{"id":4110,"date":"2025-05-26T17:13:43","date_gmt":"2025-05-26T09:13:43","guid":{"rendered":"https:\/\/www.leakagetester.com\/?page_id=4110"},"modified":"2025-05-27T08:28:34","modified_gmt":"2025-05-27T00:28:34","slug":"iso-11040-4","status":"publish","type":"page","link":"https:\/\/www.leakagetester.com\/pl\/standards\/iso-11040-4\/","title":{"rendered":"ISO 11040-4"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"4110\" class=\"elementor elementor-4110\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4987d4e6 e-flex e-con-boxed e-con e-parent\" data-id=\"4987d4e6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7b47303e elementor-widget elementor-widget-text-editor\" data-id=\"7b47303e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b290316 e-con-full e-flex e-con e-parent\" data-id=\"b290316\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-5c5c9cd e-con-full e-flex e-con e-child\" data-id=\"5c5c9cd\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0192e7d elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"0192e7d\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dad80d0 e-con-full e-flex e-con e-child\" data-id=\"dad80d0\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3d5573c elementor-widget elementor-widget-heading\" data-id=\"3d5573c\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h5 class=\"elementor-heading-title elementor-size-default\">Strzykawki wst\u0119pnie nape\u0142nione<br>Cz\u0119\u015b\u0107 4: Szklane beczki do wstrzykiwaczy i sterylizowane podstrzykawki gotowe do nape\u0142niania<\/h5>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-14bfcde elementor-tablet-align-center elementor-mobile-align-center elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-button\" data-id=\"14bfcde\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:200}\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/pl\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Popro\u015b o wycen\u0119<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7db034b e-flex e-con-boxed e-con e-parent\" data-id=\"7db034b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-0b99b3c e-con-full e-flex e-con e-child\" data-id=\"0b99b3c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dee3d55 elementor-widget elementor-widget-heading\" data-id=\"dee3d55\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Podsumowanie standardowe<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-070771a elementor-widget elementor-widget-text-editor\" data-id=\"070771a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1249\" data-end=\"1545\">Test szczelno\u015bci strzykawki ma na celu sprawdzenie <strong data-start=\"1290\" data-end=\"1346\">odporno\u015b\u0107 system\u00f3w zamykania strzykawek na wycieki cieczy<\/strong> w okre\u015blonych warunkach ci\u015bnienia. Wed\u0142ug <em data-start=\"1395\" data-end=\"1420\">Za\u0142\u0105cznik G2 do normy ISO 11040-4<\/em>, Test symuluje wewn\u0119trzne nadci\u015bnienie (typowo 110 kPa), kt\u00f3rego strzykawki mog\u0105 do\u015bwiadcza\u0107 podczas nape\u0142niania lub transportu.<\/p>\n<p data-start=\"1249\" data-end=\"1545\">Ten test ocenia zar\u00f3wno <strong data-start=\"1572\" data-end=\"1590\">os\u0142ony igie\u0142<\/strong> I <strong data-start=\"1595\" data-end=\"1607\">nak\u0142adki na ko\u0144c\u00f3wki<\/strong>, Dzi\u0119ki temu zamkni\u0119cia pozostaj\u0105 bezpieczne i nie przeciekaj\u0105 pod wp\u0142ywem napr\u0119\u017ce\u0144.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5e86730 e-con-full e-flex e-con e-child\" data-id=\"5e86730\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ae0f79e elementor-widget elementor-widget-image\" data-id=\"ae0f79e\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"200\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp\" class=\"attachment-medium size-medium wp-image-4116\" alt=\"ISO 11040-4\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp 600w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4-18x6.webp 18w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b86c929 elementor-widget elementor-widget-text-editor\" data-id=\"b86c929\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Taka ocena ma kluczowe znaczenie dla kontroli jako\u015bci farmaceutycznej, zapobiegania zanieczyszczeniom i zapewnienia dok\u0142adno\u015bci dawkowania.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5a6238d e-flex e-con-boxed e-con e-parent\" data-id=\"5a6238d\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-84ad92e elementor-widget elementor-widget-heading\" data-id=\"84ad92e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Metoda badania wycieku cieczy z systemu zamykania strzykawki<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b15d017 elementor-widget elementor-widget-text-editor\" data-id=\"b15d017\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1859\" data-end=\"1908\"><strong data-start=\"1859\" data-end=\"1908\">Kluczowe etapy testu (zgodnie z ISO 11040-4 za\u0142\u0105cznik G2):<\/strong><\/p>\n<ul>\n<li data-start=\"1912\" data-end=\"2038\"><strong data-start=\"1912\" data-end=\"1935\">Przygotowanie pr\u00f3bki:<\/strong> U\u017cywa\u0107 wysterylizowanych, zmontowanych strzykawek gotowych do nape\u0142nienia. Nale\u017cy unika\u0107 naruszania zamkni\u0119cia przed testem.<\/li>\n<li data-start=\"2041\" data-end=\"2125\"><strong data-start=\"2041\" data-end=\"2060\">Okres oczekiwania:<\/strong> Odczekaj co najmniej 12 godzin mi\u0119dzy ustawieniem zamkni\u0119cia a testowaniem.<\/li>\n<li data-start=\"2128\" data-end=\"2245\"><strong data-start=\"2128\" data-end=\"2140\">Wype\u0142nienie:<\/strong> Nape\u0142ni\u0107 strzykawk\u0119 wod\u0105 destylowan\u0105 lub wod\u0105 o r\u00f3wnowa\u017cnej czysto\u015bci do 1\/3-2\/3 jej nominalnej obj\u0119to\u015bci.<\/li>\n<li data-start=\"2248\" data-end=\"2399\"><strong data-start=\"2248\" data-end=\"2267\">Ci\u015bnienie:<\/strong> Zastosuj <strong data-start=\"2274\" data-end=\"2285\">110 kPa<\/strong> ci\u015bnienie za pomoc\u0105 spr\u0119\u017conego powietrza lub <strong data-start=\"2321\" data-end=\"2374\">uniwersalna maszyna do pr\u00f3b rozci\u0105gania i \u015bciskania<\/strong>. Przytrzymaj dla <strong data-start=\"2385\" data-end=\"2398\">5 sekund<\/strong>.<\/li>\n<li data-start=\"2402\" data-end=\"2537\"><strong data-start=\"2402\" data-end=\"2417\">Monitorowanie:<\/strong> Podczas testu i po jego zako\u0144czeniu nale\u017cy obserwowa\u0107 wyciek p\u0142ynu. Wyciek pojawia si\u0119 w postaci widocznych kropelek na zewn\u0119trznej powierzchni zamkni\u0119cia.<\/li>\n<li data-start=\"2540\" data-end=\"2654\"><strong data-start=\"2540\" data-end=\"2558\">Kryteria zaliczenia:<\/strong> \u017badne kropelki nie powinny by\u0107 widoczne, a zamkni\u0119cie (nasadka ko\u0144c\u00f3wki lub os\u0142ona ig\u0142y) musi pozosta\u0107 na swoim miejscu.<\/li>\n<\/ul>\n<blockquote data-start=\"2656\" data-end=\"2793\">\n<p data-start=\"2658\" data-end=\"2793\">Testy s\u0105 wa\u017cne zar\u00f3wno dla beczek strzykawek, jak i sterylnych podzespo\u0142\u00f3w. Kontrola wzrokowa jest niezb\u0119dna do okre\u015blenia wynik\u00f3w pozytywnych\/negatywnych.<\/p>\n<\/blockquote>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e2cd145 e-flex e-con-boxed e-con e-parent\" data-id=\"e2cd145\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-384e6ec elementor-widget elementor-widget-heading\" data-id=\"384e6ec\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Niezb\u0119dny sprz\u0119t do testowania szczelno\u015bci strzykawek<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4cd2af2 elementor-widget elementor-widget-text-editor\" data-id=\"4cd2af2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2850\" data-end=\"2893\">Konfiguracja sprz\u0119tu do tego testu obejmuje:<\/p>\n<ul>\n<li data-start=\"2897\" data-end=\"2985\"><strong data-start=\"2897\" data-end=\"2941\">Uniwersalny tester rozci\u0105gania i \u015bciskania<\/strong> Lub <strong data-start=\"2945\" data-end=\"2985\">system spr\u0119\u017conego powietrza<\/strong><\/li>\n<li data-start=\"2988\" data-end=\"3038\"><strong data-start=\"2988\" data-end=\"3006\">Uchwyt strzykawki<\/strong> z bezpiecznym mechanizmem uszczelniaj\u0105cym<\/li>\n<li data-start=\"3041\" data-end=\"3116\"><strong data-start=\"3041\" data-end=\"3071\">Manometr lub oprogramowanie<\/strong> zdolny do osi\u0105gni\u0119cia i utrzymania ci\u015bnienia 110 kPa<\/li>\n<li data-start=\"3119\" data-end=\"3208\"><strong data-start=\"3119\" data-end=\"3165\">System akwizycji danych o wysokiej cz\u0119stotliwo\u015bci pr\u00f3bkowania<\/strong> (zalecane 500 Hz dla pomiar\u00f3w szczytowych)<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4bdb15f e-flex e-con-boxed e-con e-parent\" data-id=\"4bdb15f\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f031e68 elementor-widget elementor-widget-heading\" data-id=\"f031e68\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Rozwi\u0105zania Cell Instruments:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9831b44 elementor-widget elementor-widget-text-editor\" data-id=\"9831b44\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3210\" data-end=\"3472\">Przeprowadzanie test\u00f3w szczelno\u015bci strzykawek zgodnie z norm\u0105 ISO 11040-4, <strong data-start=\"3307\" data-end=\"3373\">Cell Instruments oferuje konfigurowalne platformy do testowania strzykawek<\/strong>, Kompatybilny zar\u00f3wno ze spr\u0119\u017conym powietrzem, jak i mechanicznymi metodami aplikacji si\u0142y. Nasze systemy zapewniaj\u0105:<\/p>\n<ul>\n<li data-start=\"3476\" data-end=\"3517\"><strong data-start=\"3476\" data-end=\"3517\">Dok\u0142adna kontrola ci\u015bnienia wewn\u0119trznego<\/strong><\/li>\n<li data-start=\"3520\" data-end=\"3560\"><strong data-start=\"3520\" data-end=\"3560\">Pr\u00f3bkowanie wysokiej cz\u0119stotliwo\u015bci do 500 Hz<\/strong><\/li>\n<li data-start=\"3563\" data-end=\"3610\"><strong data-start=\"3563\" data-end=\"3610\">Pe\u0142na zgodno\u015b\u0107 z procedurami testowymi ISO<\/strong><\/li>\n<li data-start=\"3613\" data-end=\"3675\"><strong data-start=\"3613\" data-end=\"3649\">Zautomatyzowane funkcje dokumentacji<\/strong> dla raportowania gotowego do audytu<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d0f3e8d e-flex e-con-boxed e-con e-parent\" data-id=\"d0f3e8d\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-bdde50c e-con-full e-flex e-con e-child\" data-id=\"bdde50c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4b4c297 elementor-widget elementor-widget-heading\" data-id=\"4b4c297\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Rozwi\u0105zania Cell Instruments:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f28aead elementor-widget elementor-widget-text-editor\" data-id=\"f28aead\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3210\" data-end=\"3472\">Przeprowadzanie test\u00f3w szczelno\u015bci strzykawek zgodnie z norm\u0105 ISO 11040-4, <strong data-start=\"3307\" data-end=\"3373\">Cell Instruments oferuje konfigurowalne platformy do testowania strzykawek<\/strong>, Kompatybilny zar\u00f3wno ze spr\u0119\u017conym powietrzem, jak i mechanicznymi metodami aplikacji si\u0142y. Nasze systemy zapewniaj\u0105:<\/p>\n<ul>\n<li data-start=\"3476\" data-end=\"3517\"><strong data-start=\"3476\" data-end=\"3517\">Dok\u0142adna kontrola ci\u015bnienia wewn\u0119trznego<\/strong><\/li>\n<li data-start=\"3520\" data-end=\"3560\"><strong data-start=\"3520\" data-end=\"3560\">Pr\u00f3bkowanie wysokiej cz\u0119stotliwo\u015bci do 500 Hz<\/strong><\/li>\n<li data-start=\"3563\" data-end=\"3610\"><strong data-start=\"3563\" data-end=\"3610\">Pe\u0142na zgodno\u015b\u0107 z procedurami testowymi ISO<\/strong><\/li>\n<li data-start=\"3613\" data-end=\"3675\"><strong data-start=\"3613\" data-end=\"3649\">Zautomatyzowane funkcje dokumentacji<\/strong> dla raportowania gotowego do audytu<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-513146a e-flex e-con-boxed e-con e-parent\" data-id=\"513146a\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-f93229d e-con-full e-flex e-con e-child\" data-id=\"f93229d\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ad6986d elementor-widget elementor-widget-heading\" data-id=\"ad6986d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Rejestracja i dokumentacja danych<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b242490 elementor-widget elementor-widget-text-editor\" data-id=\"b242490\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3720\" data-end=\"3781\">Wed\u0142ug <em data-start=\"3733\" data-end=\"3743\">Za\u0142\u0105cznik G2<\/em>, Kompletny raport z testu musi zawiera\u0107<\/p>\n<ul>\n<li data-start=\"3785\" data-end=\"3835\"><strong data-start=\"3785\" data-end=\"3805\">Zastosowane ci\u015bnienie<\/strong> (kPa) lub si\u0142a r\u00f3wnowa\u017cna (N)<\/li>\n<li data-start=\"3838\" data-end=\"3867\"><strong data-start=\"3838\" data-end=\"3867\">Liczba przetestowanych strzykawek<\/strong><\/li>\n<li data-start=\"3870\" data-end=\"3905\"><strong data-start=\"3870\" data-end=\"3905\">Liczba zaliczonych\/niezaliczonych pr\u00f3bek<\/strong><\/li>\n<li data-start=\"3908\" data-end=\"3945\"><strong data-start=\"3908\" data-end=\"3945\">Obserwacje wizualne lub odchylenia<\/strong><\/li>\n<li data-start=\"3946\" data-end=\"4011\">\n<p data-start=\"3948\" data-end=\"4011\"><strong data-start=\"3948\" data-end=\"3984\">Identyfikowalno\u015b\u0107 parametr\u00f3w konfiguracji<\/strong> (r\u0119cznie lub za pomoc\u0105 oprogramowania)<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4013\" data-end=\"4193\">Dokumentuj\u0105c warunki i wyniki test\u00f3w, producenci wykazuj\u0105 zgodno\u015b\u0107 z norm\u0105 ISO 11040-4 i zapewniaj\u0105 <strong data-start=\"4123\" data-end=\"4150\">identyfikowalno\u015b\u0107 regulacyjna<\/strong>-niezb\u0119dny dla farmaceutycznych system\u00f3w jako\u015bci.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c13f4f1 e-con-full e-flex e-con e-child\" data-id=\"c13f4f1\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fa7bb58 elementor-widget elementor-widget-heading\" data-id=\"fa7bb58\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Obliczanie si\u0142y wewn\u0119trznej<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e89f57a elementor-widget elementor-widget-text-editor\" data-id=\"e89f57a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4232\" data-end=\"4417\">W przypadku urz\u0105dze\u0144 wykorzystuj\u0105cych si\u0142\u0119 mechaniczn\u0105 zamiast ci\u015bnienia powietrza, wymagana jest <strong data-start=\"4311\" data-end=\"4324\">si\u0142a (F)<\/strong> do symulacji ci\u015bnienia wewn\u0119trznego 110 kPa mo\u017cna obliczy\u0107 przy u\u017cyciu wzor\u00f3w z normy ISO 11040-4:<\/p>\n<blockquote data-start=\"4419\" data-end=\"4459\">\n<p data-start=\"4421\" data-end=\"4459\"><strong data-start=\"4421\" data-end=\"4448\">F = p \u00d7 \u03c0\/4 \u00d7 d\u00b2 \u00d7 10-\u00b3<\/strong><br data-start=\"4448\" data-end=\"4451\" \/>Gdzie:<\/p>\n<\/blockquote>\n<ul>\n<li data-start=\"4462\" data-end=\"4488\"><strong data-start=\"4462\" data-end=\"4467\">F<\/strong> = si\u0142a w niutonach<\/li>\n<li data-start=\"4491\" data-end=\"4519\"><strong data-start=\"4491\" data-end=\"4496\">p<\/strong> = ci\u015bnienie (110 kPa)<\/li>\n<li data-start=\"4522\" data-end=\"4562\"><strong data-start=\"4522\" data-end=\"4527\">d<\/strong> = Wewn\u0119trzna \u015brednica strzykawki (mm)<\/li>\n<\/ul>\n<p data-start=\"4564\" data-end=\"4647\">To obliczenie pomaga zapewni\u0107 <strong data-start=\"4594\" data-end=\"4623\">dok\u0142adna replikacja testu<\/strong> i kalibracja urz\u0105dzenia.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 11040-4 Prefilled syringesPart 4: Glass barrels for injectables and sterilized subassembled syringes ready for filling Request a Quote Standard Summary The syringe leak test aims to verify the liquid leakage resistance of syringe closure systems under defined pressure conditions. According to Annex G2 of ISO 11040-4, the test simulates internal overpressure (typically 110 kPa) [&#8230;]","protected":false},"author":2,"featured_media":0,"parent":2112,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-4110","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ISO 11040-4 Syringe Leak Test - Closure System Liquid Leakage<\/title>\n<meta name=\"description\" content=\"Syringe leak test per ISO 11040-4 Annex G2 to ensure closure integrity. Discover the test method, apparatus.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.leakagetester.com\/pl\/standards\/iso-11040-4\/\" \/>\n<meta property=\"og:locale\" content=\"pl_PL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ISO 11040-4 Syringe Leak Test - Closure System Liquid Leakage\" \/>\n<meta property=\"og:description\" content=\"Syringe leak test per ISO 11040-4 Annex G2 to ensure closure integrity. Discover the test method, apparatus.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.leakagetester.com\/pl\/standards\/iso-11040-4\/\" \/>\n<meta property=\"og:site_name\" content=\"Leakage Tester\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/cellinstruments\/\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-27T00:28:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Szacowany czas czytania\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minuty\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/\",\"url\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/\",\"name\":\"ISO 11040-4 Syringe Leak Test - Closure System Liquid Leakage\",\"isPartOf\":{\"@id\":\"https:\/\/www.leakagetester.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp\",\"datePublished\":\"2025-05-26T09:13:43+00:00\",\"dateModified\":\"2025-05-27T00:28:34+00:00\",\"description\":\"Syringe leak test per ISO 11040-4 Annex G2 to ensure closure integrity. Discover the test method, apparatus.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#breadcrumb\"},\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#primaryimage\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.leakagetester.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Standards\",\"item\":\"https:\/\/www.leakagetester.com\/standards\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ISO 11040-4\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.leakagetester.com\/#website\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"name\":\"Leakage Testing Solutions\",\"description\":\"CELL INSTRUMENTS CO., LTD.\",\"publisher\":{\"@id\":\"https:\/\/www.leakagetester.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.leakagetester.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pl-PL\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.leakagetester.com\/#organization\",\"name\":\"Cell Instruments Co., Ltd.\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"width\":1269,\"height\":342,\"caption\":\"Cell Instruments Co., Ltd.\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/cellinstruments\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ISO 11040-4 Test szczelno\u015bci strzykawki - wyciek cieczy z systemu zamykania","description":"Test szczelno\u015bci strzykawki zgodnie z norm\u0105 ISO 11040-4 za\u0142\u0105cznik G2 w celu zapewnienia integralno\u015bci zamkni\u0119cia. Odkryj metod\u0119 testow\u0105, aparatur\u0119.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.leakagetester.com\/pl\/standards\/iso-11040-4\/","og_locale":"pl_PL","og_type":"article","og_title":"ISO 11040-4 Syringe Leak Test - Closure System Liquid Leakage","og_description":"Syringe leak test per ISO 11040-4 Annex G2 to ensure closure integrity. Discover the test method, apparatus.","og_url":"https:\/\/www.leakagetester.com\/pl\/standards\/iso-11040-4\/","og_site_name":"Leakage Tester","article_publisher":"https:\/\/www.facebook.com\/cellinstruments\/","article_modified_time":"2025-05-27T00:28:34+00:00","og_image":[{"width":600,"height":200,"url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Szacowany czas czytania":"3 minuty"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/","url":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/","name":"ISO 11040-4 Test szczelno\u015bci strzykawki - wyciek cieczy z systemu zamykania","isPartOf":{"@id":"https:\/\/www.leakagetester.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#primaryimage"},"image":{"@id":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#primaryimage"},"thumbnailUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp","datePublished":"2025-05-26T09:13:43+00:00","dateModified":"2025-05-27T00:28:34+00:00","description":"Test szczelno\u015bci strzykawki zgodnie z norm\u0105 ISO 11040-4 za\u0142\u0105cznik G2 w celu zapewnienia integralno\u015bci zamkni\u0119cia. Odkryj metod\u0119 testow\u0105, aparatur\u0119.","breadcrumb":{"@id":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#breadcrumb"},"inLanguage":"pl-PL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/"]}]},{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#primaryimage","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.leakagetester.com\/standards\/iso-11040-4\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.leakagetester.com\/"},{"@type":"ListItem","position":2,"name":"Standards","item":"https:\/\/www.leakagetester.com\/standards\/"},{"@type":"ListItem","position":3,"name":"ISO 11040-4"}]},{"@type":"WebSite","@id":"https:\/\/www.leakagetester.com\/#website","url":"https:\/\/www.leakagetester.com\/","name":"Rozwi\u0105zania do testowania szczelno\u015bci","description":"CELL INSTRUMENTS CO., LTD.","publisher":{"@id":"https:\/\/www.leakagetester.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.leakagetester.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pl-PL"},{"@type":"Organization","@id":"https:\/\/www.leakagetester.com\/#organization","name":"Cell Instruments Co., Ltd.","url":"https:\/\/www.leakagetester.com\/","logo":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","width":1269,"height":342,"caption":"Cell Instruments Co., Ltd."},"image":{"@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/cellinstruments\/"]}]}},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"leakagetester","author_link":"https:\/\/www.leakagetester.com\/pl\/author\/leakagetester\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 11040-4 Prefilled syringesPart 4: Glass barrels for injectables and sterilized subassembled syringes ready for filling Request a Quote Standard Summary The syringe leak test aims to verify the liquid leakage resistance of syringe closure systems under defined pressure conditions. According to Annex G2 of ISO 11040-4, the test simulates internal overpressure (typically 110 kPa)&hellip;","_links":{"self":[{"href":"https:\/\/www.leakagetester.com\/pl\/wp-json\/wp\/v2\/pages\/4110","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.leakagetester.com\/pl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.leakagetester.com\/pl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/pl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/pl\/wp-json\/wp\/v2\/comments?post=4110"}],"version-history":[{"count":0,"href":"https:\/\/www.leakagetester.com\/pl\/wp-json\/wp\/v2\/pages\/4110\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/pl\/wp-json\/wp\/v2\/pages\/2112"}],"wp:attachment":[{"href":"https:\/\/www.leakagetester.com\/pl\/wp-json\/wp\/v2\/media?parent=4110"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}