{"id":4039,"date":"2025-04-15T10:40:51","date_gmt":"2025-04-15T02:40:51","guid":{"rendered":"https:\/\/www.leakagetester.com\/?page_id=4039"},"modified":"2025-04-16T09:09:46","modified_gmt":"2025-04-16T01:09:46","slug":"astm-d6653","status":"publish","type":"page","link":"https:\/\/www.leakagetester.com\/nl\/standards\/astm-d6653\/","title":{"rendered":"ASTM D6653"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"4039\" class=\"elementor elementor-4039\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-40854497 e-con-full e-flex e-con e-parent\" data-id=\"40854497\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-7b6e2650 e-con-full e-flex e-con e-child\" data-id=\"7b6e2650\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1ed62b75 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"1ed62b75\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ASTM D6653<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-649c5ca3 e-con-full e-flex e-con e-child\" data-id=\"649c5ca3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-528d414f elementor-widget elementor-widget-heading\" data-id=\"528d414f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h5 class=\"elementor-heading-title elementor-size-default\">Test Methods for Determining the Effects of High Altitude on Packaging Systems by Vacuum Method<\/h5>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4227f1f3 elementor-tablet-align-center elementor-mobile-align-center elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-button\" data-id=\"4227f1f3\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:200}\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/nl\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Vraag een offerte aan<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7f37671f e-flex e-con-boxed e-con e-parent\" data-id=\"7f37671f\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-7479e6a9 e-con-full e-flex e-con e-child\" data-id=\"7479e6a9\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c1f01b8 elementor-widget elementor-widget-heading\" data-id=\"2c1f01b8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Standaard samenvatting<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a7ff4e2 elementor-widget elementor-widget-text-editor\" data-id=\"a7ff4e2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"500\" data-end=\"908\">High-altitude transport can significantly stress packaging systems. Whether you\u2019re in food, pharmaceuticals, or electronics, understanding how packaging behaves under reduced pressure is crucial for preventing product damage. <strong data-start=\"726\" data-end=\"740\">ASTM D6653<\/strong>, <em data-start=\"742\" data-end=\"848\">Standard Test Methods for Determining the Effects of High Altitude on Packaging Systems by Vacuum Method<\/em>, provides an effective framework for assessing these risks.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-58d7dfdf e-con-full e-flex e-con e-child\" data-id=\"58d7dfdf\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4aba77f5 elementor-widget elementor-widget-image\" data-id=\"4aba77f5\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/store.astm.org\/d6653_d6653m-13r21.html\" target=\"_blank\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"200\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ASTM-D6653-1.webp\" class=\"attachment-medium size-medium wp-image-4062\" alt=\"ASTM D6653\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ASTM-D6653-1.webp 600w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ASTM-D6653-1-18x6.webp 18w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-38d9a2dc e-flex e-con-boxed e-con e-parent\" data-id=\"38d9a2dc\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-22b1040c e-con-full e-flex e-con e-child\" data-id=\"22b1040c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c1b4a01 elementor-widget elementor-widget-heading\" data-id=\"2c1b4a01\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Standaardbeschrijving<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2dbe846b elementor-widget elementor-widget-text-editor\" data-id=\"2dbe846b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"1196\" data-end=\"1620\">ASTM D6653 is specifically designed to simulate the reduced pressure environment experienced during air transport or travel over high mountain passes. Packaging systems may expand, rupture, or leak when exposed to the pressure differential at altitudes as high as 5,791 meters (19,000 feet). This standard enables manufacturers and quality control professionals to evaluate the resilience of packaging under such conditions.<\/p>\n<p class=\"\" data-start=\"1196\" data-end=\"1620\"><span style=\"letter-spacing: 0px; word-spacing: 0em;\">The test is particularly useful in:<\/span><\/p>\n<ul>\n<li data-start=\"1660\" data-end=\"1693\"><strong data-start=\"1660\" data-end=\"1693\">Package design and validation<\/strong><\/li>\n<li data-start=\"1660\" data-end=\"1693\"><strong style=\"color: #555555; font-size: 14.4px;\" data-start=\"1696\" data-end=\"1723\">Engineering assessments<\/strong><\/li>\n<li data-start=\"1660\" data-end=\"1693\"><strong style=\"color: #555555; font-size: 14.4px;\" data-start=\"1726\" data-end=\"1752\">Leak integrity testing<\/strong><\/li>\n<li data-start=\"1660\" data-end=\"1693\"><strong style=\"color: #555555; font-size: 14.4px;\" data-start=\"1755\" data-end=\"1803\">Identifying weak points in packaging systems<\/strong><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-346b4bef e-con-full e-flex e-con e-child\" data-id=\"346b4bef\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7704d43d elementor-widget elementor-widget-image\" data-id=\"7704d43d\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.leakagetester.com\/nl\/glt-01-gross-leak-tester\/\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"580\" height=\"480\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ASTM-D6653-leak-testing-vacuum-method.webp\" class=\"attachment-large size-large wp-image-4046\" alt=\"ASTM D6653 leak testing vacuum method\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ASTM-D6653-leak-testing-vacuum-method.webp 580w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ASTM-D6653-leak-testing-vacuum-method-483x400.webp 483w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ASTM-D6653-leak-testing-vacuum-method-15x12.webp 15w\" sizes=\"(max-width: 580px) 100vw, 580px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3ae6b8a e-flex e-con-boxed e-con e-parent\" data-id=\"3ae6b8a\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-8f24e53 e-con-full e-flex e-con e-child\" data-id=\"8f24e53\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-6905cde e-con-full e-flex e-con e-child\" data-id=\"6905cde\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-61e733b elementor-widget elementor-widget-heading\" data-id=\"61e733b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Why High Altitude Package Integrity Testing Matters<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8704851 elementor-widget elementor-widget-text-editor\" data-id=\"8704851\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"1867\" data-end=\"1999\">When products travel in unpressurized aircraft compartments, they experience significant pressure drops. These pressure changes can:<\/p>\n<ul>\n<li data-start=\"2002\" data-end=\"2049\">Deform plastic containers or flexible pouches<\/li>\n<li data-start=\"2002\" data-end=\"2049\">Cause seal failures or ruptures<\/li>\n<li data-start=\"2002\" data-end=\"2049\">Lead to leaks that compromise product safety and shelf life<\/li>\n<\/ul>\n<p class=\"\" data-start=\"2149\" data-end=\"2411\"><strong data-start=\"2149\" data-end=\"2192\">High altitude package integrity testing<\/strong> using <strong data-start=\"2199\" data-end=\"2213\">ASTM D6653<\/strong> ensures packaging can withstand these conditions without failure. It&#8217;s a proactive measure, especially for high-value or sensitive goods such as sterile medical devices, food items, or electronics.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a52d762 e-con-full e-flex e-con e-child\" data-id=\"a52d762\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-70322f2 e-con-full e-flex e-con e-child\" data-id=\"70322f2\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-87996ce elementor-widget elementor-widget-image\" data-id=\"87996ce\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"580\" height=\"800\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/ASTM-D3078-Bubble-Leak-Test-580x800.webp\" class=\"attachment-large size-large wp-image-3753\" alt=\"ASTM D3078 Bubble Leak-test\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/ASTM-D3078-Bubble-Leak-Test-580x800.webp 580w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/ASTM-D3078-Bubble-Leak-Test-290x400.webp 290w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/ASTM-D3078-Bubble-Leak-Test-9x12.webp 9w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/11\/ASTM-D3078-Bubble-Leak-Test.webp 585w\" sizes=\"(max-width: 580px) 100vw, 580px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9ee25e2 e-flex e-con-boxed e-con e-parent\" data-id=\"9ee25e2\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-9a921cd e-con-full e-flex e-con e-child\" data-id=\"9a921cd\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5f08225 elementor-widget elementor-widget-heading\" data-id=\"5f08225\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Gedetailleerde beschrijving van het testproces<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9c9adad elementor-widget elementor-widget-text-editor\" data-id=\"9c9adad\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"2476\" data-end=\"2593\">One of the key components of this standard is the <strong data-start=\"2526\" data-end=\"2543\">vacuum method<\/strong>. Here\u2019s a step-by-step breakdown of how it works:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-124480d e-con-full e-flex e-con e-child\" data-id=\"124480d\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-549c9e0 elementor-widget elementor-widget-n-accordion\" data-id=\"549c9e0\" data-element_type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accordion. Open links with Enter or Space, close with Escape, and navigate with Arrow Keys\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-8870\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-8870\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 1. Test Setup and Conditioning <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-8870\" class=\"elementor-element elementor-element-a22bf0c e-con-full e-flex e-con e-child\" data-id=\"a22bf0c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-df3534e elementor-widget elementor-widget-text-editor\" data-id=\"df3534e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li data-start=\"2634\" data-end=\"2714\">Specimens must be conditioned at 5.6 \u00b1 2\u00b0C for at least 24 hours before testing.<\/li>\n<li data-start=\"2634\" data-end=\"2714\">An alternative standard atmosphere of 23 \u00b1 2\u00b0C is acceptable when required.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-8871\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-8871\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 2. Equipment Requirements <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-8871\" class=\"elementor-element elementor-element-61c7ef2 e-con-full e-flex e-con e-child\" data-id=\"61c7ef2\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b81c6c0 elementor-widget elementor-widget-text-editor\" data-id=\"b81c6c0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"2794\" data-end=\"2844\">The test requires:<\/p>\n<ul>\n<li data-start=\"2847\" data-end=\"2936\">A vacuum chamber capable of simulating altitude conditions (up to 4,877 m or 16,000 ft)<\/li>\n<li data-start=\"2847\" data-end=\"2936\">A vacuum gauge accurate to within 2%<\/li>\n<li data-start=\"2847\" data-end=\"2936\">Proper sealing valves and pressure control features<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-8872\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-8872\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 3. Testing Procedure <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-8872\" class=\"elementor-element elementor-element-c98a7e1 e-con-full e-flex e-con e-child\" data-id=\"c98a7e1\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3c566a8 elementor-widget elementor-widget-text-editor\" data-id=\"3c566a8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li data-start=\"3062\" data-end=\"3101\">Place the package inside the chamber.<\/li>\n<li data-start=\"3062\" data-end=\"3101\">Increase the vacuum to simulate altitude at a rate of 305 m (1,000 ft) per 30\u201360 seconds.<\/li>\n<li data-start=\"3062\" data-end=\"3101\">Maintain the simulated altitude for 60 minutes.<\/li>\n<li data-start=\"3062\" data-end=\"3101\">Slowly return the chamber to atmospheric pressure.<\/li>\n<li data-start=\"3062\" data-end=\"3101\">Remove and inspect the package for any deformation, leakage, or seal failure.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-13cb69b elementor-widget elementor-widget-text-editor\" data-id=\"13cb69b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"3384\" data-end=\"3526\">This test does not measure leak size or rate directly but instead provides qualitative results by observing packaging integrity post-exposure.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-897aaf5 e-flex e-con-boxed e-con e-parent\" data-id=\"897aaf5\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-23d08cc elementor-widget elementor-widget-heading\" data-id=\"23d08cc\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Vacuum Method Best Practices and Considerations<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-48e4aa6 elementor-widget elementor-widget-text-editor\" data-id=\"48e4aa6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"3586\" data-end=\"3696\">To ensure accurate and repeatable results when performing <strong data-start=\"3644\" data-end=\"3671\">ASTM D6653 leak testing<\/strong>, consider the following:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c84b6f9 e-flex e-con-boxed e-con e-parent\" data-id=\"c84b6f9\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-1f6d17f e-con-full e-flex e-con e-child\" data-id=\"1f6d17f\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d2b88ee elementor-widget__width-initial elementor-widget elementor-widget-icon-box\" data-id=\"d2b88ee\" data-element_type=\"widget\" data-widget_type=\"icon-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-icon-box-wrapper\">\n\n\t\t\t\n\t\t\t\t\t\t<div class=\"elementor-icon-box-content\">\n\n\t\t\t\t\t\t\t\t\t<h3 class=\"elementor-icon-box-title\">\n\t\t\t\t\t\t<span  >\n\t\t\t\t\t\t\tSelect representative samples\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/h3>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<p class=\"elementor-icon-box-description\">\n\t\t\t\t\t\tUse representative samples from production batches\t\t\t\t\t<\/p>\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-410ce2d elementor-widget__width-initial elementor-widget elementor-widget-icon-box\" data-id=\"410ce2d\" data-element_type=\"widget\" data-widget_type=\"icon-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-icon-box-wrapper\">\n\n\t\t\t\n\t\t\t\t\t\t<div class=\"elementor-icon-box-content\">\n\n\t\t\t\t\t\t\t\t\t<h3 class=\"elementor-icon-box-title\">\n\t\t\t\t\t\t<span  >\n\t\t\t\t\t\t\tRecord all test conditions\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/h3>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<p class=\"elementor-icon-box-description\">\n\t\t\t\t\t\tDocument all test parameters, including altitude simulation level, vacuum duration, and temperature conditions\t\t\t\t\t<\/p>\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2bbb974 elementor-widget__width-initial elementor-widget elementor-widget-icon-box\" data-id=\"2bbb974\" data-element_type=\"widget\" data-widget_type=\"icon-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-icon-box-wrapper\">\n\n\t\t\t\n\t\t\t\t\t\t<div class=\"elementor-icon-box-content\">\n\n\t\t\t\t\t\t\t\t\t<h3 class=\"elementor-icon-box-title\">\n\t\t\t\t\t\t<span  >\n\t\t\t\t\t\t\tBenchmark with other standards\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/h3>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<p class=\"elementor-icon-box-description\">\n\t\t\t\t\t\tCompare results against performance testing methods such as ASTM D4169 for a full evaluation of packaging durability\t\t\t\t\t<\/p>\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28426a7 elementor-widget__width-initial elementor-widget elementor-widget-icon-box\" data-id=\"28426a7\" data-element_type=\"widget\" data-widget_type=\"icon-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-icon-box-wrapper\">\n\n\t\t\t\n\t\t\t\t\t\t<div class=\"elementor-icon-box-content\">\n\n\t\t\t\t\t\t\t\t\t<h3 class=\"elementor-icon-box-title\">\n\t\t\t\t\t\t<span  >\n\t\t\t\t\t\t\tEnsure controlled, reliable testing\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/h3>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<p class=\"elementor-icon-box-description\">\n\t\t\t\t\t\tAlways perform tests in controlled conditions with reliable instrumentation\t\t\t\t\t<\/p>\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-75d00f67 e-con-full e-flex e-con e-parent\" data-id=\"75d00f67\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6d8146b5 elementor-widget elementor-widget-heading\" data-id=\"6d8146b5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Interpreting and Reporting Results<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1265644e e-con-full e-flex e-con e-child\" data-id=\"1265644e\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-714ec7e4 e-con-full e-flex e-con e-child\" data-id=\"714ec7e4\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4781572a animated-slow elementor-widget-divider--view-line elementor-invisible elementor-widget elementor-widget-divider\" data-id=\"4781572a\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;}\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28b2958 elementor-widget elementor-widget-heading\" data-id=\"28b2958\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">A packaging system is deemed successful if:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1c91798 elementor-widget elementor-widget-text-editor\" data-id=\"1c91798\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li data-start=\"4877\" data-end=\"4934\">The product remains intact without deformation or leaks<\/li>\n<li data-start=\"4877\" data-end=\"4934\">Seals and closures remain secure<\/li>\n<li data-start=\"4877\" data-end=\"4934\">No internal packaging is displaced or damaged<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4e3c6bd elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"4e3c6bd\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"\" data-start=\"5213\" data-end=\"5339\">This data helps stakeholders make informed decisions regarding packaging design, shipping methods, and overall product safety.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6ccbd4b e-con-full e-flex e-con e-child\" data-id=\"6ccbd4b\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c3ceade animated-slow elementor-widget-divider--view-line elementor-invisible elementor-widget elementor-widget-divider\" data-id=\"c3ceade\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;}\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-522debf elementor-widget elementor-widget-heading\" data-id=\"522debf\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Reports should include:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-afe62c7 elementor-widget elementor-widget-text-editor\" data-id=\"afe62c7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li class=\"\" data-start=\"5047\" data-end=\"5081\">\n<p class=\"\" data-start=\"5049\" data-end=\"5081\">Test conditions and deviations<\/p>\n<\/li>\n<li class=\"\" data-start=\"5082\" data-end=\"5126\">\n<p class=\"\" data-start=\"5084\" data-end=\"5126\">Description of the packaging and product<\/p>\n<\/li>\n<li class=\"\" data-start=\"5127\" data-end=\"5164\">\n<p class=\"\" data-start=\"5129\" data-end=\"5164\">Temperature and vacuum parameters<\/p>\n<\/li>\n<li class=\"\" data-start=\"5165\" data-end=\"5211\">\n<p class=\"\" data-start=\"5167\" data-end=\"5211\">Visual observations and failure modes if any<\/p>\n<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-563ef868 e-con-full e-flex e-con e-parent\" data-id=\"563ef868\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6a7ad6cf elementor-widget elementor-widget-heading\" data-id=\"6a7ad6cf\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Veelgestelde vragen over ASTM D3078<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7333fe2d e-con-full e-flex e-con e-child\" data-id=\"7333fe2d\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-553bdba7 elementor-widget__width-inherit elementor-widget elementor-widget-toggle\" data-id=\"553bdba7\" data-element_type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<h4 id=\"elementor-tab-title-1421\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-1421\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">1. What is ASTM D6653 used for?<\/a>\n\t\t\t\t\t<\/h4>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-1421\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-1421\"><p>ASTM D6653 assesses the impact of high-altitude pressure changes on packaging systems using a vacuum method.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<h4 id=\"elementor-tab-title-1422\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-1422\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">2. Why is vacuum method testing important for packaging?<\/a>\n\t\t\t\t\t<\/h4>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-1422\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-1422\"><p>It simulates altitude conditions to evaluate if a package can withstand pressure differentials without leaking or deforming.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<h4 id=\"elementor-tab-title-1423\" class=\"elementor-tab-title\" data-tab=\"3\" role=\"button\" aria-controls=\"elementor-tab-content-1423\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">3. What industries benefit most from ASTM D6653 testing?<\/a>\n\t\t\t\t\t<\/h4>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-1423\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"region\" aria-labelledby=\"elementor-tab-title-1423\"><p>Packaging for pharmaceuticals, electronics, food, and medical devices all benefit due to their sensitivity to air transport conditions.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<h4 id=\"elementor-tab-title-1424\" class=\"elementor-tab-title\" data-tab=\"4\" role=\"button\" aria-controls=\"elementor-tab-content-1424\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">4. How long should the vacuum be maintained during testing?<\/a>\n\t\t\t\t\t<\/h4>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-1424\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"region\" aria-labelledby=\"elementor-tab-title-1424\"><p>Typically, the vacuum is held for 60 minutes, but this can vary depending on product value and shipping conditions.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<h4 id=\"elementor-tab-title-1425\" class=\"elementor-tab-title\" data-tab=\"5\" role=\"button\" aria-controls=\"elementor-tab-content-1425\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">5. What equipment is recommended for ASTM D6653 testing?<\/a>\n\t\t\t\t\t<\/h4>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-1425\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"5\" role=\"region\" aria-labelledby=\"elementor-tab-title-1425\"><p>Cell Instruments&#8217; GLT-01 Gross Leak Tester is ideal, offering precision vacuum control and optional pressure decay integration.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3a2b679a e-flex e-con-boxed e-con e-parent\" data-id=\"3a2b679a\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-38014124 elementor-widget elementor-widget-heading\" data-id=\"38014124\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Looking for reliable ASTM D6653 leak detection equipment?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-53b530f2 elementor-widget elementor-widget-text-editor\" data-id=\"53b530f2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0Mis de kans niet om uw kwaliteitscontroleprocessen te optimaliseren met ultramoderne apparatuur.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d0c06b6 elementor-mobile-align-center elementor-align-center elementor-widget elementor-widget-button\" data-id=\"5d0c06b6\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/nl\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Neem contact met ons op<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ASTM D6653 Test Methods for Determining the Effects of High Altitude on Packaging Systems by Vacuum Method Request a Quote Standard Summary High-altitude transport can significantly stress packaging systems. Whether you\u2019re in food, pharmaceuticals, or electronics, understanding how packaging behaves under reduced pressure is crucial for preventing product damage. ASTM D6653, Standard Test Methods for [&#8230;]","protected":false},"author":2,"featured_media":0,"parent":2112,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-4039","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ASTM D6653 - Leakage Tester<\/title>\n<meta name=\"description\" content=\"Learn how to perform high altitude package integrity testing with ASTM D6653. This guide explains vacuum method testing and ensures packaging safety during air transport.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.leakagetester.com\/nl\/standards\/astm-d6653\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ASTM D6653 High Altitude Leak Testing Using the Vacuum Method\" \/>\n<meta property=\"og:description\" content=\"Learn how to perform high altitude package integrity testing with ASTM D6653. This guide explains vacuum method testing and ensures packaging safety during air transport.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.leakagetester.com\/nl\/standards\/astm-d6653\/\" \/>\n<meta property=\"og:site_name\" content=\"Leakage Tester\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/cellinstruments\/\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-16T01:09:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/12\/leakage-tester-banner.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"650\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"ASTM D6653 High Altitude Leak Testing Using the Vacuum Method\" \/>\n<meta name=\"twitter:description\" content=\"Learn how to perform high altitude package integrity testing with ASTM D6653. This guide explains vacuum method testing and ensures packaging safety during air transport.\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/12\/leakage-tester-banner.jpg\" \/>\n<meta name=\"twitter:label1\" content=\"Geschatte leestijd\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/astm-d6653\/\",\"url\":\"https:\/\/www.leakagetester.com\/standards\/astm-d6653\/\",\"name\":\"ASTM D6653 - Leakage Tester\",\"isPartOf\":{\"@id\":\"https:\/\/www.leakagetester.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/astm-d6653\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/astm-d6653\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ASTM-D6653-1.webp\",\"datePublished\":\"2025-04-15T02:40:51+00:00\",\"dateModified\":\"2025-04-16T01:09:46+00:00\",\"description\":\"Learn how to perform high altitude package integrity testing with ASTM D6653. This guide explains vacuum method testing and ensures packaging safety during air transport.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/astm-d6653\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.leakagetester.com\/standards\/astm-d6653\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/astm-d6653\/#primaryimage\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ASTM-D6653-1.webp\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ASTM-D6653-1.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/astm-d6653\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.leakagetester.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Standards\",\"item\":\"https:\/\/www.leakagetester.com\/standards\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ASTM D6653\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.leakagetester.com\/#website\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"name\":\"Leakage Testing Solutions\",\"description\":\"CELL INSTRUMENTS CO., LTD.\",\"publisher\":{\"@id\":\"https:\/\/www.leakagetester.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.leakagetester.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.leakagetester.com\/#organization\",\"name\":\"Cell Instruments Co., Ltd.\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"width\":1269,\"height\":342,\"caption\":\"Cell Instruments Co., Ltd.\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/cellinstruments\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ASTM D6653 - Leakage Tester","description":"Learn how to perform high altitude package integrity testing with ASTM D6653. This guide explains vacuum method testing and ensures packaging safety during air transport.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.leakagetester.com\/nl\/standards\/astm-d6653\/","og_locale":"nl_NL","og_type":"article","og_title":"ASTM D6653 High Altitude Leak Testing Using the Vacuum Method","og_description":"Learn how to perform high altitude package integrity testing with ASTM D6653. This guide explains vacuum method testing and ensures packaging safety during air transport.","og_url":"https:\/\/www.leakagetester.com\/nl\/standards\/astm-d6653\/","og_site_name":"Leakage Tester","article_publisher":"https:\/\/www.facebook.com\/cellinstruments\/","article_modified_time":"2025-04-16T01:09:46+00:00","og_image":[{"width":1000,"height":650,"url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/12\/leakage-tester-banner.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_title":"ASTM D6653 High Altitude Leak Testing Using the Vacuum Method","twitter_description":"Learn how to perform high altitude package integrity testing with ASTM D6653. This guide explains vacuum method testing and ensures packaging safety during air transport.","twitter_image":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/12\/leakage-tester-banner.jpg","twitter_misc":{"Geschatte leestijd":"4 minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.leakagetester.com\/standards\/astm-d6653\/","url":"https:\/\/www.leakagetester.com\/standards\/astm-d6653\/","name":"ASTM D6653 - Leakage Tester","isPartOf":{"@id":"https:\/\/www.leakagetester.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.leakagetester.com\/standards\/astm-d6653\/#primaryimage"},"image":{"@id":"https:\/\/www.leakagetester.com\/standards\/astm-d6653\/#primaryimage"},"thumbnailUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ASTM-D6653-1.webp","datePublished":"2025-04-15T02:40:51+00:00","dateModified":"2025-04-16T01:09:46+00:00","description":"Learn how to perform high altitude package integrity testing with ASTM D6653. This guide explains vacuum method testing and ensures packaging safety during air transport.","breadcrumb":{"@id":"https:\/\/www.leakagetester.com\/standards\/astm-d6653\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.leakagetester.com\/standards\/astm-d6653\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/www.leakagetester.com\/standards\/astm-d6653\/#primaryimage","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ASTM-D6653-1.webp","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/04\/ASTM-D6653-1.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.leakagetester.com\/standards\/astm-d6653\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.leakagetester.com\/"},{"@type":"ListItem","position":2,"name":"Standards","item":"https:\/\/www.leakagetester.com\/standards\/"},{"@type":"ListItem","position":3,"name":"ASTM D6653"}]},{"@type":"WebSite","@id":"https:\/\/www.leakagetester.com\/#website","url":"https:\/\/www.leakagetester.com\/","name":"Lekkagetestoplossingen","description":"CELL INSTRUMENTS CO., LTD.","publisher":{"@id":"https:\/\/www.leakagetester.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.leakagetester.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"},{"@type":"Organization","@id":"https:\/\/www.leakagetester.com\/#organization","name":"Cell Instruments Co., Ltd.","url":"https:\/\/www.leakagetester.com\/","logo":{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","width":1269,"height":342,"caption":"Cell Instruments Co., Ltd."},"image":{"@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/cellinstruments\/"]}]}},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"leakagetester","author_link":"https:\/\/www.leakagetester.com\/nl\/author\/leakagetester\/"},"uagb_comment_info":0,"uagb_excerpt":"ASTM D6653 Test Methods for Determining the Effects of High Altitude on Packaging Systems by Vacuum Method Request a Quote Standard Summary High-altitude transport can significantly stress packaging systems. Whether you\u2019re in food, pharmaceuticals, or electronics, understanding how packaging behaves under reduced pressure is crucial for preventing product damage. ASTM D6653, Standard Test Methods for&hellip;","_links":{"self":[{"href":"https:\/\/www.leakagetester.com\/nl\/wp-json\/wp\/v2\/pages\/4039","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.leakagetester.com\/nl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.leakagetester.com\/nl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/nl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/nl\/wp-json\/wp\/v2\/comments?post=4039"}],"version-history":[{"count":0,"href":"https:\/\/www.leakagetester.com\/nl\/wp-json\/wp\/v2\/pages\/4039\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/nl\/wp-json\/wp\/v2\/pages\/2112"}],"wp:attachment":[{"href":"https:\/\/www.leakagetester.com\/nl\/wp-json\/wp\/v2\/media?parent=4039"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}