{"id":4129,"date":"2025-06-04T11:01:02","date_gmt":"2025-06-04T03:01:02","guid":{"rendered":"https:\/\/www.leakagetester.com\/?p=4129"},"modified":"2025-11-14T11:19:51","modified_gmt":"2025-11-14T03:19:51","slug":"syringe-leak-tester-liquid-leakage-test-method","status":"publish","type":"post","link":"https:\/\/www.leakagetester.com\/sq\/syringe-leak-tester-liquid-leakage-test-method\/","title":{"rendered":"SPPT-01 Testues i hermetizimit me presion pozitiv me shiring\u00eb"},"content":{"rendered":"<div class=\"wp-block-uagb-container uagb-block-a8b8c7e6 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-cfed79de\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-uagb-slider uagb-block-e6e13507 uagb-slider-container\"><div class=\"uagb-slides uagb-swiper\"><div class=\"swiper-wrapper\">\n<div class=\"wp-block-uagb-slider-child uagb-slider-child-wrap swiper-slide uagb-block-9ccd59aa\"><div class=\"swiper-content\">\n<div class=\"wp-block-uagb-container uagb-block-55bd0fea\">\n<div class=\"wp-block-uagb-image uagb-block-bdef5d91 wp-block-uagb-image--layout-overlay wp-block-uagb-image--effect-zoomin wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img loading=\"lazy\" decoding=\"async\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-01-1.webp ,https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-01-1.webp 780w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-01-1.webp 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-01-1.webp\" alt=\"\" class=\"uag-image-4134\" width=\"800\" height=\"800\" title=\"\" role=\"presentation\"\/><div class=\"wp-block-uagb-image--layout-overlay__color-wrapper\"><\/div><div class=\"wp-block-uagb-image--layout-overlay__inner center-center\"><\/div><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n<\/div><\/div><div class=\"swiper-pagination\"><\/div><div class=\"swiper-button-prev\"><\/div><div class=\"swiper-button-next\"><\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-ea2274bd\"><div class=\"wp-block-post-excerpt\"><p class=\"wp-block-post-excerpt__excerpt\">Testuesi i rrjedhjeve t\u00eb shiringave \u00ebsht\u00eb nj\u00eb mjet thelb\u00ebsor p\u00ebr kontrollin e cil\u00ebsis\u00eb n\u00eb prodhimin e pajisjeve mjek\u00ebsore. Sigurimi q\u00eb shiringat t\u00eb mos ken\u00eb rrjedhje \u00ebsht\u00eb jetik p\u00ebr sigurin\u00eb e pacientit dhe besueshm\u00ebrin\u00eb e produktit. Ky artikull analizon procesin e testimit t\u00eb rrjedhjes s\u00eb l\u00ebngut dhe thekson r\u00ebnd\u00ebsin\u00eb e standardeve si ISO 7886-1 dhe ISO 11040-4 p\u00ebr t'ju ndihmuar t\u00eb kuptoni se si t\u00eb vler\u00ebsoni n\u00eb m\u00ebnyr\u00eb efektive performanc\u00ebn e shiringave. <\/p><\/div>\n\n\n<div class=\"wp-block-uagb-buttons uagb-buttons__outer-wrap uagb-btn__default-btn uagb-btn-tablet__default-btn uagb-btn-mobile__default-btn uagb-block-eb1e00e0\"><div class=\"uagb-buttons__wrap uagb-buttons-layout-wrap\">\n<div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-bfc5e3d0 wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/SPPT-01-Syringe-Positive-Pressure-Tightness-Tester.pdf\" rel=\"follow noopener\" target=\"_blank\" role=\"button\"><span class=\"uagb-button__icon uagb-button__icon-position-before\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 384 512\" aria-hidden=\"true\" focussable=\"false\"><path d=\"M88 304H80V256H88C101.3 256 112 266.7 112 280C112 293.3 101.3 304 88 304zM192 256H200C208.8 256 216 263.2 216 272V336C216 344.8 208.8 352 200 352H192V256zM224 0V128C224 145.7 238.3 160 256 160H384V448C384 483.3 355.3 512 320 512H64C28.65 512 0 483.3 0 448V64C0 28.65 28.65 0 64 0H224zM64 224C55.16 224 48 231.2 48 240V368C48 376.8 55.16 384 64 384C72.84 384 80 376.8 80 368V336H88C118.9 336 144 310.9 144 280C144 249.1 118.9 224 88 224H64zM160 368C160 376.8 167.2 384 176 384H200C226.5 384 248 362.5 248 336V272C248 245.5 226.5 224 200 224H176C167.2 224 160 231.2 160 240V368zM288 224C279.2 224 272 231.2 272 240V368C272 376.8 279.2 384 288 384C296.8 384 304 376.8 304 368V320H336C344.8 320 352 312.8 352 304C352 295.2 344.8 288 336 288H304V256H336C344.8 256 352 248.8 352 240C352 231.2 344.8 224 336 224H288zM256 0L384 128H256V0z\"><\/path><\/svg><\/span><div class=\"uagb-button__link\">Shkarko Katalogun<\/div><\/a><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-buttons-child uagb-buttons__outer-wrap uagb-block-7665642e wp-block-button\"><div class=\"uagb-button__wrapper\"><a class=\"uagb-buttons-repeater wp-block-button__link\" aria-label=\"\" href=\"\/sq\/contact\/\" rel=\"follow noopener\" target=\"_self\" role=\"button\"><div class=\"uagb-button__link\">K\u00ebrkoni nj\u00eb ofert\u00eb<\/div><span class=\"uagb-button__icon uagb-button__icon-position-after\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 448 512\" aria-hidden=\"true\" focussable=\"false\"><path d=\"M438.6 278.6l-160 160C272.4 444.9 264.2 448 256 448s-16.38-3.125-22.62-9.375c-12.5-12.5-12.5-32.75 0-45.25L338.8 288H32C14.33 288 .0016 273.7 .0016 256S14.33 224 32 224h306.8l-105.4-105.4c-12.5-12.5-12.5-32.75 0-45.25s32.75-12.5 45.25 0l160 160C451.1 245.9 451.1 266.1 438.6 278.6z\"><\/path><\/svg><\/span><\/a><\/div><\/div>\n<\/div><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-60899116 wp-block-uagb-separator--text\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><div class=\"wp-block-uagb-separator-element\"><h2 class=\"uagb-html-tag\">Hyrje<\/h2><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-group alignfull is-content-justification-center is-layout-constrained wp-container-core-group-is-layout-1764ef02 wp-block-group-is-layout-constrained\" style=\"margin-top:0;margin-bottom:0;padding-top:calc( 0.5 * var(u002du002dwpu002du002dstyleu002du002drootu002du002dpadding-right, var(u002du002dwpu002du002dcustomu002du002dgapu002du002dhorizontal)));padding-right:var(u002du002dwpu002du002dstyleu002du002drootu002du002dpadding-right, var(u002du002dwpu002du002dcustomu002du002dgapu002du002dhorizontal));padding-bottom:calc( 0.5 * var(u002du002dwpu002du002dstyleu002du002drootu002du002dpadding-right, var(u002du002dwpu002du002dcustomu002du002dgapu002du002dhorizontal)));padding-left:var(u002du002dwpu002du002dstyleu002du002drootu002du002dpadding-left, var(u002du002dwpu002du002dcustomu002du002dgapu002du002dhorizontal))\">\n<div style=\"height:calc( 0.25 * var(u002du002dwpu002du002dstyleu002du002drootu002du002dpadding-right, var(u002du002dwpu002du002dcustomu002du002dgapu002du002dhorizontal)))\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 35%\"><div class=\"wp-block-media-text__content\">\n<p class=\"has-text-align-left\"><strong>Testuesi i rrjedhjes s\u00eb shiring\u00ebs<\/strong> \u00cbsht\u00eb projektuar p\u00ebr t\u00eb vler\u00ebsuar integritetin e komponent\u00ebve t\u00eb shiring\u00ebs duke matur rezistenc\u00ebn e tyre ndaj rrjedhjes s\u00eb l\u00ebngut. Ky proces testimi \u00ebsht\u00eb thelb\u00ebsor p\u00ebr parandalimin e kontaminimit, ruajtjen e sterilitetit dhe p\u00ebrputhshm\u00ebrin\u00eb me standardet rregullatore.<\/p>\n\n\n\n<p>Testuesi zakonisht p\u00ebrb\u00ebhet nga:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Nj\u00eb pajisje vulos\u00ebse p\u00ebr nozul\u00ebn e shiring\u00ebs.<\/li>\n\n\n\n<li>Nj\u00eb mekaniz\u00ebm p\u00ebr t\u00eb aplikuar <strong>anash<\/strong> dhe <strong>forcat aksiale<\/strong>.<\/li>\n\n\n\n<li>Sistemet e gjenerimit t\u00eb presionit.<\/li>\n\n\n\n<li>Nj\u00eb zon\u00eb p\u00ebr inspektim vizual p\u00ebr t\u00eb zbuluar rrjedhje.<\/li>\n<\/ul>\n\n\n\n<p class=\"has-text-align-left\">Duke p\u00ebrdorur instrumentacion t\u00eb sakt\u00eb, testuesi i rrjedhjeve t\u00eb shiringave ndihmon n\u00eb sigurimin q\u00eb shiringat t\u00eb p\u00ebrmbushin k\u00ebrkesat e rrepta t\u00eb cil\u00ebsis\u00eb.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img fetchpriority=\"high\" decoding=\"async\" width=\"364\" height=\"800\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-364x800.webp\" alt=\"\" class=\"wp-image-4132 size-full\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-364x800.webp 364w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-182x400.webp 182w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-768x1690.webp 768w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-698x1536.webp 698w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-931x2048.webp 931w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-5x12.webp 5w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-scaled.webp 1164w\" sizes=\"(max-width: 364px) 100vw, 364px\" \/><\/figure><\/div>\n\n\n\n<div style=\"height:0px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Aplikimet e testuesve t\u00eb rrjedhjes s\u00eb shiringave<\/strong><\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">T\u00eb <strong>Testuesi i rrjedhjes s\u00eb shiring\u00ebs<\/strong> p\u00ebrdoret gjer\u00ebsisht n\u00eb:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Prodhimi i pajisjeve mjek\u00ebsore<\/strong> p\u00ebr t\u00eb siguruar p\u00ebrputhshm\u00ebrin\u00eb me standardet globale.<\/li>\n\n\n\n<li><strong>Proceset e mbushjes farmaceutike<\/strong> p\u00ebr t\u00eb garantuar sigurin\u00eb e produktit gjat\u00eb magazinimit dhe transportit.<\/li>\n\n\n\n<li><strong>Laborator\u00ebt e kontrollit t\u00eb cil\u00ebsis\u00eb<\/strong> p\u00ebr testimin rutin\u00eb t\u00eb serive t\u00eb shiringave.<\/li>\n\n\n\n<li><strong>K\u00ebrkim dhe zhvillim<\/strong> p\u00ebr t\u00eb verifikuar dizajne t\u00eb reja t\u00eb shiringave.<\/li>\n<\/ul>\n\n\n\n<p>N\u00eb <strong>Instrumentet e qelizave<\/strong>, ne specializohemi n\u00eb ofrimin e zgjidhjeve t\u00eb avancuara t\u00eb testimit, duke p\u00ebrfshir\u00eb ato t\u00eb personalizueshme <strong>Testues t\u00eb rrjedhjes s\u00eb shiringave<\/strong> q\u00eb plot\u00ebsojn\u00eb nevoja specifike n\u00eb industrin\u00eb mjek\u00ebsore, farmaceutike dhe industrit\u00eb e lidhura.<\/p>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-5e8e0028 wp-block-uagb-separator--text\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><div class=\"wp-block-uagb-separator-element\"><h2 class=\"uagb-html-tag\">Standard<\/h2><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-e9d70f96 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-f3877285\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-a15c6943 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/www.leakagetester.com\/sq\/standards\/iso-7886-1\/\" target=\"_blank\" rel=\"noreferrer noopener\"><img loading=\"lazy\" decoding=\"async\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/03\/ISO-7886-1.webp ,https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/03\/ISO-7886-1.webp 780w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/03\/ISO-7886-1.webp 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/03\/ISO-7886-1.webp\" alt=\"\" class=\"uag-image-3984\" width=\"318\" height=\"106\" title=\"ISO 7886-1\" role=\"img\"\/><\/a><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">P\u00ebrputhshm\u00ebria me ISO 7886-1<\/h3>\n\n\n\n<p><strong>ISO 7886-1<\/strong> \u00ebsht\u00eb nj\u00eb standard i njohur globalisht q\u00eb p\u00ebrcakton k\u00ebrkesat e dizajnit dhe t\u00eb performanc\u00ebs p\u00ebr shiringat hipodermike sterile p\u00ebr p\u00ebrdorim t\u00eb vet\u00ebm. <strong>Shtojca D<\/strong> e ISO 7886-1 ofron metod\u00ebn normative t\u00eb testimit p\u00ebr <strong>rrjedhje l\u00ebngu<\/strong> n\u00eb tapin e pistonit t\u00eb shiring\u00ebs n\u00ebn kompresion.<\/p>\n\n\n\n<p>Kjo metod\u00eb testimi simulon n\u00eb m\u00ebnyr\u00eb efektive streset e bot\u00ebs reale mbi shiring\u00ebn, duke siguruar integritetin e produktit dhe p\u00ebrputhshm\u00ebrin\u00eb me <strong>ISO 7886-1<\/strong>.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-a0b0a0c1\">\n<h3 class=\"wp-block-heading\">K\u00ebrkesat kryesore nga ISO 7886-1 Shtojca D<\/h3>\n\n\n\n<p>T\u00eb <strong>Testi i rrjedhjes s\u00eb l\u00ebngut<\/strong> Siguron q\u00eb vul\u00eb e tapit t\u00eb pistonit t\u00eb rezistoj\u00eb presionit t\u00eb brendsh\u00ebm pa lejuar q\u00eb l\u00ebngu t\u00eb dal\u00eb. Ja nj\u00eb p\u00ebrmbledhje e shkurt\u00ebr e procedur\u00ebs s\u00eb testimit:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Mbushni shiring\u00ebn me uj\u00eb t\u00eb distiluar (temperatur\u00eb: 18 \u00b0C deri n\u00eb 28 \u00b0C) deri n\u00eb kapacitetin e saj nominal.<\/li>\n\n\n\n<li>Vulosni nozul\u00ebn e shiring\u00ebs.<\/li>\n\n\n\n<li>Aplikoni nj\u00eb <strong>forc\u00eb an\u00ebsore<\/strong> (0,25 N deri n\u00eb 3 N) n\u00eb nj\u00eb k\u00ebnd t\u00eb drejt\u00eb me pistonin. Kjo siguron devijimin maksimal nga pozicioni aksial.<\/li>\n\n\n\n<li>Aplikoni nj\u00eb <strong>forca aksiale<\/strong> p\u00ebr t\u00eb gjeneruar presione t\u00eb brendshme t\u00eb <strong>200 kPa<\/strong> ose <strong>300 kPa<\/strong>.<\/li>\n\n\n\n<li>Mbajeni k\u00ebt\u00eb presion p\u00ebr <strong>30 deri n\u00eb 35 sekonda<\/strong>.<\/li>\n\n\n\n<li>Inspektoni vizualisht shiring\u00ebn p\u00ebr ndonj\u00eb rrjedhje l\u00ebngu rreth bllokuesit t\u00eb pistonit.<\/li>\n<\/ul>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-788adb9b alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-a20a87a9\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-0224fa18 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><a class=\"\" href=\"https:\/\/www.leakagetester.com\/sq\/standards\/iso-11040-4\/\" target=\"_blank\" rel=\"noreferrer noopener\"><img loading=\"lazy\" decoding=\"async\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp ,https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp 780w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/05\/ISO-11040-4.webp\" alt=\"ISO 11040-4\" class=\"uag-image-4116\" width=\"318\" height=\"106\" title=\"ISO 11040-4\" role=\"img\"\/><\/a><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">P\u00ebrputhshm\u00ebria me ISO 11040-4<\/h3>\n\n\n\n<p>P\u00ebr <strong>shiringa t\u00eb parap\u00ebrgatitura<\/strong>, i <strong>ISO 11040-4<\/strong> standardi \u00ebsht\u00eb kritik. Konkretisht, <strong>Shtojca G.2<\/strong> adreson testin e rrjedhjes s\u00eb l\u00ebngut p\u00ebr sistemet e mbylljes s\u00eb shiringave, duke p\u00ebrfshir\u00eb <strong>kapak maja<\/strong> dhe <strong>mburoja e gjilp\u00ebr\u00ebs<\/strong>.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-1ea924b1\">\n<h3 class=\"wp-block-heading\">K\u00ebrkesat kryesore nga ISO 11040-4 Shtojca G2<\/h3>\n\n\n\n<p>Pikat kryesore t\u00eb <strong>Testi i rrjedhjes s\u00eb l\u00ebngut<\/strong> n\u00eb ISO 11040-4 p\u00ebrfshihen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Siringa mbushet me nj\u00eb reagens n\u00eb nj\u00eb sasi q\u00eb p\u00ebrb\u00ebn midis 1\/3 dhe 2\/3 t\u00eb v\u00ebllimit t\u00eb saj nominal.<\/li>\n\n\n\n<li>Nj\u00eb presion i <strong>110 kPa<\/strong> \u00ebsht\u00eb aplikuar p\u00ebr <strong>5 sekonda<\/strong> p\u00ebr t\u00eb simuluar skenar\u00eb t\u00eb mbinxhesimit gjat\u00eb mbushjes ose transportit.<\/li>\n\n\n\n<li>Forca e ushtruar llogaritet bazuar n\u00eb diametrin e brendsh\u00ebm t\u00eb trupit t\u00eb shiring\u00ebs, duke siguruar kushte testimi t\u00eb sakta dhe t\u00eb p\u00ebrs\u00ebritshme.<\/li>\n\n\n\n<li>Pas \u00e7lirimit t\u00eb presionit, shiringa inspektohet vizualisht p\u00ebr \u00e7do pik\u00eb ose komponent t\u00eb zhvendosur.<\/li>\n<\/ul>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-be50f835 wp-block-uagb-separator--text\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><div class=\"wp-block-uagb-separator-element\"><h2 class=\"uagb-html-tag\">Parimi i pun\u00ebs<\/h2><\/div><\/div><\/div>\n\n\n\n<p>Nj\u00eb testues rrjedhshm\u00ebrie p\u00ebr shiringa funksionon duke krijuar nj\u00eb vakum t\u00eb kontrolluar brenda shiring\u00ebs, nd\u00ebrsa monitoron stabilitetin e presionit. <strong>SLT-02 Testuesi i rrjedhjeve t\u00eb shiring\u00ebs<\/strong>, p\u00ebr shembull, p\u00ebrdor:<\/p>\n\n\n\n<div class=\"wp-block-uagb-icon-list uagb-block-9c066722\"><div class=\"uagb-icon-list__wrap\">\n<div class=\"wp-block-uagb-icon-list-child uagb-block-5ffb576f\"><span class=\"uagb-icon-list__source-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 512 512\"><path d=\"M256 0C114.6 0 0 114.6 0 256c0 141.4 114.6 256 256 256s256-114.6 256-256C512 114.6 397.4 0 256 0zM406.6 278.6l-103.1 103.1c-12.5 12.5-32.75 12.5-45.25 0s-12.5-32.75 0-45.25L306.8 288H128C110.3 288 96 273.7 96 256s14.31-32 32-32h178.8l-49.38-49.38c-12.5-12.5-12.5-32.75 0-45.25s32.75-12.5 45.25 0l103.1 103.1C414.6 241.3 416 251.1 416 256C416 260.9 414.6 270.7 406.6 278.6z\"><\/path><\/svg><\/span><span class=\"uagb-icon-list__label\">Lista e artikujve<\/span><\/div>\n\n\n\n<div class=\"wp-block-uagb-icon-list-child uagb-block-4b919c7d\"><span class=\"uagb-icon-list__source-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 512 512\"><path d=\"M256 0C114.6 0 0 114.6 0 256c0 141.4 114.6 256 256 256s256-114.6 256-256C512 114.6 397.4 0 256 0zM406.6 278.6l-103.1 103.1c-12.5 12.5-32.75 12.5-45.25 0s-12.5-32.75 0-45.25L306.8 288H128C110.3 288 96 273.7 96 256s14.31-32 32-32h178.8l-49.38-49.38c-12.5-12.5-12.5-32.75 0-45.25s32.75-12.5 45.25 0l103.1 103.1C414.6 241.3 416 251.1 416 256C416 260.9 414.6 270.7 406.6 278.6z\"><\/path><\/svg><\/span><span class=\"uagb-icon-list__label\">Lista e artikujve<\/span><\/div>\n\n\n\n<div class=\"wp-block-uagb-icon-list-child uagb-block-39ed9b88\"><span class=\"uagb-icon-list__source-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 512 512\"><path d=\"M256 0C114.6 0 0 114.6 0 256c0 141.4 114.6 256 256 256s256-114.6 256-256C512 114.6 397.4 0 256 0zM406.6 278.6l-103.1 103.1c-12.5 12.5-32.75 12.5-45.25 0s-12.5-32.75 0-45.25L306.8 288H128C110.3 288 96 273.7 96 256s14.31-32 32-32h178.8l-49.38-49.38c-12.5-12.5-12.5-32.75 0-45.25s32.75-12.5 45.25 0l103.1 103.1C414.6 241.3 416 251.1 416 256C416 260.9 414.6 270.7 406.6 278.6z\"><\/path><\/svg><\/span><span class=\"uagb-icon-list__label\">Lista e artikujve<\/span><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-809e5457 wp-block-uagb-separator--text\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><div class=\"wp-block-uagb-separator-element\"><h2 class=\"uagb-html-tag\">Specifikimet kryesore teknike<\/h2><\/div><\/div><\/div>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Qeliza ngarkese<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">200N (ose sipas nevoj\u00ebs)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong><strong>Testo shpejt\u00ebsin\u00eb<\/strong><\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">1~500mm\/min<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong><strong><strong>Sakt\u00ebsia<\/strong><\/strong><\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">0.01mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Fuqia<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">110~220V 50\/60Hz&nbsp;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div class=\"wp-block-uagb-separator uagb-block-c66e9afa wp-block-uagb-separator--text\"><div class=\"wp-block-uagb-separator__inner\" style=\"--my-background-image:\"><div class=\"wp-block-uagb-separator-element\"><h2 class=\"uagb-html-tag\">Karakteristikat teknike<\/h2><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-f504850c alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-f84137e0\">\n<div class=\"wp-block-uagb-info-box uagb-block-bf6b6bdf uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-icon-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 512 512\"><path d=\"M0 256C0 114.6 114.6 0 256 0C397.4 0 512 114.6 512 256C512 397.4 397.4 512 256 512C114.6 512 0 397.4 0 256zM371.8 211.8C382.7 200.9 382.7 183.1 371.8 172.2C360.9 161.3 343.1 161.3 332.2 172.2L224 280.4L179.8 236.2C168.9 225.3 151.1 225.3 140.2 236.2C129.3 247.1 129.3 264.9 140.2 275.8L204.2 339.8C215.1 350.7 232.9 350.7 243.8 339.8L371.8 211.8z\"><\/path><\/svg><\/div><div class=\"uagb-ifb-title-wrap\"><h3 class=\"uagb-ifb-title\"><strong><strong><strong>P\u00ebrputhshm\u00ebria<\/strong> me<\/strong><\/strong><\/h3><\/div><p class=\"uagb-ifb-desc\"><strong>ISO 7886-1<\/strong> dhe <strong>ISO 11040-4<\/strong><\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-5e16d2dd uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-icon-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 512 512\"><path d=\"M0 256C0 114.6 114.6 0 256 0C397.4 0 512 114.6 512 256C512 397.4 397.4 512 256 512C114.6 512 0 397.4 0 256zM371.8 211.8C382.7 200.9 382.7 183.1 371.8 172.2C360.9 161.3 343.1 161.3 332.2 172.2L224 280.4L179.8 236.2C168.9 225.3 151.1 225.3 140.2 236.2C129.3 247.1 129.3 264.9 140.2 275.8L204.2 339.8C215.1 350.7 232.9 350.7 243.8 339.8L371.8 211.8z\"><\/path><\/svg><\/div><div class=\"uagb-ifb-title-wrap\"><h3 class=\"uagb-ifb-title\"><strong><strong>Rrezik i reduktuar<\/strong><\/strong><\/h3><\/div><p class=\"uagb-ifb-desc\">d\u00ebshtimeve t\u00eb lidhura me rrjedhjet<\/p><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-df09b0b6\">\n<div class=\"wp-block-uagb-info-box uagb-block-eefea7f7 uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-icon-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 512 512\"><path d=\"M0 256C0 114.6 114.6 0 256 0C397.4 0 512 114.6 512 256C512 397.4 397.4 512 256 512C114.6 512 0 397.4 0 256zM371.8 211.8C382.7 200.9 382.7 183.1 371.8 172.2C360.9 161.3 343.1 161.3 332.2 172.2L224 280.4L179.8 236.2C168.9 225.3 151.1 225.3 140.2 236.2C129.3 247.1 129.3 264.9 140.2 275.8L204.2 339.8C215.1 350.7 232.9 350.7 243.8 339.8L371.8 211.8z\"><\/path><\/svg><\/div><div class=\"uagb-ifb-title-wrap\"><h3 class=\"uagb-ifb-title\"><strong><strong>Siguri e p\u00ebrmir\u00ebsuar<\/strong><\/strong><\/h3><\/div><p class=\"uagb-ifb-desc\">dhe sigurimi i sterilitetit<\/p><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-368e7558 uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-icon-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 512 512\"><path d=\"M0 256C0 114.6 114.6 0 256 0C397.4 0 512 114.6 512 256C512 397.4 397.4 512 256 512C114.6 512 0 397.4 0 256zM371.8 211.8C382.7 200.9 382.7 183.1 371.8 172.2C360.9 161.3 343.1 161.3 332.2 172.2L224 280.4L179.8 236.2C168.9 225.3 151.1 225.3 140.2 236.2C129.3 247.1 129.3 264.9 140.2 275.8L204.2 339.8C215.1 350.7 232.9 350.7 243.8 339.8L371.8 211.8z\"><\/path><\/svg><\/div><div class=\"uagb-ifb-title-wrap\"><h3 class=\"uagb-ifb-title\"><strong><strong><strong>Reputacion i p\u00ebrmir\u00ebsuar<\/strong><\/strong><\/strong><\/h3><\/div><p class=\"uagb-ifb-desc\">p\u00ebr produkte mjek\u00ebsore t\u00eb besueshme dhe t\u00eb sigurta<\/p><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-7979618b uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-icon-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 512 512\"><path d=\"M0 256C0 114.6 114.6 0 256 0C397.4 0 512 114.6 512 256C512 397.4 397.4 512 256 512C114.6 512 0 397.4 0 256zM371.8 211.8C382.7 200.9 382.7 183.1 371.8 172.2C360.9 161.3 343.1 161.3 332.2 172.2L224 280.4L179.8 236.2C168.9 225.3 151.1 225.3 140.2 236.2C129.3 247.1 129.3 264.9 140.2 275.8L204.2 339.8C215.1 350.7 232.9 350.7 243.8 339.8L371.8 211.8z\"><\/path><\/svg><\/div><div class=\"uagb-ifb-title-wrap\"><h3 class=\"uagb-ifb-title\"><strong><strong>Matje e sakt\u00eb<\/strong><\/strong><\/h3><\/div><p class=\"uagb-ifb-desc\">e integritetit t\u00eb shiring\u00ebs n\u00eb kushte realiste<\/p><\/div><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-c2pfwf1o alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-hnrb8wm3\">\n<div class=\"wp-block-uagb-info-box uagb-block-ye7ifu7u uagb-infobox__content-wrap  uagb-infobox-icon-above-title uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><h2 class=\"uagb-ifb-title\">Na kontaktoni<\/h2><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-info-box uagb-block-il5m7vwo uagb-infobox__content-wrap  uagb-infobox-icon-left uagb-infobox-left uagb-infobox-image-valign-top\"><div class=\"uagb-ifb-icon-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 384 512\"><path d=\"M168.3 499.2C116.1 435 0 279.4 0 192C0 85.96 85.96 0 192 0C298 0 384 85.96 384 192C384 279.4 267 435 215.7 499.2C203.4 514.5 180.6 514.5 168.3 499.2H168.3zM192 256C227.3 256 256 227.3 256 192C256 156.7 227.3 128 192 128C156.7 128 128 156.7 128 192C128 227.3 156.7 256 192 256z\"><\/path><\/svg><\/div><div class=\"uagb-ifb-content\"><div class=\"uagb-ifb-title-wrap\"><p class=\"uagb-ifb-title\">Adresa<\/p><\/div><p class=\"uagb-ifb-desc\">Nr. 5577, Gongyebei Rd, Licheng Dist. 250109, Jinan, Shandong, Kin\u00eb<\/p><div class=\"uagb-ifb-separator\"><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-uagb-icon-list uagb-block-1wyzlgvm\"><div class=\"uagb-icon-list__wrap\">\n<div class=\"wp-block-uagb-icon-list-child uagb-block-jpmi8ddm\"><span class=\"uagb-icon-list__source-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 512 512\"><path d=\"M464 64C490.5 64 512 85.49 512 112C512 127.1 504.9 141.3 492.8 150.4L275.2 313.6C263.8 322.1 248.2 322.1 236.8 313.6L19.2 150.4C7.113 141.3 0 127.1 0 112C0 85.49 21.49 64 48 64H464zM217.6 339.2C240.4 356.3 271.6 356.3 294.4 339.2L512 176V384C512 419.3 483.3 448 448 448H64C28.65 448 0 419.3 0 384V176L217.6 339.2z\"><\/path><\/svg><\/span><span class=\"uagb-icon-list__label\">marketing@celtec.cn<\/span><\/div>\n\n\n\n<div class=\"wp-block-uagb-icon-list-child uagb-block-l8jhl5ea\"><span class=\"uagb-icon-list__source-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 512 512\"><path d=\"M511.2 387l-23.25 100.8c-3.266 14.25-15.79 24.22-30.46 24.22C205.2 512 0 306.8 0 54.5c0-14.66 9.969-27.2 24.22-30.45l100.8-23.25C139.7-2.602 154.7 5.018 160.8 18.92l46.52 108.5c5.438 12.78 1.77 27.67-8.98 36.45L144.5 207.1c33.98 69.22 90.26 125.5 159.5 159.5l44.08-53.8c8.688-10.78 23.69-14.51 36.47-8.975l108.5 46.51C506.1 357.2 514.6 372.4 511.2 387z\"><\/path><\/svg><\/span><span class=\"uagb-icon-list__label\">+86 185 6001 3985<\/span><\/div>\n\n\n\n<div class=\"wp-block-uagb-icon-list-child uagb-block-rsykczrf\"><span class=\"uagb-icon-list__source-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 512 512\"><path d=\"M256 512C114.6 512 0 397.4 0 256C0 114.6 114.6 0 256 0C397.4 0 512 114.6 512 256C512 397.4 397.4 512 256 512zM232 256C232 264 236 271.5 242.7 275.1L338.7 339.1C349.7 347.3 364.6 344.3 371.1 333.3C379.3 322.3 376.3 307.4 365.3 300L280 243.2V120C280 106.7 269.3 96 255.1 96C242.7 96 231.1 106.7 231.1 120L232 256z\"><\/path><\/svg><\/span><span class=\"uagb-icon-list__label\">08:00 - 06:00 (GMT + 8)<\/span><\/div>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-contact-form-7-contact-form-selector\">\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f1729-o1\" lang=\"en-GB\" dir=\"ltr\" data-wpcf7-id=\"1729\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/sq\/wp-json\/wp\/v2\/posts\/4129#wpcf7-f1729-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Formulari i kontaktit\" novalidate=\"novalidate\" data-status=\"init\" data-trp-original-action=\"\/sq\/wp-json\/wp\/v2\/posts\/4129#wpcf7-f1729-o1\">\n<div style=\"display: none;\">\n<input type=\"hidden\" name=\"_wpcf7\" value=\"1729\" \/>\n<input type=\"hidden\" name=\"_wpcf7_version\" value=\"6.0.6\" \/>\n<input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_GB\" \/>\n<input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f1729-o1\" \/>\n<input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/>\n<input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<input type=\"hidden\" name=\"_wpcf7_recaptcha_response\" value=\"\" \/>\n<\/div>\n<p><label> Emri yt<br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" autocomplete=\"name\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"text\" name=\"your-name\" \/><\/span> <\/label>\n<\/p>\n<p><label> Emaili juaj<br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" autocomplete=\"email\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"email\" name=\"your-email\" \/><\/span> <\/label>\n<\/p>\n<p><label> L\u00ebnd\u00eb<br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-subject\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"text\" name=\"your-subject\" \/><\/span> <\/label>\n<\/p>\n<p><label> Mesazhi juaj (opsional)<br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"10\" maxlength=\"2000\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" name=\"your-message\"><\/textarea><\/span> <\/label>\n<\/p>\n<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Paraqisni\" \/>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<input type=\"hidden\" name=\"trp-form-language\" value=\"sq\"\/><\/form>\n<\/div>\n<\/div>\n<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>T\u00eb <strong>Testuesi i rrjedhjes s\u00eb shiring\u00ebs<\/strong> \u00ebsht\u00eb nj\u00eb mjet thelb\u00ebsor p\u00ebr kontrollin e cil\u00ebsis\u00eb n\u00eb prodhimin e pajisjeve mjek\u00ebsore. Sigurimi q\u00eb shiringat t\u00eb mos ken\u00eb rrjedhje \u00ebsht\u00eb jetik p\u00ebr sigurin\u00eb e pacientit dhe besueshm\u00ebrin\u00eb e produktit. Ky artikull analizon thell\u00ebsisht <strong>Testi i rrjedhjes s\u00eb l\u00ebngut<\/strong> p\u00ebrpunon dhe thekson r\u00ebnd\u00ebsin\u00eb e standardeve si <strong>ISO 7886-1<\/strong> dhe <strong>ISO 11040-4<\/strong> p\u00ebr t'ju ndihmuar t\u00eb kuptoni se si t\u00eb vler\u00ebsoni n\u00eb m\u00ebnyr\u00eb efektive performanc\u00ebn e shiring\u00ebs.<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","footnotes":""},"categories":[1],"tags":[108],"class_list":["post-4129","post","type-post","status-publish","format-standard","hentry","category-test-method","tag-iso-7886-1"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Syringe Leak Tester - Liquid Leakage Test Method - Leakage Tester<\/title>\n<meta name=\"description\" content=\"Discover the syringe leak tester, its liquid leakage test process, and ISO 7886-1 and ISO 11040-4 standards for reliable quality control.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.leakagetester.com\/sq\/syringe-leak-tester-liquid-leakage-test-method\/\" \/>\n<meta property=\"og:locale\" content=\"sq_AL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Syringe Leak Tester - Liquid Leakage Test Method\" \/>\n<meta property=\"og:description\" content=\"Discover the syringe leak tester, its liquid leakage test process, and ISO 7886-1 and ISO 11040-4 standards for reliable quality control.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.leakagetester.com\/sq\/syringe-leak-tester-liquid-leakage-test-method\/\" \/>\n<meta property=\"og:site_name\" content=\"Leakage Tester\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/cellinstruments\/\" \/>\n<meta property=\"article:published_time\" content=\"2025-06-04T03:01:02+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-14T03:19:51+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-01.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"400\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"leakagetester\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Syringe Leak Tester - Liquid Leakage Test Method\" \/>\n<meta name=\"twitter:description\" content=\"Discover the syringe leak tester, its liquid leakage test process, and ISO 7886-1 and ISO 11040-4 standards for reliable quality control.\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-01.webp\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"leakagetester\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minuta\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/\"},\"author\":{\"name\":\"leakagetester\",\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/person\/96aac8c7a484e71f92e270fcd275b658\"},\"headline\":\"SPPT-01 Syringe Positive Pressure Tightness Tester\",\"datePublished\":\"2025-06-04T03:01:02+00:00\",\"dateModified\":\"2025-11-14T03:19:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/\"},\"wordCount\":560,\"publisher\":{\"@id\":\"https:\/\/www.leakagetester.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-01-1.webp\",\"keywords\":[\"ISO 7886-1\"],\"articleSection\":[\"Test Method\"],\"inLanguage\":\"sq\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/\",\"url\":\"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/\",\"name\":\"Syringe Leak Tester - Liquid Leakage Test Method - Leakage Tester\",\"isPartOf\":{\"@id\":\"https:\/\/www.leakagetester.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-01-1.webp\",\"datePublished\":\"2025-06-04T03:01:02+00:00\",\"dateModified\":\"2025-11-14T03:19:51+00:00\",\"description\":\"Discover the syringe leak tester, its liquid leakage test process, and ISO 7886-1 and ISO 11040-4 standards for reliable quality control.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/#breadcrumb\"},\"inLanguage\":\"sq\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"sq\",\"@id\":\"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/#primaryimage\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-01-1.webp\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-01-1.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.leakagetester.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"SPPT-01 Syringe Positive Pressure Tightness Tester\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.leakagetester.com\/#website\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"name\":\"Leakage Testing Solutions\",\"description\":\"CELL INSTRUMENTS CO., LTD.\",\"publisher\":{\"@id\":\"https:\/\/www.leakagetester.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.leakagetester.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sq\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.leakagetester.com\/#organization\",\"name\":\"Cell Instruments Co., Ltd.\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sq\",\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"width\":1269,\"height\":342,\"caption\":\"Cell Instruments Co., Ltd.\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/cellinstruments\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/person\/96aac8c7a484e71f92e270fcd275b658\",\"name\":\"leakagetester\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sq\",\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/34ef90e19f505d6d189c641e05c0d8dbc46c91aba4d349f9b234306c852bed3e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/34ef90e19f505d6d189c641e05c0d8dbc46c91aba4d349f9b234306c852bed3e?s=96&d=mm&r=g\",\"caption\":\"leakagetester\"},\"url\":\"https:\/\/www.leakagetester.com\/sq\/author\/leakagetester\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Testues i rrjedhjeve t\u00eb shiring\u00ebs - Metoda e testimit t\u00eb rrjedhjes s\u00eb l\u00ebngut - Testues i rrjedhjes","description":"Zbuloni testuesin e rrjedhjeve me shiring\u00eb, procesin e tij t\u00eb testimit t\u00eb rrjedhjes s\u00eb l\u00ebngut, dhe standardet ISO 7886-1 dhe ISO 11040-4 p\u00ebr nj\u00eb kontroll t\u00eb besuesh\u00ebm t\u00eb cil\u00ebsis\u00eb.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.leakagetester.com\/sq\/syringe-leak-tester-liquid-leakage-test-method\/","og_locale":"sq_AL","og_type":"article","og_title":"Syringe Leak Tester - Liquid Leakage Test Method","og_description":"Discover the syringe leak tester, its liquid leakage test process, and ISO 7886-1 and ISO 11040-4 standards for reliable quality control.","og_url":"https:\/\/www.leakagetester.com\/sq\/syringe-leak-tester-liquid-leakage-test-method\/","og_site_name":"Leakage Tester","article_publisher":"https:\/\/www.facebook.com\/cellinstruments\/","article_published_time":"2025-06-04T03:01:02+00:00","article_modified_time":"2025-11-14T03:19:51+00:00","og_image":[{"width":400,"height":600,"url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-01.webp","type":"image\/webp"}],"author":"leakagetester","twitter_card":"summary_large_image","twitter_title":"Syringe Leak Tester - Liquid Leakage Test Method","twitter_description":"Discover the syringe leak tester, its liquid leakage test process, and ISO 7886-1 and ISO 11040-4 standards for reliable quality control.","twitter_image":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-01.webp","twitter_misc":{"Written by":"leakagetester","Est. reading time":"4 minuta"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/#article","isPartOf":{"@id":"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/"},"author":{"name":"leakagetester","@id":"https:\/\/www.leakagetester.com\/#\/schema\/person\/96aac8c7a484e71f92e270fcd275b658"},"headline":"SPPT-01 Syringe Positive Pressure Tightness Tester","datePublished":"2025-06-04T03:01:02+00:00","dateModified":"2025-11-14T03:19:51+00:00","mainEntityOfPage":{"@id":"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/"},"wordCount":560,"publisher":{"@id":"https:\/\/www.leakagetester.com\/#organization"},"image":{"@id":"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/#primaryimage"},"thumbnailUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-01-1.webp","keywords":["ISO 7886-1"],"articleSection":["Test Method"],"inLanguage":"sq"},{"@type":"WebPage","@id":"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/","url":"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/","name":"Testues i rrjedhjeve t\u00eb shiring\u00ebs - Metoda e testimit t\u00eb rrjedhjes s\u00eb l\u00ebngut - Testues i rrjedhjes","isPartOf":{"@id":"https:\/\/www.leakagetester.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/#primaryimage"},"image":{"@id":"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/#primaryimage"},"thumbnailUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-01-1.webp","datePublished":"2025-06-04T03:01:02+00:00","dateModified":"2025-11-14T03:19:51+00:00","description":"Zbuloni testuesin e rrjedhjeve me shiring\u00eb, procesin e tij t\u00eb testimit t\u00eb rrjedhjes s\u00eb l\u00ebngut, dhe standardet ISO 7886-1 dhe ISO 11040-4 p\u00ebr nj\u00eb kontroll t\u00eb besuesh\u00ebm t\u00eb cil\u00ebsis\u00eb.","breadcrumb":{"@id":"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/#breadcrumb"},"inLanguage":"sq","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/"]}]},{"@type":"ImageObject","inLanguage":"sq","@id":"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/#primaryimage","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-01-1.webp","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/06\/Syringe-Leak-Tester-Liquid-Leakage-Test-Method-01-1.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.leakagetester.com\/syringe-leak-tester-liquid-leakage-test-method\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.leakagetester.com\/"},{"@type":"ListItem","position":2,"name":"SPPT-01 Syringe Positive Pressure Tightness Tester"}]},{"@type":"WebSite","@id":"https:\/\/www.leakagetester.com\/#website","url":"https:\/\/www.leakagetester.com\/","name":"Zgjidhjet e testimit t\u00eb rrjedhjeve","description":"INSTRUMENTET CELL CO, LTD.","publisher":{"@id":"https:\/\/www.leakagetester.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.leakagetester.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sq"},{"@type":"Organization","@id":"https:\/\/www.leakagetester.com\/#organization","name":"Cell Instruments Co., Ltd.","url":"https:\/\/www.leakagetester.com\/","logo":{"@type":"ImageObject","inLanguage":"sq","@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","width":1269,"height":342,"caption":"Cell Instruments Co., Ltd."},"image":{"@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/cellinstruments\/"]},{"@type":"Person","@id":"https:\/\/www.leakagetester.com\/#\/schema\/person\/96aac8c7a484e71f92e270fcd275b658","name":"kontrollues i rrjedhjeve","image":{"@type":"ImageObject","inLanguage":"sq","@id":"https:\/\/www.leakagetester.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/34ef90e19f505d6d189c641e05c0d8dbc46c91aba4d349f9b234306c852bed3e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/34ef90e19f505d6d189c641e05c0d8dbc46c91aba4d349f9b234306c852bed3e?s=96&d=mm&r=g","caption":"leakagetester"},"url":"https:\/\/www.leakagetester.com\/sq\/author\/leakagetester\/"}]}},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"leakagetester","author_link":"https:\/\/www.leakagetester.com\/sq\/author\/leakagetester\/"},"uagb_comment_info":0,"uagb_excerpt":"The syringe leak tester is an essential tool for quality control in medical device manufacturing. Ensuring that syringes remain leak-free is vital for patient safety and product reliability. This article delves into the liquid leakage test process and highlights the importance of standards like ISO 7886-1 and ISO 11040-4 to help you understand how to&hellip;","_links":{"self":[{"href":"https:\/\/www.leakagetester.com\/sq\/wp-json\/wp\/v2\/posts\/4129","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.leakagetester.com\/sq\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.leakagetester.com\/sq\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/sq\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/sq\/wp-json\/wp\/v2\/comments?post=4129"}],"version-history":[{"count":0,"href":"https:\/\/www.leakagetester.com\/sq\/wp-json\/wp\/v2\/posts\/4129\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.leakagetester.com\/sq\/wp-json\/wp\/v2\/media?parent=4129"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.leakagetester.com\/sq\/wp-json\/wp\/v2\/categories?post=4129"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.leakagetester.com\/sq\/wp-json\/wp\/v2\/tags?post=4129"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}