00e9 des flacons<\/strong> en vertu de la norme ISO 8871-5 est essentielle :<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-32a66fc e-con-full e-flex e-con e-child\" data-id=\"32a66fc\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bc8b02f elementor-widget__width-initial elementor-widget elementor-widget-heading\" data-id=\"bc8b02f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">M\u00e9dicaments injectables multidoses<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cf25ff0 elementor-widget__width-initial elementor-widget elementor-widget-heading\" data-id=\"cf25ff0\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conteneurs \u00e0 vaccins<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0ca050f elementor-widget__width-initial elementor-widget elementor-widget-heading\" data-id=\"0ca050f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conditionnement de m\u00e9dicaments par voie intraveineuse<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6aebdd4 elementor-widget__width-initial elementor-widget elementor-widget-heading\" data-id=\"6aebdd4\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Flacons de diagnostic<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8c1e6fc elementor-widget elementor-widget-text-editor\" data-id=\"8c1e6fc\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"3997\" data-end=\"4155\"><strong data-start=\"3997\" data-end=\"4026\">Ing\u00e9nieurs charg\u00e9s du contr\u00f4le de la qualit\u00e9<\/strong>, <strong data-start=\"4028\" data-end=\"4046\">Scientifiques de la R&amp;D<\/strong>, et <strong data-start=\"4052\" data-end=\"4072\">\u00e9quipes r\u00e9glementaires<\/strong> s'appuient sur ces tests pour valider l'int\u00e9grit\u00e9 de la fermeture du conteneur avant sa mise sur le march\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-75d00f67 e-con-full e-flex e-con e-parent\" data-id=\"75d00f67\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6d8146b5 elementor-widget__width-inherit elementor-widget elementor-widget-heading\" data-id=\"6d8146b5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Meilleures pratiques pour la mise en \u0153uvre de la norme ISO 8871-5<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-68472fc8 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"68472fc8\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">S'aligner pleinement sur la norme ISO 8871-5 :<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4781572a animated-slow elementor-widget-divider--view-line elementor-invisible elementor-widget elementor-widget-divider\" data-id=\"4781572a\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;}\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d671e1c elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"d671e1c\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul data-start=\"4241\" data-end=\"4547\"><li class=\"\" data-start=\"4241\" data-end=\"4299\"><p class=\"\" data-start=\"4243\" data-end=\"4299\">Utiliser des flacons, des bouchons et des joints \u00e0 sertir conformes \u00e0 la norme ISO 8362.<\/p><\/li><li class=\"\" data-start=\"4300\" data-end=\"4354\"><p class=\"\" data-start=\"4302\" data-end=\"4354\">Veiller \u00e0 ce que les environnements d'essai soient propres et exempts de particules.<\/p><\/li><li class=\"\" data-start=\"4355\" data-end=\"4432\"><p class=\"\" data-start=\"4357\" data-end=\"4432\">\u00c9viter les tensioactifs dans la solution de bleu de m\u00e9thyl\u00e8ne pour ne pas fausser les r\u00e9sultats.<\/p><\/li><li class=\"\" data-start=\"4433\" data-end=\"4471\"><p class=\"\" data-start=\"4435\" data-end=\"4471\">\u00c9talonner r\u00e9guli\u00e8rement les chambres \u00e0 vide.<\/p><\/li><li class=\"\" data-start=\"4472\" data-end=\"4547\"><p class=\"\" data-start=\"4474\" data-end=\"4547\">Enregistrer toutes les donn\u00e9es d'inspection conform\u00e9ment aux exigences de documentation de la norme.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4828799 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"4828799\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Cell Instruments fournit non seulement des \u00e9quipements, mais aussi <strong data-start=\"4603\" data-end=\"4625\">formation technique<\/strong>, <strong data-start=\"4627\" data-end=\"4655\">solutions d'essai personnalis\u00e9es<\/strong>, et <strong data-start=\"4661\" data-end=\"4684\">services d'automatisation<\/strong> pour aider les laboratoires et les fabricants \u00e0 r\u00e9aliser efficacement des tests conformes \u00e0 la norme ISO.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-563ef868 e-con-full e-flex e-con e-parent\" data-id=\"563ef868\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6a7ad6cf elementor-widget elementor-widget-heading\" data-id=\"6a7ad6cf\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">FAQ sur l'ISO 8871-5<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7333fe2d e-con-full e-flex e-con e-child\" data-id=\"7333fe2d\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dd759c2 elementor-widget elementor-widget-n-accordion\" data-id=\"dd759c2\" data-element_type=\"widget\" data-settings=\"{&quot;max_items_expended&quot;:&quot;multiple&quot;,&quot;default_state&quot;:&quot;expanded&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens avec Enter ou Space, fermez-les avec Escape et naviguez avec les touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2320\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-2320\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><h3 class=\"e-n-accordion-item-title-text\"> 1. Quels sont les crit\u00e8res d'\u00e9valuation de la norme ISO 8871-5 ? <\/h3><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2320\" class=\"elementor-element elementor-element-e471aee e-con-full e-flex e-con e-child\" data-id=\"e471aee\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7b578c7 elementor-widget elementor-widget-text-editor\" data-id=\"7b578c7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"5395\" data-end=\"5545\">La norme ISO 8871-5 \u00e9value l'auto-\u00e9tanch\u00e9it\u00e9 et l'int\u00e9grit\u00e9 du joint des fermetures en \u00e9lastom\u00e8re utilis\u00e9es dans les flacons pharmaceutiques.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2321\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2321\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><h3 class=\"e-n-accordion-item-title-text\"> 2. Comment fonctionne la proc\u00e9dure de test d'\u00e9tanch\u00e9it\u00e9 des flacons ? <\/h3><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2321\" class=\"elementor-element elementor-element-7ce5868 e-con-full e-flex e-con e-child\" data-id=\"7ce5868\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c9878c6 elementor-widget elementor-widget-text-editor\" data-id=\"c9878c6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"5547\" data-end=\"5731\">Elle implique des ponctions r\u00e9p\u00e9t\u00e9es des bouchons \u00e0 l'aide d'une aiguille, l'immersion dans un colorant et l'exposition au vide pour d\u00e9tecter les fuites par une inspection visuelle.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2322\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2322\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><h3 class=\"e-n-accordion-item-title-text\"> 3. Pourquoi l'auto-\u00e9tanch\u00e9it\u00e9 de la fermeture en caoutchouc du flacon est-elle importante ? <\/h3><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2322\" class=\"elementor-element elementor-element-dcfefc8 e-con-full e-flex e-con e-child\" data-id=\"dcfefc8\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-72b4879 elementor-widget elementor-widget-text-editor\" data-id=\"72b4879\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"5733\" data-end=\"5900\">Il garantit que le flacon reste st\u00e9rile apr\u00e8s de multiples ponctions, en particulier dans les r\u00e9cipients multidoses.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2323\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2323\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><h3 class=\"e-n-accordion-item-title-text\"> 4. Quel est l'\u00e9quipement n\u00e9cessaire pour effectuer des tests conform\u00e9ment \u00e0 la norme ISO 8871-5 ? <\/h3><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2323\" class=\"elementor-element elementor-element-0bfbdd9 e-flex e-con-boxed e-con e-child\" data-id=\"0bfbdd9\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-34a8313 elementor-widget elementor-widget-text-editor\" data-id=\"34a8313\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"5902\" data-end=\"6160\">Vous avez besoin de flacons et de bouchons conformes \u00e0 la norme ISO 8362, de colorant bleu de m\u00e9thyl\u00e8ne, d'aiguilles hypodermiques et d'une chambre \u00e0 vide. A <strong data-start=\"6090\" data-end=\"6119\">machine de test d'\u00e9tanch\u00e9it\u00e9 des flacons<\/strong> comme le LSSD-01 simplifie le processus.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2324\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2324\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><h3 class=\"e-n-accordion-item-title-text\"> 5. Cell Instruments peut-il contribuer \u00e0 l'automatisation et \u00e0 la formation pour ces tests ? <\/h3><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2324\" class=\"elementor-element elementor-element-d9b9e08 e-flex e-con-boxed e-con e-child\" data-id=\"d9b9e08\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ccffa35 elementor-widget elementor-widget-text-editor\" data-id=\"ccffa35\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"flex max-w-full flex-col grow\"><div class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+&amp;]:mt-5\" dir=\"auto\" data-message-author-role=\"assistant\" data-message-id=\"ac04b2fb-b909-4342-bffc-6922592acb69\" data-message-model-slug=\"gpt-4o\"><div class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[3px]\"><div class=\"markdown prose dark:prose-invert w-full break-words light\"><p class=\"\" data-start=\"6162\" data-end=\"6381\">Oui. Cell Instruments propose des syst\u00e8mes personnalisables, des mises \u00e0 niveau de l'automatisation et une formation sp\u00e9cialis\u00e9e pour aider les clients \u00e0 r\u00e9pondre aux exigences des tests ISO.<\/p><\/div><\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3a2b679a e-flex e-con-boxed e-con e-parent\" data-id=\"3a2b679a\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-38014124 elementor-widget elementor-widget-heading\" data-id=\"38014124\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Vous recherchez un \u00e9quipement fiable de d\u00e9tection des fuites dans les flacons ISO 8871-5 ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-53b530f2 elementor-widget elementor-widget-text-editor\" data-id=\"53b530f2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0Ne manquez pas l\u2019occasion d\u2019optimiser vos processus de contr\u00f4le qualit\u00e9 avec des \u00e9quipements de pointe.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d0c06b6 elementor-mobile-align-center elementor-align-center elementor-widget elementor-widget-button\" data-id=\"5d0c06b6\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/fr\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contactez-nous<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6021db4e e-flex e-con-boxed e-con e-parent\" data-id=\"6021db4e\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-474e3b4e elementor-widget elementor-widget-heading\" data-id=\"474e3b4e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Informations connexes<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ba2452d elementor-posts__hover-none elementor-grid-2 elementor-grid-tablet-2 elementor-grid-mobile-1 elementor-posts--thumbnail-top elementor-widget elementor-widget-posts\" data-id=\"6ba2452d\" data-element_type=\"widget\" data-settings=\"{&quot;cards_row_gap&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:80,&quot;sizes&quot;:[]},&quot;cards_row_gap_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:71,&quot;sizes&quot;:[]},&quot;cards_row_gap_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:30,&quot;sizes&quot;:[]},&quot;cards_columns&quot;:&quot;2&quot;,&quot;cards_columns_tablet&quot;:&quot;2&quot;,&quot;cards_columns_mobile&quot;:&quot;1&quot;}\" data-widget_type=\"posts.cards\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-posts-container elementor-posts elementor-posts--skin-cards elementor-grid\">\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-2253 post type-post status-publish format-standard hentry category-vacuum-leak-test tag-astm-d3078 tag-astm-d4991 tag-vacuum-leak-tester\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h4 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/www.leakagetester.com\/fr\/lt-02-leak-tester\/\" >\n\t\t\t\tTesteur de fuites LT-02\t\t\t<\/a>\n\t\t<\/h4>\n\t\t\t\t<div class=\"elementor-post__excerpt\">\n\t\t\t<p> Le <strong>Testeur de fuites LT-02<\/strong> est une solution de test sous vide automatique hautes performances sp\u00e9cialement con\u00e7ue pour d\u00e9tecter les fuites dans les emballages flexibles, en particulier dans les applications o\u00f9 le gaz de l&#039;espace de t\u00eate est pr\u00e9sent. Cet \u00e9quipement est couramment utilis\u00e9 dans les industries agroalimentaires, pharmaceutiques et autres o\u00f9 la fiabilit\u00e9 de l&#039;emballage est essentielle pour maintenir la qualit\u00e9 du produit.<\/p>\n\t\t<\/div>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/www.leakagetester.com\/fr\/lt-02-leak-tester\/\" aria-label=\"Read more about LT-02 Leak Tester\" tabindex=\"-1\" >\n\t\t\tEn savoir plus\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-2179 post type-post status-publish format-standard hentry category-vacuum-leak-test tag-astm-d3078 tag-astm-d4991 tag-vacuum-leak-tester\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h4 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/www.leakagetester.com\/fr\/lt-03-leak-tester\/\" >\n\t\t\t\tTesteur de fuites LT-03\t\t\t<\/a>\n\t\t<\/h4>\n\t\t\t\t<div class=\"elementor-post__excerpt\">\n\t\t\t<p>Le testeur d&#039;\u00e9tanch\u00e9it\u00e9 LT-03 est un appareil de pointe con\u00e7u pour une \u00e9valuation rigoureuse de l&#039;int\u00e9grit\u00e9 de l&#039;\u00e9tanch\u00e9it\u00e9 des emballages dans divers secteurs. Cet \u00e9quipement est essentiel pour v\u00e9rifier que l&#039;emballage conserve ses capacit\u00e9s de protection, pr\u00e9servant ainsi la qualit\u00e9 et la s\u00e9curit\u00e9 du produit. Le LT-03 est particuli\u00e8rement adapt\u00e9 aux applications impliquant des emballages flexibles, mais il est \u00e9galement adaptable pour tester des mat\u00e9riaux non flexibles et rigides gr\u00e2ce \u00e0 sa conception personnalisable.<\/p>\n\t\t<\/div>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/www.leakagetester.com\/fr\/lt-03-leak-tester\/\" aria-label=\"Read more about LT-03 Leak Tester\" tabindex=\"-1\" >\n\t\t\tEn savoir plus\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<\/div>\n\t\t\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 8871-5 Pi\u00e8ces en \u00e9lastom\u00e8re pour m\u00e9dicaments parent\u00e9raux et pour dispositifs \u00e0 usage pharmaceutiquePartie 5:Exigences fonctionnelles et essais Demander un devis R\u00e9sum\u00e9 de la norme Le maintien de la st\u00e9rilit\u00e9 des m\u00e9dicaments parent\u00e9raux est une pr\u00e9occupation essentielle des industries pharmaceutiques et des dispositifs m\u00e9dicaux. L'ISO 8871-5 fournit une approche d'essai structur\u00e9e pour \u00e9valuer l'int\u00e9grit\u00e9 fonctionnelle des fermetures en \u00e9lastom\u00e8re utilis\u00e9es avec [...]","protected":false},"author":2,"featured_media":0,"parent":2112,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-4067","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ISO 8871-5 Vial Leak Test for Vial Rubber Closure Self-Sealing - Leakage Tester<\/title>\n<meta name=\"description\" content=\"Understand ISO 8871-5 for evaluating vial rubber closure self-sealing using the vial leak test procedure. Discover reliable testing methods with Cell Instruments\u2019 vial leak testing machines.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.leakagetester.com\/fr\/standards\/iso-8871-5\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ISO 8871-5 Vial Leak Test for Vial Rubber Closure Self-Sealing Measurement\" \/>\n<meta property=\"og:description\" content=\"Understand ISO 8871-5 for evaluating vial rubber closure self-sealing using the vial leak test procedure. Discover reliable testing methods with Cell Instruments\u2019 vial leak testing machines.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.leakagetester.com\/fr\/standards\/iso-8871-5\/\" \/>\n<meta property=\"og:site_name\" content=\"Leakage Tester\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/cellinstruments\/\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-22T06:46:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"ISO 8871-5 Vial Leak Test for Vial Rubber Closure Self-Sealing Measurement\" \/>\n<meta name=\"twitter:description\" content=\"Understand ISO 8871-5 for evaluating vial rubber closure self-sealing using the vial leak test procedure. Discover reliable testing methods with Cell Instruments\u2019 vial leak testing machines.\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/\",\"url\":\"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/\",\"name\":\"ISO 8871-5 Vial Leak Test for Vial Rubber Closure Self-Sealing - Leakage Tester\",\"isPartOf\":{\"@id\":\"https:\/\/www.leakagetester.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp\",\"datePublished\":\"2025-04-22T05:58:51+00:00\",\"dateModified\":\"2025-04-22T06:46:01+00:00\",\"description\":\"Understand ISO 8871-5 for evaluating vial rubber closure self-sealing using the vial leak test procedure. Discover reliable testing methods with Cell Instruments\u2019 vial leak testing machines.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#primaryimage\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.leakagetester.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Standards\",\"item\":\"https:\/\/www.leakagetester.com\/standards\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ISO 8871-5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.leakagetester.com\/#website\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"name\":\"Leakage Testing Solutions\",\"description\":\"CELL INSTRUMENTS CO., LTD.\",\"publisher\":{\"@id\":\"https:\/\/www.leakagetester.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.leakagetester.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.leakagetester.com\/#organization\",\"name\":\"Cell Instruments Co., Ltd.\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"width\":1269,\"height\":342,\"caption\":\"Cell Instruments Co., Ltd.\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/cellinstruments\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ISO 8871-5 Test d'\u00e9tanch\u00e9it\u00e9 pour flacon \u00e0 fermeture en caoutchouc auto-obturante - Testeur d'\u00e9tanch\u00e9it\u00e9","description":"Comprendre la norme ISO 8871-5 pour l'\u00e9valuation de l'auto-\u00e9tanch\u00e9it\u00e9 des bouchons en caoutchouc des flacons \u00e0 l'aide de la proc\u00e9dure de test d'\u00e9tanch\u00e9it\u00e9 des flacons. D\u00e9couvrez des m\u00e9thodes de test fiables avec les machines de test d'\u00e9tanch\u00e9it\u00e9 des flacons de Cell Instruments.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.leakagetester.com\/fr\/standards\/iso-8871-5\/","og_locale":"fr_FR","og_type":"article","og_title":"ISO 8871-5 Vial Leak Test for Vial Rubber Closure Self-Sealing Measurement","og_description":"Understand ISO 8871-5 for evaluating vial rubber closure self-sealing using the vial leak test procedure. Discover reliable testing methods with Cell Instruments\u2019 vial leak testing machines.","og_url":"https:\/\/www.leakagetester.com\/fr\/standards\/iso-8871-5\/","og_site_name":"Leakage Tester","article_publisher":"https:\/\/www.facebook.com\/cellinstruments\/","article_modified_time":"2025-04-22T06:46:01+00:00","og_image":[{"width":600,"height":200,"url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_title":"ISO 8871-5 Vial Leak Test for Vial Rubber Closure Self-Sealing Measurement","twitter_description":"Understand ISO 8871-5 for evaluating vial rubber closure self-sealing using the vial leak test procedure. Discover reliable testing methods with Cell Instruments\u2019 vial leak testing machines.","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/","url":"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/","name":"ISO 8871-5 Test d'\u00e9tanch\u00e9it\u00e9 pour flacon \u00e0 fermeture en caoutchouc auto-obturante - Testeur d'\u00e9tanch\u00e9it\u00e9","isPartOf":{"@id":"https:\/\/www.leakagetester.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#primaryimage"},"image":{"@id":"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#primaryimage"},"thumbnailUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp","datePublished":"2025-04-22T05:58:51+00:00","dateModified":"2025-04-22T06:46:01+00:00","description":"Comprendre la norme ISO 8871-5 pour l'\u00e9valuation de l'auto-\u00e9tanch\u00e9it\u00e9 des bouchons en caoutchouc des flacons \u00e0 l'aide de la proc\u00e9dure de test d'\u00e9tanch\u00e9it\u00e9 des flacons. D\u00e9couvrez des m\u00e9thodes de test fiables avec les machines de test d'\u00e9tanch\u00e9it\u00e9 des flacons de Cell Instruments.","breadcrumb":{"@id":"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#primaryimage","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ISO-8871-5.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.leakagetester.com\/standards\/iso-8871-5\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.leakagetester.com\/"},{"@type":"ListItem","position":2,"name":"Standards","item":"https:\/\/www.leakagetester.com\/standards\/"},{"@type":"ListItem","position":3,"name":"ISO 8871-5"}]},{"@type":"WebSite","@id":"https:\/\/www.leakagetester.com\/#website","url":"https:\/\/www.leakagetester.com\/","name":"Solutions de test d&#039;\u00e9tanch\u00e9it\u00e9","description":"INSTRUMENTS CELLULAIRES CO., LTD.","publisher":{"@id":"https:\/\/www.leakagetester.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.leakagetester.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.leakagetester.com\/#organization","name":"Cell Instruments Co., Ltd.","url":"https:\/\/www.leakagetester.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","width":1269,"height":342,"caption":"Cell Instruments Co., Ltd."},"image":{"@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/cellinstruments\/"]}]}},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"leakagetester","author_link":"https:\/\/www.leakagetester.com\/fr\/author\/leakagetester\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 8871-5 Elastomeric parts for parenterals and for devices for pharmaceutical usePart 5:Functional requirements and testing Request a Quote Standard Summary Maintaining the sterility of parenteral drugs is a critical concern in the pharmaceutical and medical device industries. ISO 8871-5 provides a structured testing approach for assessing the functional integrity of elastomeric closures used with\u2026","_links":{"self":[{"href":"https:\/\/www.leakagetester.com\/fr\/wp-json\/wp\/v2\/pages\/4067","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.leakagetester.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.leakagetester.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/fr\/wp-json\/wp\/v2\/comments?post=4067"}],"version-history":[{"count":0,"href":"https:\/\/www.leakagetester.com\/fr\/wp-json\/wp\/v2\/pages\/4067\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/fr\/wp-json\/wp\/v2\/pages\/2112"}],"wp:attachment":[{"href":"https:\/\/www.leakagetester.com\/fr\/wp-json\/wp\/v2\/media?parent=4067"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}