{"id":4110,"date":"2025-05-26T17:13:43","date_gmt":"2025-05-26T09:13:43","guid":{"rendered":"https:\/\/www.leakagetester.com\/?page_id=4110"},"modified":"2025-05-27T08:28:34","modified_gmt":"2025-05-27T00:28:34","slug":"iso-11040-4","status":"publish","type":"page","link":"https:\/\/www.leakagetester.com\/it\/standards\/iso-11040-4\/","title":{"rendered":"ISO 11040-4"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"4110\" class=\"elementor elementor-4110\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4987d4e6 e-flex e-con-boxed e-con e-parent\" data-id=\"4987d4e6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7b47303e elementor-widget elementor-widget-text-editor\" data-id=\"7b47303e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b290316 e-con-full e-flex e-con e-parent\" data-id=\"b290316\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-5c5c9cd e-con-full e-flex e-con e-child\" data-id=\"5c5c9cd\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0192e7d elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"0192e7d\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dad80d0 e-con-full e-flex e-con e-child\" data-id=\"dad80d0\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3d5573c elementor-widget elementor-widget-heading\" data-id=\"3d5573c\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h5 class=\"elementor-heading-title elementor-size-default\">Siringhe preriempite<br>Part 4: Glass barrels for injectables and sterilized subassembled syringes ready for filling<\/h5>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-14bfcde elementor-tablet-align-center elementor-mobile-align-center elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-button\" data-id=\"14bfcde\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:200}\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/it\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Richiesta di preventivo<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7db034b e-flex e-con-boxed e-con e-parent\" data-id=\"7db034b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-0b99b3c e-con-full e-flex e-con e-child\" data-id=\"0b99b3c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dee3d55 elementor-widget elementor-widget-heading\" data-id=\"dee3d55\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Riepilogo standard<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-070771a elementor-widget elementor-widget-text-editor\" data-id=\"070771a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1249\" data-end=\"1545\">The syringe leak test aims to verify the <strong data-start=\"1290\" data-end=\"1346\">liquid leakage resistance of syringe closure systems<\/strong> under defined pressure conditions. According to <em data-start=\"1395\" data-end=\"1420\">Annex G2 of ISO 11040-4<\/em>, the test simulates internal overpressure (typically 110 kPa) that syringes may experience during filling or transportation.<\/p>\n<p data-start=\"1249\" data-end=\"1545\">This test evaluates both <strong data-start=\"1572\" data-end=\"1590\">needle shields<\/strong> e <strong data-start=\"1595\" data-end=\"1607\">tip caps<\/strong>, ensuring these closures remain secure and do not leak under stress.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5e86730 e-con-full e-flex e-con e-child\" data-id=\"5e86730\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ae0f79e elementor-widget elementor-widget-image\" data-id=\"ae0f79e\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"200\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp\" class=\"attachment-medium size-medium wp-image-4116\" alt=\"ISO 11040-4\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp 600w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4-18x6.webp 18w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b86c929 elementor-widget elementor-widget-text-editor\" data-id=\"b86c929\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Such evaluation is vital for pharmaceutical quality control, preventing contamination, and safeguarding dosage accuracy.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5a6238d e-flex e-con-boxed e-con e-parent\" data-id=\"5a6238d\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-84ad92e elementor-widget elementor-widget-heading\" data-id=\"84ad92e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Syringe Closure System Liquid Leakage Test Method<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b15d017 elementor-widget elementor-widget-text-editor\" data-id=\"b15d017\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1859\" data-end=\"1908\"><strong data-start=\"1859\" data-end=\"1908\">Key Test Steps (as per ISO 11040-4 Annex G2):<\/strong><\/p>\n<ul>\n<li data-start=\"1912\" data-end=\"2038\"><strong data-start=\"1912\" data-end=\"1935\">Sample Preparation:<\/strong> Use sterilized, subassembled syringes ready for filling. Avoid disturbing the closure before the test.<\/li>\n<li data-start=\"2041\" data-end=\"2125\"><strong data-start=\"2041\" data-end=\"2060\">Waiting Period:<\/strong> Allow a minimum of 12 hours between closure setting and testing.<\/li>\n<li data-start=\"2128\" data-end=\"2245\"><strong data-start=\"2128\" data-end=\"2140\">Filling:<\/strong> Fill the syringe to between 1\/3 and 2\/3 of its nominal volume with distilled or equivalent-purity water.<\/li>\n<li data-start=\"2248\" data-end=\"2399\"><strong data-start=\"2248\" data-end=\"2267\">Pressurization:<\/strong> Apply <strong data-start=\"2274\" data-end=\"2285\">110 kPa<\/strong> pressure using compressed air or a <strong data-start=\"2321\" data-end=\"2374\">universal tensile and compression testing machine<\/strong>. Hold for <strong data-start=\"2385\" data-end=\"2398\">5 seconds<\/strong>.<\/li>\n<li data-start=\"2402\" data-end=\"2537\"><strong data-start=\"2402\" data-end=\"2417\">Monitoring:<\/strong> Observe for liquid leakage during and after the test. Leakage appears as visible droplets on the outer closure surface.<\/li>\n<li data-start=\"2540\" data-end=\"2654\"><strong data-start=\"2540\" data-end=\"2558\">Pass Criteria:<\/strong> No droplets should be visible, and the closure (tip cap or needle shield) must remain in place.<\/li>\n<\/ul>\n<blockquote data-start=\"2656\" data-end=\"2793\">\n<p data-start=\"2658\" data-end=\"2793\">The testing is valid for both syringe barrels and sterile subassemblies. Visual inspection is essential to determine pass\/fail results.<\/p>\n<\/blockquote>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e2cd145 e-flex e-con-boxed e-con e-parent\" data-id=\"e2cd145\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-384e6ec elementor-widget elementor-widget-heading\" data-id=\"384e6ec\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Essential Equipment for Syringe Leak Testing<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4cd2af2 elementor-widget elementor-widget-text-editor\" data-id=\"4cd2af2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2850\" data-end=\"2893\">The equipment setup for this test includes:<\/p>\n<ul>\n<li data-start=\"2897\" data-end=\"2985\"><strong data-start=\"2897\" data-end=\"2941\">Universal tensile and compression tester<\/strong> o <strong data-start=\"2945\" data-end=\"2985\">compressed air pressurization system<\/strong><\/li>\n<li data-start=\"2988\" data-end=\"3038\"><strong data-start=\"2988\" data-end=\"3006\">Syringe holder<\/strong> with a secure sealing mechanism<\/li>\n<li data-start=\"3041\" data-end=\"3116\"><strong data-start=\"3041\" data-end=\"3071\">Pressure gauge or software<\/strong> capable of achieving and maintaining 110 kPa<\/li>\n<li data-start=\"3119\" data-end=\"3208\"><strong data-start=\"3119\" data-end=\"3165\">High-sampling rate data acquisition system<\/strong> (recommended 500 Hz for peak measurements)<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4bdb15f e-flex e-con-boxed e-con e-parent\" data-id=\"4bdb15f\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f031e68 elementor-widget elementor-widget-heading\" data-id=\"f031e68\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Cell Instruments' Solutions:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9831b44 elementor-widget elementor-widget-text-editor\" data-id=\"9831b44\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3210\" data-end=\"3472\">To perform syringe leak tests in accordance with ISO 11040-4, <strong data-start=\"3307\" data-end=\"3373\">Cell Instruments offers customizable syringe testing platforms<\/strong>, compatible with both compressed air and mechanical force application methods. Our systems ensure:<\/p>\n<ul>\n<li data-start=\"3476\" data-end=\"3517\"><strong data-start=\"3476\" data-end=\"3517\">Accurate control of internal pressure<\/strong><\/li>\n<li data-start=\"3520\" data-end=\"3560\"><strong data-start=\"3520\" data-end=\"3560\">High-frequency sampling up to 500 Hz<\/strong><\/li>\n<li data-start=\"3563\" data-end=\"3610\"><strong data-start=\"3563\" data-end=\"3610\">Full compliance with ISO testing procedures<\/strong><\/li>\n<li data-start=\"3613\" data-end=\"3675\"><strong data-start=\"3613\" data-end=\"3649\">Automated documentation features<\/strong> for audit-ready reporting<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d0f3e8d e-flex e-con-boxed e-con e-parent\" data-id=\"d0f3e8d\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-bdde50c e-con-full e-flex e-con e-child\" data-id=\"bdde50c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4b4c297 elementor-widget elementor-widget-heading\" data-id=\"4b4c297\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Cell Instruments' Solutions:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f28aead elementor-widget elementor-widget-text-editor\" data-id=\"f28aead\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3210\" data-end=\"3472\">To perform syringe leak tests in accordance with ISO 11040-4, <strong data-start=\"3307\" data-end=\"3373\">Cell Instruments offers customizable syringe testing platforms<\/strong>, compatible with both compressed air and mechanical force application methods. Our systems ensure:<\/p>\n<ul>\n<li data-start=\"3476\" data-end=\"3517\"><strong data-start=\"3476\" data-end=\"3517\">Accurate control of internal pressure<\/strong><\/li>\n<li data-start=\"3520\" data-end=\"3560\"><strong data-start=\"3520\" data-end=\"3560\">High-frequency sampling up to 500 Hz<\/strong><\/li>\n<li data-start=\"3563\" data-end=\"3610\"><strong data-start=\"3563\" data-end=\"3610\">Full compliance with ISO testing procedures<\/strong><\/li>\n<li data-start=\"3613\" data-end=\"3675\"><strong data-start=\"3613\" data-end=\"3649\">Automated documentation features<\/strong> for audit-ready reporting<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-513146a e-flex e-con-boxed e-con e-parent\" data-id=\"513146a\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-f93229d e-con-full e-flex e-con e-child\" data-id=\"f93229d\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ad6986d elementor-widget elementor-widget-heading\" data-id=\"ad6986d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Data Recording and Documentation<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b242490 elementor-widget elementor-widget-text-editor\" data-id=\"b242490\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3720\" data-end=\"3781\">Secondo <em data-start=\"3733\" data-end=\"3743\">Annex G2<\/em>, a complete test report must include:<\/p>\n<ul>\n<li data-start=\"3785\" data-end=\"3835\"><strong data-start=\"3785\" data-end=\"3805\">Applied pressure<\/strong> (kPa) or equivalent force (N)<\/li>\n<li data-start=\"3838\" data-end=\"3867\"><strong data-start=\"3838\" data-end=\"3867\">Number of tested syringes<\/strong><\/li>\n<li data-start=\"3870\" data-end=\"3905\"><strong data-start=\"3870\" data-end=\"3905\">Number of passed\/failed samples<\/strong><\/li>\n<li data-start=\"3908\" data-end=\"3945\"><strong data-start=\"3908\" data-end=\"3945\">Visual observations or deviations<\/strong><\/li>\n<li data-start=\"3946\" data-end=\"4011\">\n<p data-start=\"3948\" data-end=\"4011\"><strong data-start=\"3948\" data-end=\"3984\">Traceability of setup parameters<\/strong> (manually or via software)<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4013\" data-end=\"4193\">By documenting test conditions and outcomes, manufacturers demonstrate compliance with ISO 11040-4 and ensure <strong data-start=\"4123\" data-end=\"4150\">regulatory traceability<\/strong>\u2014a must for pharmaceutical quality systems.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c13f4f1 e-con-full e-flex e-con e-child\" data-id=\"c13f4f1\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fa7bb58 elementor-widget elementor-widget-heading\" data-id=\"fa7bb58\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Calculating Internal Force<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e89f57a elementor-widget elementor-widget-text-editor\" data-id=\"e89f57a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4232\" data-end=\"4417\">For facilities applying mechanical force instead of air pressure, the required <strong data-start=\"4311\" data-end=\"4324\">force (F)<\/strong> to simulate 110 kPa internal pressure can be calculated using the formulas from ISO 11040-4:<\/p>\n<blockquote data-start=\"4419\" data-end=\"4459\">\n<p data-start=\"4421\" data-end=\"4459\"><strong data-start=\"4421\" data-end=\"4448\">F = p \u00d7 \u03c0\/4 \u00d7 d\u00b2 \u00d7 10\u207b\u00b3<\/strong><br data-start=\"4448\" data-end=\"4451\" \/>Where:<\/p>\n<\/blockquote>\n<ul>\n<li data-start=\"4462\" data-end=\"4488\"><strong data-start=\"4462\" data-end=\"4467\">F<\/strong> = Force in Newtons<\/li>\n<li data-start=\"4491\" data-end=\"4519\"><strong data-start=\"4491\" data-end=\"4496\">p<\/strong> = Pressure (110 kPa)<\/li>\n<li data-start=\"4522\" data-end=\"4562\"><strong data-start=\"4522\" data-end=\"4527\">d<\/strong> = Syringe internal diameter (mm)<\/li>\n<\/ul>\n<p data-start=\"4564\" data-end=\"4647\">This calculation helps ensure <strong data-start=\"4594\" data-end=\"4623\">accurate test replication<\/strong> and device calibration.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 11040-4 Prefilled syringesPart 4: Glass barrels for injectables and sterilized subassembled syringes ready for filling Request a Quote Standard Summary The syringe leak test aims to verify the liquid leakage resistance of syringe closure systems under defined pressure conditions. According to Annex G2 of ISO 11040-4, the test simulates internal overpressure (typically 110 kPa) [&#8230;]","protected":false},"author":2,"featured_media":0,"parent":2112,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-4110","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ISO 11040-4 Syringe Leak Test - Closure System Liquid Leakage<\/title>\n<meta name=\"description\" content=\"Syringe leak test per ISO 11040-4 Annex G2 to ensure closure integrity. Discover the test method, apparatus.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.leakagetester.com\/it\/standards\/iso-11040-4\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ISO 11040-4 Syringe Leak Test - Closure System Liquid Leakage\" \/>\n<meta property=\"og:description\" content=\"Syringe leak test per ISO 11040-4 Annex G2 to ensure closure integrity. Discover the test method, apparatus.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.leakagetester.com\/it\/standards\/iso-11040-4\/\" \/>\n<meta property=\"og:site_name\" content=\"Leakage Tester\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/cellinstruments\/\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-27T00:28:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/\",\"url\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/\",\"name\":\"ISO 11040-4 Syringe Leak Test - Closure System Liquid Leakage\",\"isPartOf\":{\"@id\":\"https:\/\/www.leakagetester.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp\",\"datePublished\":\"2025-05-26T09:13:43+00:00\",\"dateModified\":\"2025-05-27T00:28:34+00:00\",\"description\":\"Syringe leak test per ISO 11040-4 Annex G2 to ensure closure integrity. Discover the test method, apparatus.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#primaryimage\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.leakagetester.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Standards\",\"item\":\"https:\/\/www.leakagetester.com\/standards\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ISO 11040-4\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.leakagetester.com\/#website\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"name\":\"Leakage Testing Solutions\",\"description\":\"CELL INSTRUMENTS CO., LTD.\",\"publisher\":{\"@id\":\"https:\/\/www.leakagetester.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.leakagetester.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.leakagetester.com\/#organization\",\"name\":\"Cell Instruments Co., Ltd.\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"width\":1269,\"height\":342,\"caption\":\"Cell Instruments Co., Ltd.\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/cellinstruments\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ISO 11040-4 Syringe Leak Test - Closure System Liquid Leakage","description":"Syringe leak test per ISO 11040-4 Annex G2 to ensure closure integrity. Discover the test method, apparatus.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.leakagetester.com\/it\/standards\/iso-11040-4\/","og_locale":"it_IT","og_type":"article","og_title":"ISO 11040-4 Syringe Leak Test - Closure System Liquid Leakage","og_description":"Syringe leak test per ISO 11040-4 Annex G2 to ensure closure integrity. Discover the test method, apparatus.","og_url":"https:\/\/www.leakagetester.com\/it\/standards\/iso-11040-4\/","og_site_name":"Leakage Tester","article_publisher":"https:\/\/www.facebook.com\/cellinstruments\/","article_modified_time":"2025-05-27T00:28:34+00:00","og_image":[{"width":600,"height":200,"url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Tempo di lettura stimato":"3 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/","url":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/","name":"ISO 11040-4 Syringe Leak Test - Closure System Liquid Leakage","isPartOf":{"@id":"https:\/\/www.leakagetester.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#primaryimage"},"image":{"@id":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#primaryimage"},"thumbnailUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp","datePublished":"2025-05-26T09:13:43+00:00","dateModified":"2025-05-27T00:28:34+00:00","description":"Syringe leak test per ISO 11040-4 Annex G2 to ensure closure integrity. Discover the test method, apparatus.","breadcrumb":{"@id":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#primaryimage","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.leakagetester.com\/"},{"@type":"ListItem","position":2,"name":"Standards","item":"https:\/\/www.leakagetester.com\/standards\/"},{"@type":"ListItem","position":3,"name":"ISO 11040-4"}]},{"@type":"WebSite","@id":"https:\/\/www.leakagetester.com\/#website","url":"https:\/\/www.leakagetester.com\/","name":"Soluzioni per le prove di tenuta","description":"CELL INSTRUMENTS CO.","publisher":{"@id":"https:\/\/www.leakagetester.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.leakagetester.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/www.leakagetester.com\/#organization","name":"Cell Instruments Co.","url":"https:\/\/www.leakagetester.com\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","width":1269,"height":342,"caption":"Cell Instruments Co., Ltd."},"image":{"@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/cellinstruments\/"]}]}},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"leakagetester","author_link":"https:\/\/www.leakagetester.com\/it\/author\/leakagetester\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 11040-4 Prefilled syringesPart 4: Glass barrels for injectables and sterilized subassembled syringes ready for filling Request a Quote Standard Summary The syringe leak test aims to verify the liquid leakage resistance of syringe closure systems under defined pressure conditions. According to Annex G2 of ISO 11040-4, the test simulates internal overpressure (typically 110 kPa)&hellip;","_links":{"self":[{"href":"https:\/\/www.leakagetester.com\/it\/wp-json\/wp\/v2\/pages\/4110","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.leakagetester.com\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.leakagetester.com\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/it\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/it\/wp-json\/wp\/v2\/comments?post=4110"}],"version-history":[{"count":0,"href":"https:\/\/www.leakagetester.com\/it\/wp-json\/wp\/v2\/pages\/4110\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/it\/wp-json\/wp\/v2\/pages\/2112"}],"wp:attachment":[{"href":"https:\/\/www.leakagetester.com\/it\/wp-json\/wp\/v2\/media?parent=4110"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}