{"id":4110,"date":"2025-05-26T17:13:43","date_gmt":"2025-05-26T09:13:43","guid":{"rendered":"https:\/\/www.leakagetester.com\/?page_id=4110"},"modified":"2025-05-27T08:28:34","modified_gmt":"2025-05-27T00:28:34","slug":"iso-11040-4","status":"publish","type":"page","link":"https:\/\/www.leakagetester.com\/fr\/standards\/iso-11040-4\/","title":{"rendered":"ISO 11040-4"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"4110\" class=\"elementor elementor-4110\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4987d4e6 e-flex e-con-boxed e-con e-parent\" data-id=\"4987d4e6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7b47303e elementor-widget elementor-widget-text-editor\" data-id=\"7b47303e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b290316 e-con-full e-flex e-con e-parent\" data-id=\"b290316\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-5c5c9cd e-con-full e-flex e-con e-child\" data-id=\"5c5c9cd\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0192e7d elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"0192e7d\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dad80d0 e-con-full e-flex e-con e-child\" data-id=\"dad80d0\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3d5573c elementor-widget elementor-widget-heading\" data-id=\"3d5573c\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h5 class=\"elementor-heading-title elementor-size-default\">Seringues pr\u00e9remplies<br>Partie 4 : F\u00fbts en verre pour produits injectables et seringues sous-assembl\u00e9es st\u00e9rilis\u00e9es pr\u00eates \u00e0 \u00eatre remplies<\/h5>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-14bfcde elementor-tablet-align-center elementor-mobile-align-center elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-button\" data-id=\"14bfcde\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:200}\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/fr\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Demander un devis<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7db034b e-flex e-con-boxed e-con e-parent\" data-id=\"7db034b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-0b99b3c e-con-full e-flex e-con e-child\" data-id=\"0b99b3c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dee3d55 elementor-widget elementor-widget-heading\" data-id=\"dee3d55\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">R\u00e9sum\u00e9 standard<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-070771a elementor-widget elementor-widget-text-editor\" data-id=\"070771a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1249\" data-end=\"1545\">Le test d'\u00e9tanch\u00e9it\u00e9 de la seringue a pour but de v\u00e9rifier les \u00e9l\u00e9ments suivants <strong data-start=\"1290\" data-end=\"1346\">r\u00e9sistance aux fuites de liquides des syst\u00e8mes de fermeture de seringues<\/strong> dans des conditions de pression d\u00e9finies. Selon le <em data-start=\"1395\" data-end=\"1420\">Annexe G2 de la norme ISO 11040-4<\/em>Ce test simule la surpression interne (typiquement 110 kPa) que les seringues peuvent subir pendant le remplissage ou le transport.<\/p>\n<p data-start=\"1249\" data-end=\"1545\">Ce test \u00e9value \u00e0 la fois <strong data-start=\"1572\" data-end=\"1590\">les protections d'aiguille<\/strong> et <strong data-start=\"1595\" data-end=\"1607\">capuchons d'embout<\/strong>Ces fermetures restent s\u00fbres et ne fuient pas sous l'effet du stress.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5e86730 e-con-full e-flex e-con e-child\" data-id=\"5e86730\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ae0f79e elementor-widget elementor-widget-image\" data-id=\"ae0f79e\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"200\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp\" class=\"attachment-medium size-medium wp-image-4116\" alt=\"ISO 11040-4\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp 600w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4-18x6.webp 18w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b86c929 elementor-widget elementor-widget-text-editor\" data-id=\"b86c929\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Cette \u00e9valuation est essentielle pour le contr\u00f4le de la qualit\u00e9 des produits pharmaceutiques, la pr\u00e9vention de la contamination et la pr\u00e9servation de la pr\u00e9cision du dosage.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5a6238d e-flex e-con-boxed e-con e-parent\" data-id=\"5a6238d\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-84ad92e elementor-widget elementor-widget-heading\" data-id=\"84ad92e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">M\u00e9thode d'essai de fuite de liquide du syst\u00e8me de fermeture de seringue<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b15d017 elementor-widget elementor-widget-text-editor\" data-id=\"b15d017\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1859\" data-end=\"1908\"><strong data-start=\"1859\" data-end=\"1908\">Principales \u00e9tapes de l'essai (conform\u00e9ment \u00e0 l'annexe G2 de la norme ISO 11040-4) :<\/strong><\/p>\n<ul>\n<li data-start=\"1912\" data-end=\"2038\"><strong data-start=\"1912\" data-end=\"1935\">Pr\u00e9paration des \u00e9chantillons :<\/strong> Utiliser des seringues st\u00e9rilis\u00e9es, sous-assembl\u00e9es et pr\u00eates \u00e0 \u00eatre remplies. \u00c9viter de d\u00e9ranger le bouchon avant le test.<\/li>\n<li data-start=\"2041\" data-end=\"2125\"><strong data-start=\"2041\" data-end=\"2060\">P\u00e9riode d'attente :<\/strong> Il faut attendre au moins 12 heures entre la fixation du bouchon et le test.<\/li>\n<li data-start=\"2128\" data-end=\"2245\"><strong data-start=\"2128\" data-end=\"2140\">Garniture :<\/strong> Remplir la seringue entre 1\/3 et 2\/3 de son volume nominal avec de l'eau distill\u00e9e ou de puret\u00e9 \u00e9quivalente.<\/li>\n<li data-start=\"2248\" data-end=\"2399\"><strong data-start=\"2248\" data-end=\"2267\">Pressurisation :<\/strong> Appliquer <strong data-start=\"2274\" data-end=\"2285\">110 kPa<\/strong> pression \u00e0 l'aide d'air comprim\u00e9 ou d'un <strong data-start=\"2321\" data-end=\"2374\">machine universelle d'essai de traction et de compression<\/strong>. Tenir pour <strong data-start=\"2385\" data-end=\"2398\">5 secondes<\/strong>.<\/li>\n<li data-start=\"2402\" data-end=\"2537\"><strong data-start=\"2402\" data-end=\"2417\">Contr\u00f4le :<\/strong> Observez les fuites de liquide pendant et apr\u00e8s le test. Les fuites apparaissent sous forme de gouttelettes visibles sur la surface ext\u00e9rieure de la fermeture.<\/li>\n<li data-start=\"2540\" data-end=\"2654\"><strong data-start=\"2540\" data-end=\"2558\">Crit\u00e8res de r\u00e9ussite :<\/strong> Aucune gouttelette ne doit \u00eatre visible et la fermeture (capuchon ou protection de l'aiguille) doit rester en place.<\/li>\n<\/ul>\n<blockquote data-start=\"2656\" data-end=\"2793\">\n<p data-start=\"2658\" data-end=\"2793\">Le test est valable pour les seringues et les sous-ensembles st\u00e9riles. L'inspection visuelle est essentielle pour d\u00e9terminer les r\u00e9sultats de r\u00e9ussite ou d'\u00e9chec.<\/p>\n<\/blockquote>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e2cd145 e-flex e-con-boxed e-con e-parent\" data-id=\"e2cd145\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-384e6ec elementor-widget elementor-widget-heading\" data-id=\"384e6ec\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00c9quipement essentiel pour le test d'\u00e9tanch\u00e9it\u00e9 des seringues<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4cd2af2 elementor-widget elementor-widget-text-editor\" data-id=\"4cd2af2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2850\" data-end=\"2893\">L'\u00e9quipement mis en place pour ce test comprend<\/p>\n<ul>\n<li data-start=\"2897\" data-end=\"2985\"><strong data-start=\"2897\" data-end=\"2941\">Testeur universel de traction et de compression<\/strong> ou <strong data-start=\"2945\" data-end=\"2985\">syst\u00e8me de pressurisation de l'air comprim\u00e9<\/strong><\/li>\n<li data-start=\"2988\" data-end=\"3038\"><strong data-start=\"2988\" data-end=\"3006\">Porte-seringue<\/strong> avec un m\u00e9canisme de fermeture s\u00e9curis\u00e9<\/li>\n<li data-start=\"3041\" data-end=\"3116\"><strong data-start=\"3041\" data-end=\"3071\">Manom\u00e8tre ou logiciel<\/strong> capable d'atteindre et de maintenir 110 kPa<\/li>\n<li data-start=\"3119\" data-end=\"3208\"><strong data-start=\"3119\" data-end=\"3165\">Syst\u00e8me d'acquisition de donn\u00e9es \u00e0 haute fr\u00e9quence d'\u00e9chantillonnage<\/strong> (recommand\u00e9 500 Hz pour les mesures de cr\u00eate)<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4bdb15f e-flex e-con-boxed e-con e-parent\" data-id=\"4bdb15f\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f031e68 elementor-widget elementor-widget-heading\" data-id=\"f031e68\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Solutions de Cell Instruments :<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9831b44 elementor-widget elementor-widget-text-editor\" data-id=\"9831b44\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3210\" data-end=\"3472\">Effectuer des tests d'\u00e9tanch\u00e9it\u00e9 des seringues conform\u00e9ment \u00e0 la norme ISO 11040-4, <strong data-start=\"3307\" data-end=\"3373\">Cell Instruments propose des plates-formes de test \u00e0 seringue personnalisables<\/strong>Nos syst\u00e8mes sont compatibles avec les m\u00e9thodes d'application de l'air comprim\u00e9 et de la force m\u00e9canique. Nos syst\u00e8mes garantissent :<\/p>\n<ul>\n<li data-start=\"3476\" data-end=\"3517\"><strong data-start=\"3476\" data-end=\"3517\">Contr\u00f4le pr\u00e9cis de la pression interne<\/strong><\/li>\n<li data-start=\"3520\" data-end=\"3560\"><strong data-start=\"3520\" data-end=\"3560\">Echantillonnage haute fr\u00e9quence jusqu'\u00e0 500 Hz<\/strong><\/li>\n<li data-start=\"3563\" data-end=\"3610\"><strong data-start=\"3563\" data-end=\"3610\">Conformit\u00e9 totale avec les proc\u00e9dures d'essai ISO<\/strong><\/li>\n<li data-start=\"3613\" data-end=\"3675\"><strong data-start=\"3613\" data-end=\"3649\">Fonctions de documentation automatis\u00e9e<\/strong> pour des rapports pr\u00eats \u00e0 \u00eatre audit\u00e9s<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d0f3e8d e-flex e-con-boxed e-con e-parent\" data-id=\"d0f3e8d\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-bdde50c e-con-full e-flex e-con e-child\" data-id=\"bdde50c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4b4c297 elementor-widget elementor-widget-heading\" data-id=\"4b4c297\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Solutions de Cell Instruments :<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f28aead elementor-widget elementor-widget-text-editor\" data-id=\"f28aead\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3210\" data-end=\"3472\">Effectuer des tests d'\u00e9tanch\u00e9it\u00e9 des seringues conform\u00e9ment \u00e0 la norme ISO 11040-4, <strong data-start=\"3307\" data-end=\"3373\">Cell Instruments propose des plates-formes de test \u00e0 seringue personnalisables<\/strong>Nos syst\u00e8mes sont compatibles avec les m\u00e9thodes d'application de l'air comprim\u00e9 et de la force m\u00e9canique. Nos syst\u00e8mes garantissent :<\/p>\n<ul>\n<li data-start=\"3476\" data-end=\"3517\"><strong data-start=\"3476\" data-end=\"3517\">Contr\u00f4le pr\u00e9cis de la pression interne<\/strong><\/li>\n<li data-start=\"3520\" data-end=\"3560\"><strong data-start=\"3520\" data-end=\"3560\">Echantillonnage haute fr\u00e9quence jusqu'\u00e0 500 Hz<\/strong><\/li>\n<li data-start=\"3563\" data-end=\"3610\"><strong data-start=\"3563\" data-end=\"3610\">Conformit\u00e9 totale avec les proc\u00e9dures d'essai ISO<\/strong><\/li>\n<li data-start=\"3613\" data-end=\"3675\"><strong data-start=\"3613\" data-end=\"3649\">Fonctions de documentation automatis\u00e9e<\/strong> pour des rapports pr\u00eats \u00e0 \u00eatre audit\u00e9s<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-513146a e-flex e-con-boxed e-con e-parent\" data-id=\"513146a\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-f93229d e-con-full e-flex e-con e-child\" data-id=\"f93229d\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ad6986d elementor-widget elementor-widget-heading\" data-id=\"ad6986d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Enregistrement des donn\u00e9es et documentation<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b242490 elementor-widget elementor-widget-text-editor\" data-id=\"b242490\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3720\" data-end=\"3781\">Selon le <em data-start=\"3733\" data-end=\"3743\">Annexe G2<\/em>Un rapport d'essai complet doit comprendre<\/p>\n<ul>\n<li data-start=\"3785\" data-end=\"3835\"><strong data-start=\"3785\" data-end=\"3805\">Pression appliqu\u00e9e<\/strong> (kPa) ou force \u00e9quivalente (N)<\/li>\n<li data-start=\"3838\" data-end=\"3867\"><strong data-start=\"3838\" data-end=\"3867\">Nombre de seringues test\u00e9es<\/strong><\/li>\n<li data-start=\"3870\" data-end=\"3905\"><strong data-start=\"3870\" data-end=\"3905\">Nombre d'\u00e9chantillons r\u00e9ussis\/\u00e9checs<\/strong><\/li>\n<li data-start=\"3908\" data-end=\"3945\"><strong data-start=\"3908\" data-end=\"3945\">Observations visuelles ou d\u00e9viations<\/strong><\/li>\n<li data-start=\"3946\" data-end=\"4011\">\n<p data-start=\"3948\" data-end=\"4011\"><strong data-start=\"3948\" data-end=\"3984\">Tra\u00e7abilit\u00e9 des param\u00e8tres de configuration<\/strong> (manuellement ou par logiciel)<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4013\" data-end=\"4193\">En documentant les conditions d'essai et les r\u00e9sultats, les fabricants d\u00e9montrent leur conformit\u00e9 \u00e0 la norme ISO 11040-4 et s'assurent que <strong data-start=\"4123\" data-end=\"4150\">tra\u00e7abilit\u00e9 r\u00e9glementaire<\/strong>-un must pour les syst\u00e8mes de qualit\u00e9 pharmaceutiques.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c13f4f1 e-con-full e-flex e-con e-child\" data-id=\"c13f4f1\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fa7bb58 elementor-widget elementor-widget-heading\" data-id=\"fa7bb58\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Calcul de la force interne<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e89f57a elementor-widget elementor-widget-text-editor\" data-id=\"e89f57a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4232\" data-end=\"4417\">Pour les installations appliquant une force m\u00e9canique au lieu d'une pression d'air, le nombre requis de <strong data-start=\"4311\" data-end=\"4324\">force (F)<\/strong> pour simuler une pression interne de 110 kPa peut \u00eatre calcul\u00e9e en utilisant les formules de la norme ISO 11040-4 :<\/p>\n<blockquote data-start=\"4419\" data-end=\"4459\">\n<p data-start=\"4421\" data-end=\"4459\"><strong data-start=\"4421\" data-end=\"4448\">F = p \u00d7 \u03c0\/4 \u00d7 d\u00b2 \u00d7 10-\u00b3<\/strong><br data-start=\"4448\" data-end=\"4451\" \/>O\u00f9 ?<\/p>\n<\/blockquote>\n<ul>\n<li data-start=\"4462\" data-end=\"4488\"><strong data-start=\"4462\" data-end=\"4467\">F<\/strong> = Force en Newtons<\/li>\n<li data-start=\"4491\" data-end=\"4519\"><strong data-start=\"4491\" data-end=\"4496\">p<\/strong> = Pression (110 kPa)<\/li>\n<li data-start=\"4522\" data-end=\"4562\"><strong data-start=\"4522\" data-end=\"4527\">d<\/strong> = Diam\u00e8tre interne de la seringue (mm)<\/li>\n<\/ul>\n<p data-start=\"4564\" data-end=\"4647\">Ce calcul permet de garantir <strong data-start=\"4594\" data-end=\"4623\">r\u00e9plication pr\u00e9cise des tests<\/strong> et l'\u00e9talonnage des appareils.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 11040-4 Seringues pr\u00e9rempliesPartie 4 : Barils en verre pour produits injectables et seringues sous-assembl\u00e9es st\u00e9rilis\u00e9es pr\u00eates \u00e0 \u00eatre remplies Demander un devis R\u00e9sum\u00e9 de la norme Le test d'\u00e9tanch\u00e9it\u00e9 des seringues vise \u00e0 v\u00e9rifier la r\u00e9sistance aux fuites de liquide des syst\u00e8mes de fermeture des seringues dans des conditions de pression d\u00e9finies. Selon l'annexe G2 de l'ISO 11040-4, le test simule une surpression interne (typiquement 110 kPa) [...]","protected":false},"author":2,"featured_media":0,"parent":2112,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-4110","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ISO 11040-4 Syringe Leak Test - Closure System Liquid Leakage<\/title>\n<meta name=\"description\" content=\"Syringe leak test per ISO 11040-4 Annex G2 to ensure closure integrity. Discover the test method, apparatus.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.leakagetester.com\/fr\/standards\/iso-11040-4\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ISO 11040-4 Syringe Leak Test - Closure System Liquid Leakage\" \/>\n<meta property=\"og:description\" content=\"Syringe leak test per ISO 11040-4 Annex G2 to ensure closure integrity. Discover the test method, apparatus.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.leakagetester.com\/fr\/standards\/iso-11040-4\/\" \/>\n<meta property=\"og:site_name\" content=\"Leakage Tester\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/cellinstruments\/\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-27T00:28:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/\",\"url\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/\",\"name\":\"ISO 11040-4 Syringe Leak Test - Closure System Liquid Leakage\",\"isPartOf\":{\"@id\":\"https:\/\/www.leakagetester.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp\",\"datePublished\":\"2025-05-26T09:13:43+00:00\",\"dateModified\":\"2025-05-27T00:28:34+00:00\",\"description\":\"Syringe leak test per ISO 11040-4 Annex G2 to ensure closure integrity. Discover the test method, apparatus.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#primaryimage\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.leakagetester.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Standards\",\"item\":\"https:\/\/www.leakagetester.com\/standards\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ISO 11040-4\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.leakagetester.com\/#website\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"name\":\"Leakage Testing Solutions\",\"description\":\"CELL INSTRUMENTS CO., LTD.\",\"publisher\":{\"@id\":\"https:\/\/www.leakagetester.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.leakagetester.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.leakagetester.com\/#organization\",\"name\":\"Cell Instruments Co., Ltd.\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"width\":1269,\"height\":342,\"caption\":\"Cell Instruments Co., Ltd.\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/cellinstruments\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ISO 11040-4 Test d'\u00e9tanch\u00e9it\u00e9 de seringue - Fuite de liquide du syst\u00e8me de fermeture","description":"Test d'\u00e9tanch\u00e9it\u00e9 de seringue selon ISO 11040-4 Annexe G2 pour garantir l'int\u00e9grit\u00e9 de la fermeture. D\u00e9couvrez la m\u00e9thode de test, l'appareil.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.leakagetester.com\/fr\/standards\/iso-11040-4\/","og_locale":"fr_FR","og_type":"article","og_title":"ISO 11040-4 Syringe Leak Test - Closure System Liquid Leakage","og_description":"Syringe leak test per ISO 11040-4 Annex G2 to ensure closure integrity. Discover the test method, apparatus.","og_url":"https:\/\/www.leakagetester.com\/fr\/standards\/iso-11040-4\/","og_site_name":"Leakage Tester","article_publisher":"https:\/\/www.facebook.com\/cellinstruments\/","article_modified_time":"2025-05-27T00:28:34+00:00","og_image":[{"width":600,"height":200,"url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/","url":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/","name":"ISO 11040-4 Test d'\u00e9tanch\u00e9it\u00e9 de seringue - Fuite de liquide du syst\u00e8me de fermeture","isPartOf":{"@id":"https:\/\/www.leakagetester.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#primaryimage"},"image":{"@id":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#primaryimage"},"thumbnailUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp","datePublished":"2025-05-26T09:13:43+00:00","dateModified":"2025-05-27T00:28:34+00:00","description":"Test d'\u00e9tanch\u00e9it\u00e9 de seringue selon ISO 11040-4 Annexe G2 pour garantir l'int\u00e9grit\u00e9 de la fermeture. D\u00e9couvrez la m\u00e9thode de test, l'appareil.","breadcrumb":{"@id":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#primaryimage","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.leakagetester.com\/"},{"@type":"ListItem","position":2,"name":"Standards","item":"https:\/\/www.leakagetester.com\/standards\/"},{"@type":"ListItem","position":3,"name":"ISO 11040-4"}]},{"@type":"WebSite","@id":"https:\/\/www.leakagetester.com\/#website","url":"https:\/\/www.leakagetester.com\/","name":"Solutions de test d&#039;\u00e9tanch\u00e9it\u00e9","description":"INSTRUMENTS CELLULAIRES CO., LTD.","publisher":{"@id":"https:\/\/www.leakagetester.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.leakagetester.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.leakagetester.com\/#organization","name":"Cell Instruments Co., Ltd.","url":"https:\/\/www.leakagetester.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","width":1269,"height":342,"caption":"Cell Instruments Co., Ltd."},"image":{"@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/cellinstruments\/"]}]}},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"leakagetester","author_link":"https:\/\/www.leakagetester.com\/fr\/author\/leakagetester\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 11040-4 Prefilled syringesPart 4: Glass barrels for injectables and sterilized subassembled syringes ready for filling Request a Quote Standard Summary The syringe leak test aims to verify the liquid leakage resistance of syringe closure systems under defined pressure conditions. According to Annex G2 of ISO 11040-4, the test simulates internal overpressure (typically 110 kPa)\u2026","_links":{"self":[{"href":"https:\/\/www.leakagetester.com\/fr\/wp-json\/wp\/v2\/pages\/4110","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.leakagetester.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.leakagetester.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/fr\/wp-json\/wp\/v2\/comments?post=4110"}],"version-history":[{"count":0,"href":"https:\/\/www.leakagetester.com\/fr\/wp-json\/wp\/v2\/pages\/4110\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/fr\/wp-json\/wp\/v2\/pages\/2112"}],"wp:attachment":[{"href":"https:\/\/www.leakagetester.com\/fr\/wp-json\/wp\/v2\/media?parent=4110"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}