{"id":4445,"date":"2025-12-11T15:08:25","date_gmt":"2025-12-11T07:08:25","guid":{"rendered":"https:\/\/www.leakagetester.com\/?page_id=4445"},"modified":"2025-12-11T15:28:48","modified_gmt":"2025-12-11T07:28:48","slug":"astm-e493","status":"publish","type":"page","link":"https:\/\/www.leakagetester.com\/tr\/standards\/astm-e493\/","title":{"rendered":"ASTM E493"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"4445\" class=\"elementor elementor-4445\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-40854497 e-con-full e-flex e-con e-parent\" data-id=\"40854497\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-7b6e2650 e-con-full e-flex e-con e-child\" data-id=\"7b6e2650\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1ed62b75 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"1ed62b75\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ASTM E493<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-649c5ca3 e-con-full e-flex e-con e-child\" data-id=\"649c5ca3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-528d414f elementor-widget elementor-widget-heading\" data-id=\"528d414f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h5 class=\"elementor-heading-title elementor-size-default\">K\u00fctle Spektrometresi S\u0131z\u0131nt\u0131 Dedekt\u00f6r\u00fcn\u00fcn \u0130\u00e7ten D\u0131\u015fa Test Modunda Kullan\u0131ld\u0131\u011f\u0131 S\u0131z\u0131nt\u0131lar i\u00e7in Standart Uygulama<\/h5>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4227f1f3 elementor-tablet-align-center elementor-mobile-align-center elementor-widget__width-inherit elementor-invisible elementor-widget elementor-widget-button\" data-id=\"4227f1f3\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;,&quot;_animation_delay&quot;:200}\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/tr\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Teklif \u0130steyin<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7f37671f e-flex e-con-boxed e-con e-parent\" data-id=\"7f37671f\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-7479e6a9 e-con-full e-flex e-con e-child\" data-id=\"7479e6a9\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c1f01b8 elementor-widget elementor-widget-heading\" data-id=\"2c1f01b8\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Standart \u00d6zet<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a7ff4e2 elementor-widget elementor-widget-text-editor\" data-id=\"a7ff4e2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"424\" data-end=\"1049\">ASTM E493, i\u00e7ten d\u0131\u015fa modunda bir k\u00fctle spektrometresi s\u0131z\u0131nt\u0131 detekt\u00f6r\u00fc kullanarak s\u0131zd\u0131rmaz bile\u015fenlerdeki s\u0131z\u0131nt\u0131y\u0131 de\u011ferlendirmek i\u00e7in yap\u0131land\u0131r\u0131lm\u0131\u015f bir uygulamay\u0131 tan\u0131mlar. Mikroelektronik, t\u0131bbi cihazlar ve hassas enstr\u00fcmantasyon gibi end\u00fcstriler, hermetik paketlerin b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fc do\u011frulamak i\u00e7in bu y\u00f6nteme g\u00fcvenmektedir. M\u00fchendisler, ASTM E493 ilkelerini uygulayarak ince s\u0131z\u0131nt\u0131lar\u0131 belirleme, ger\u00e7ek s\u0131z\u0131nt\u0131 oranlar\u0131n\u0131 hesaplama ve \u00fcr\u00fcn g\u00fcvenilirli\u011fini koruma becerisi kazan\u0131rlar.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-58d7dfdf e-con-full e-flex e-con e-child\" data-id=\"58d7dfdf\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4aba77f5 elementor-widget elementor-widget-image\" data-id=\"4aba77f5\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.astm.org\/d3078-02r21e01.html\" target=\"_blank\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"200\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp\" class=\"attachment-medium size-medium wp-image-4448\" alt=\"ASTM E493\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp 600w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493-18x6.webp 18w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-38d9a2dc e-flex e-con-boxed e-con e-parent\" data-id=\"38d9a2dc\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-22b1040c e-con-full e-flex e-con e-child\" data-id=\"22b1040c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c1b4a01 elementor-widget elementor-widget-heading\" data-id=\"2c1b4a01\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Standart A\u00e7\u0131klama<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2dbe846b elementor-widget elementor-widget-text-editor\" data-id=\"2dbe846b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1686\" data-end=\"2154\">ASTM E493, yar\u0131 iletkenler, r\u00f6leler, piroteknik bile\u015fenler ve y\u00fcksek g\u00fcvenilirlikli sens\u00f6rler dahil olmak \u00fczere testten \u00f6nce m\u00fch\u00fcrlenen cihazlar\u0131 ele al\u0131r. Standart, test maddesinin \u00f6l\u00e7\u00fcm s\u0131ras\u0131nda bilinen veya hesaplanabilir bir i\u00e7 bas\u0131n\u00e7ta helyum i\u00e7ermesini gerektirir. Par\u00e7a m\u00fch\u00fcrlenmeden \u00f6nce doldurulam\u0131yorsa, y\u00f6ntem helyumu kontroll\u00fc bir bombalama i\u015flemi yoluyla verir. Bu yakla\u015f\u0131m, cihaz duvar\u0131ndan ge\u00e7en en k\u00fc\u00e7\u00fck yolun bile tespit edilebilmesini sa\u011flar.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-346b4bef e-con-full e-flex e-con e-child\" data-id=\"346b4bef\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8704851 elementor-widget elementor-widget-text-editor\" data-id=\"8704851\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2156\" data-end=\"2336\">Uygulama iki temel tekni\u011fin ana hatlar\u0131n\u0131 \u00e7izmektedir:<\/p><ul><li data-start=\"2156\" data-end=\"2336\"><strong data-start=\"2204\" data-end=\"2221\">Test Y\u00f6ntemi A<\/strong> izleyici gaz\u0131 vermek i\u00e7in helyum bombas\u0131 kullan\u0131r.<\/li><li data-start=\"2156\" data-end=\"2336\"><strong data-start=\"2273\" data-end=\"2290\">Test Y\u00f6ntemi B<\/strong> m\u00fch\u00fcrlemeden \u00f6nce helyum ile \u00f6n dolum kullan\u0131r.<\/li><\/ul><p data-start=\"2338\" data-end=\"2533\">Her iki durumda da, par\u00e7a daha sonra bir k\u00fctle spektrometresi s\u0131z\u0131nt\u0131 dedekt\u00f6r\u00fcne ba\u011fl\u0131 bo\u015falt\u0131lm\u0131\u015f bir muhafazaya girer. Bir s\u0131z\u0131nt\u0131 oldu\u011funda, dedekt\u00f6r helyum ak\u0131\u015f\u0131n\u0131 \u00f6l\u00e7er ve belirtilen bir oran verir.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3ae6b8a e-flex e-con-boxed e-con e-parent\" data-id=\"3ae6b8a\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-8f24e53 e-con-full e-flex e-con e-child\" data-id=\"8f24e53\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-6905cde e-con-full e-flex e-con e-child\" data-id=\"6905cde\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-61e733b elementor-widget elementor-widget-heading\" data-id=\"61e733b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test Y\u00f6ntemi A: Bombalama Prosed\u00fcr\u00fc<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5930041 elementor-widget elementor-widget-heading\" data-id=\"5930041\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">Bombalama ile test par\u00e7as\u0131 haz\u0131rlama<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a52d762 e-con-full e-flex e-con e-child\" data-id=\"a52d762\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6e9e0cd elementor-widget elementor-widget-text-editor\" data-id=\"6e9e0cd\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2578\" data-end=\"2923\">Bombalama, do\u011frudan dahili gaz dolumu m\u00fcmk\u00fcn olmad\u0131\u011f\u0131nda uygulan\u0131r. M\u00fch\u00fcrl\u00fc bile\u015fenler \u00f6nceden belirlenmi\u015f bir s\u00fcre boyunca bir helyum bas\u0131n\u00e7 odas\u0131nda kal\u0131r. Bombalama s\u00fcresi, bas\u0131n\u00e7 ve bekleme s\u00fcresi hassasiyeti do\u011frudan etkiler. Yetersiz kontrol tutars\u0131z sonu\u00e7lara yol a\u00e7abilir, bu nedenle en iyi uygulama bu de\u011ferlerin partiler aras\u0131nda standartla\u015ft\u0131r\u0131lmas\u0131n\u0131 i\u00e7erir.<\/p><p data-start=\"2925\" data-end=\"3330\">Bombalamadan sonra operat\u00f6rler azot y\u0131kama veya kontroll\u00fc kurutma yoluyla y\u00fczey helyumunu uzakla\u015ft\u0131rmal\u0131d\u0131r. Bu ad\u0131m, emilen helyumun dedekt\u00f6rde arka plan sinyalleri \u00fcretmesini \u00f6nler. Par\u00e7alar temizlendikten sonra \u00f6l\u00e7\u00fcm i\u00e7in test muhafazas\u0131na yerle\u015ftirilir. M\u00fchendisler, ger\u00e7ek s\u0131z\u0131nt\u0131 oran\u0131n\u0131n hesaplanmas\u0131n\u0131 etkileyen belirtilen s\u0131z\u0131nt\u0131 oran\u0131n\u0131 ve bombalama ile test aras\u0131nda ge\u00e7en s\u00fcreyi kaydeder.<\/p><p data-start=\"3332\" data-end=\"3367\">Standart denklemi sa\u011flar:<\/p><p><img decoding=\"async\" class=\"size-full wp-image-4449 aligncenter\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493-Test-Method-A.webp\" alt=\"ASTM E493 Test Y\u00f6ntemi A\" width=\"302\" height=\"65\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493-Test-Method-A.webp 302w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493-Test-Method-A-18x4.webp 18w\" sizes=\"(max-width: 302px) 100vw, 302px\" \/><\/p><p data-start=\"3437\" data-end=\"3581\">Bu ili\u015fki, hesaplanan ger\u00e7ek s\u0131z\u0131nt\u0131 oran\u0131n\u0131n muhafazakar kalmas\u0131n\u0131 sa\u011flar ve kritik bile\u015fenler i\u00e7in yerle\u015fik bir g\u00fcvenlik fakt\u00f6r\u00fc i\u00e7erir.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7b391d0 e-flex e-con-boxed e-con e-parent\" data-id=\"7b391d0\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-b327d60 e-con-full e-flex e-con e-child\" data-id=\"b327d60\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-91fcac1 elementor-widget elementor-widget-text-editor\" data-id=\"91fcac1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3631\" data-end=\"3932\">Cihaz m\u00fch\u00fcrlenmeden \u00f6nce helyumla doldurulabildi\u011finde, Y\u00f6ntem B daha do\u011frudan bir i\u015f ak\u0131\u015f\u0131 sa\u011flar. Par\u00e7a bilinen bir bas\u0131n\u00e7ta doldurulur, m\u00fch\u00fcrlenir ve Y\u00f6ntem A ile ayn\u0131 i\u00e7ten d\u0131\u015fa ko\u015fullar alt\u0131nda test edilir. Bombalama ger\u00e7ekle\u015fmedi\u011finden, hesaplama \u00f6nceki denklemin ilk parantezini kald\u0131r\u0131r:<\/p>\n<p data-start=\"3631\" data-end=\"3932\"><img decoding=\"async\" class=\"size-full wp-image-4450 aligncenter\" src=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E439-Method-B.webp\" alt=\"ASTM E439 Y\u00f6ntem B\" width=\"150\" height=\"58\" srcset=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E439-Method-B.webp 150w, https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E439-Method-B-18x7.webp 18w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/p>\n<p data-start=\"3974\" data-end=\"4085\">\u0130\u00e7 bas\u0131n\u00e7 bilindi\u011finden, Y\u00f6ntem B genellikle daha s\u0131k\u0131 kalite kontrol\u00fcn\u00fc ve daha h\u0131zl\u0131 d\u00f6ng\u00fc s\u00fcrelerini destekler.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d9a5245 e-con-full e-flex e-con e-child\" data-id=\"d9a5245\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-6cf77b9 e-con-full e-flex e-con e-child\" data-id=\"6cf77b9\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-99feec5 elementor-widget elementor-widget-heading\" data-id=\"99feec5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test Y\u00f6ntemi B: Helyum ile \u00d6n Dolum<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2a8993b elementor-widget elementor-widget-heading\" data-id=\"2a8993b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">\u00f6n dolum ile est par\u00e7a haz\u0131rl\u0131\u011f\u0131<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-897aaf5 e-flex e-con-boxed e-con e-parent\" data-id=\"897aaf5\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-23d08cc elementor-widget elementor-widget-heading\" data-id=\"23d08cc\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Kalite ve G\u00fcvenilirlik i\u00e7in \u00d6nem<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-48e4aa6 elementor-widget elementor-widget-text-editor\" data-id=\"48e4aa6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4138\" data-end=\"4459\">\u00dcreticiler, hermetik olarak kapat\u0131lm\u0131\u015f cihazlar\u0131n uzun s\u00fcreli hava, su buhar\u0131 ve kirletici giri\u015fini \u00f6nledi\u011fini do\u011frulamak i\u00e7in ASTM E493'\u00fc kullanmaktad\u0131r. Minimum s\u0131z\u0131nt\u0131 bile mikroelektronikleri veya hassas t\u0131bbi bile\u015fenleri zaman i\u00e7inde bozabilir. Bu y\u00f6ntemin do\u011fru \u015fekilde uygulanmas\u0131, a\u015fa\u011f\u0131 ak\u0131\u015f performans\u0131n\u0131 korur ve saha ar\u0131zalar\u0131n\u0131 azalt\u0131r.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c6c9624 elementor-widget elementor-widget-heading\" data-id=\"c6c9624\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Giri\u015fimler ve \u0130yi Uygulama<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-95095df elementor-widget elementor-widget-text-editor\" data-id=\"95095df\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4855\" data-end=\"5327\">Y\u00fczey kaplamalar\u0131, kir, polimerik malzemeler ve p\u00fcr\u00fczl\u00fc dokular bombalama s\u0131ras\u0131nda helyumu tutabilir. \u00d6nlem al\u0131nmazsa bu parazit kaynaklar\u0131 arka plan okumalar\u0131n\u0131 y\u00fckseltebilir ve ger\u00e7ek s\u0131z\u0131nt\u0131lar\u0131 gizleyebilir. Azotla y\u0131kama veya kontroll\u00fc \u0131s\u0131tma genellikle bu endi\u015feyi azalt\u0131r. \u00c7ok b\u00fcy\u00fck s\u0131z\u0131nt\u0131lar veya \u00e7ok k\u00fc\u00e7\u00fck i\u00e7 hacimler s\u00f6z konusu oldu\u011funda, helyum testten \u00f6nce ka\u00e7abilir, bu da kabarc\u0131k testlerini veya hazneden \u00e7\u0131kar\u0131ld\u0131ktan hemen sonra alternatif b\u00fcy\u00fck s\u0131z\u0131nt\u0131 y\u00f6ntemlerini gerektirir.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3a2b679a e-flex e-con-boxed e-con e-parent\" data-id=\"3a2b679a\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-38014124 elementor-widget elementor-widget-heading\" data-id=\"38014124\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">G\u00fcvenilir ka\u00e7ak tespit ekipman\u0131 m\u0131 ar\u0131yorsunuz?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-53b530f2 elementor-widget elementor-widget-text-editor\" data-id=\"53b530f2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00a0Kalite kontrol s\u00fcre\u00e7lerinizi son teknoloji ekipmanlarla optimize etme f\u0131rsat\u0131n\u0131 ka\u00e7\u0131rmay\u0131n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d0c06b6 elementor-mobile-align-center elementor-align-center elementor-widget elementor-widget-button\" data-id=\"5d0c06b6\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/tr\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Bize Ula\u015f\u0131n<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ASTM E493 \u0130\u00e7ten D\u0131\u015fa Test Modunda K\u00fctle Spektrometresi Ka\u00e7ak Dedekt\u00f6r\u00fc Kullanarak S\u0131z\u0131nt\u0131lar i\u00e7in Standart Uygulama Teklif \u0130ste Standart \u00d6zet ASTM E493, i\u00e7ten d\u0131\u015fa modunda bir k\u00fctle spektrometresi ka\u00e7ak dedekt\u00f6r\u00fc kullanarak kapal\u0131 bile\u015fenlerdeki s\u0131z\u0131nt\u0131y\u0131 de\u011ferlendirmek i\u00e7in yap\u0131land\u0131r\u0131lm\u0131\u015f bir uygulama tan\u0131mlar. Mikroelektronik, t\u0131bbi cihazlar ve hassas enstr\u00fcmantasyon gibi end\u00fcstriler [...]","protected":false},"author":2,"featured_media":0,"parent":2112,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-4445","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ASTM E493 - Helium &amp; Mass Spectrometer Leak Testing<\/title>\n<meta name=\"description\" content=\"ASTM E493 explains mass spectrometer inside-out leak testing for sealed devices. Learn methods, sensitivity, helium bombing, and how Cell Instruments supports precision leak testing.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.leakagetester.com\/tr\/standards\/astm-e493\/\" \/>\n<meta property=\"og:locale\" content=\"tr_TR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ASTM E493 - Helium &amp; Mass Spectrometer Leak Testing\" \/>\n<meta property=\"og:description\" content=\"ASTM E493 explains mass spectrometer inside-out leak testing for sealed devices. Learn methods, sensitivity, helium bombing, and how Cell Instruments supports precision leak testing.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.leakagetester.com\/tr\/standards\/astm-e493\/\" \/>\n<meta property=\"og:site_name\" content=\"Leakage Tester\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/cellinstruments\/\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-11T07:28:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"ASTM E493 - Helium &amp; Mass Spectrometer Leak Testing\" \/>\n<meta name=\"twitter:description\" content=\"ASTM E493 explains mass spectrometer inside-out leak testing for sealed devices. Learn methods, sensitivity, helium bombing, and how Cell Instruments supports precision leak testing.\" \/>\n<meta name=\"twitter:label1\" content=\"Tahmini okuma s\u00fcresi\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 dakika\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/astm-e493\/\",\"url\":\"https:\/\/www.leakagetester.com\/standards\/astm-e493\/\",\"name\":\"ASTM E493 - Helium & Mass Spectrometer Leak Testing\",\"isPartOf\":{\"@id\":\"https:\/\/www.leakagetester.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp\",\"datePublished\":\"2025-12-11T07:08:25+00:00\",\"dateModified\":\"2025-12-11T07:28:48+00:00\",\"description\":\"ASTM E493 explains mass spectrometer inside-out leak testing for sealed devices. Learn methods, sensitivity, helium bombing, and how Cell Instruments supports precision leak testing.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#breadcrumb\"},\"inLanguage\":\"tr\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.leakagetester.com\/standards\/astm-e493\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#primaryimage\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.leakagetester.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Standards\",\"item\":\"https:\/\/www.leakagetester.com\/standards\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ASTM E493\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.leakagetester.com\/#website\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"name\":\"Leakage Testing Solutions\",\"description\":\"CELL INSTRUMENTS CO., LTD.\",\"publisher\":{\"@id\":\"https:\/\/www.leakagetester.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.leakagetester.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"tr\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.leakagetester.com\/#organization\",\"name\":\"Cell Instruments Co., Ltd.\",\"url\":\"https:\/\/www.leakagetester.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"contentUrl\":\"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png\",\"width\":1269,\"height\":342,\"caption\":\"Cell Instruments Co., Ltd.\"},\"image\":{\"@id\":\"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/cellinstruments\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ASTM E493 - Helyum ve K\u00fctle Spektrometresi S\u0131z\u0131nt\u0131 Testi","description":"ASTM E493, kapal\u0131 cihazlar i\u00e7in k\u00fctle spektrometresi i\u00e7ten d\u0131\u015fa s\u0131z\u0131nt\u0131 testini a\u00e7\u0131klar. Y\u00f6ntemleri, hassasiyeti, helyum bombard\u0131man\u0131n\u0131 ve Cell Instruments'\u0131n hassas s\u0131z\u0131nt\u0131 testini nas\u0131l destekledi\u011fini \u00f6\u011frenin.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.leakagetester.com\/tr\/standards\/astm-e493\/","og_locale":"tr_TR","og_type":"article","og_title":"ASTM E493 - Helium & Mass Spectrometer Leak Testing","og_description":"ASTM E493 explains mass spectrometer inside-out leak testing for sealed devices. Learn methods, sensitivity, helium bombing, and how Cell Instruments supports precision leak testing.","og_url":"https:\/\/www.leakagetester.com\/tr\/standards\/astm-e493\/","og_site_name":"Leakage Tester","article_publisher":"https:\/\/www.facebook.com\/cellinstruments\/","article_modified_time":"2025-12-11T07:28:48+00:00","og_image":[{"url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_title":"ASTM E493 - Helium & Mass Spectrometer Leak Testing","twitter_description":"ASTM E493 explains mass spectrometer inside-out leak testing for sealed devices. Learn methods, sensitivity, helium bombing, and how Cell Instruments supports precision leak testing.","twitter_misc":{"Tahmini okuma s\u00fcresi":"4 dakika"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.leakagetester.com\/standards\/astm-e493\/","url":"https:\/\/www.leakagetester.com\/standards\/astm-e493\/","name":"ASTM E493 - Helyum ve K\u00fctle Spektrometresi S\u0131z\u0131nt\u0131 Testi","isPartOf":{"@id":"https:\/\/www.leakagetester.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#primaryimage"},"image":{"@id":"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#primaryimage"},"thumbnailUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp","datePublished":"2025-12-11T07:08:25+00:00","dateModified":"2025-12-11T07:28:48+00:00","description":"ASTM E493, kapal\u0131 cihazlar i\u00e7in k\u00fctle spektrometresi i\u00e7ten d\u0131\u015fa s\u0131z\u0131nt\u0131 testini a\u00e7\u0131klar. Y\u00f6ntemleri, hassasiyeti, helyum bombard\u0131man\u0131n\u0131 ve Cell Instruments'\u0131n hassas s\u0131z\u0131nt\u0131 testini nas\u0131l destekledi\u011fini \u00f6\u011frenin.","breadcrumb":{"@id":"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#breadcrumb"},"inLanguage":"tr","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.leakagetester.com\/standards\/astm-e493\/"]}]},{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#primaryimage","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2025\/12\/ASTM-E493.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.leakagetester.com\/standards\/astm-e493\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.leakagetester.com\/"},{"@type":"ListItem","position":2,"name":"Standards","item":"https:\/\/www.leakagetester.com\/standards\/"},{"@type":"ListItem","position":3,"name":"ASTM E493"}]},{"@type":"WebSite","@id":"https:\/\/www.leakagetester.com\/#website","url":"https:\/\/www.leakagetester.com\/","name":"S\u0131z\u0131nt\u0131 Testi \u00c7\u00f6z\u00fcmleri","description":"H\u00dcCRE ENSTR\u00dcMANLARI LTD.","publisher":{"@id":"https:\/\/www.leakagetester.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.leakagetester.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"tr"},{"@type":"Organization","@id":"https:\/\/www.leakagetester.com\/#organization","name":"H\u00fccre Enstr\u00fcmanlar\u0131 A.\u015e.","url":"https:\/\/www.leakagetester.com\/","logo":{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","contentUrl":"https:\/\/www.leakagetester.com\/wp-content\/uploads\/2024\/05\/EN-One-Stop-Solutions-Provider.png","width":1269,"height":342,"caption":"Cell Instruments Co., Ltd."},"image":{"@id":"https:\/\/www.leakagetester.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/cellinstruments\/"]}]}},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"leakagetester","author_link":"https:\/\/www.leakagetester.com\/tr\/author\/leakagetester\/"},"uagb_comment_info":0,"uagb_excerpt":"ASTM E493 Standard Practice for Leaks Using the Mass Spectrometer Leak Detector in the Inside-Out Testing Mode Request a Quote Standard Summary ASTM E493 defines a structured practice for evaluating leakage in sealed components using a mass spectrometer leak detector in the inside-out mode. Industries such as microelectronics, medical devices, and precision instrumentation rely on&hellip;","_links":{"self":[{"href":"https:\/\/www.leakagetester.com\/tr\/wp-json\/wp\/v2\/pages\/4445","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.leakagetester.com\/tr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.leakagetester.com\/tr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/tr\/wp-json\/wp\/v2\/comments?post=4445"}],"version-history":[{"count":0,"href":"https:\/\/www.leakagetester.com\/tr\/wp-json\/wp\/v2\/pages\/4445\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.leakagetester.com\/tr\/wp-json\/wp\/v2\/pages\/2112"}],"wp:attachment":[{"href":"https:\/\/www.leakagetester.com\/tr\/wp-json\/wp\/v2\/media?parent=4445"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}